Self-contained breathing apparatus (SCBA) is a respirator that supplies its wearer with breathing air from a source that the wearer carries, independent of the surrounding atmosphere.[1] Fire services use it because the smoke of a fire contains toxic products of unknown type and quantity, so that respiratory protection cannot be matched to a specific exposure in advance.[2] There are two designs: open-circuit SCBA, which vents exhaled breath to the atmosphere, and closed-circuit SCBA, in which the wearer rebreathes exhaled gas after the carbon dioxide has been removed.[2]

In the United States, as described in the 2008 Fire Protection Handbook, regulations and NFPA standards allowed only positive-pressure SCBA in dangerous atmospheres. The units had to be certified by the National Institute for Occupational Safety and Health (NIOSH) for at least 30 minutes of rated service.[2] Under NFPA 1981, as described there, they could weigh no more than 16 kg.[3] In strenuous fire fighting the air may last only about half the rated time.[4] The apparatus is worn with protective clothing as one ensemble, and its main practical limits are weight, heat load, limited air and the difficulty of communicating through a facepiece.[5][6][7]

Fire fighter in protective clothing wearing an open-circuit SCBA with facepiece, back-mounted composite cylinder and harness
A fire fighter wearing an open-circuit SCBA with full facepiece and back-mounted cylinder, worn together with structural fire-fighting protective clothing.

Types and operating principle

SCBA belongs to the family of atmosphere-supplying respirators, which give the user breathing air from a source independent of the ambient atmosphere.[1] The other member of this family is the supplied-air respirator (SAR), also called an airline respirator, whose air source is not designed to be carried by the user. An SAR with a continuous air line can be built into an SCBA rated for at least 30 minutes, for operations of extended duration or for extra exit time from a hazardous atmosphere.[2] Air-purifying respirators work on a different principle: they filter the surrounding air instead of replacing it.[8] For hazardous materials work, C. J. Wright (2008a) lists six types of respiratory protection, from positive-pressure SCBA down to simple particulate respirators.[9]

In an open-circuit SCBA the breathing air is stored under pressure in a cylinder and is used up as the wearer breathes. A regulator automatically reduces the high storage pressure to a usable pressure and supplies the air to the facepiece; the exhaled breath is vented to the atmosphere.[2] A closed-circuit SCBA recirculates the wearer's exhaled gas. The gas passes through a hose and a carbon dioxide absorber, then enters a breathing chamber where oxygen from a pressurised cylinder is added before it is inhaled again.[2] The oxygen can also come from chemical or liquid oxygen sources.[10] Closed-circuit sets can have a rated service life from 30 minutes to 4 hours.[2]

Two flow schematics side by side: open-circuit SCBA venting exhaled air, closed-circuit SCBA recirculating it through a CO2 absorber
Open-circuit and closed-circuit SCBA. In the open circuit, cylinder air passes a regulator to the facepiece and exhaled breath is vented; in the closed circuit, exhaled gas passes a carbon dioxide absorber, receives oxygen in a breathing chamber and is inhaled again.

Every SCBA is classified either as positive pressure, also called pressure demand, or as demand.[2] A demand unit delivers air only when the wearer's inhalation creates a negative pressure inside the facepiece. Contaminated air around the facepiece can then be drawn inside, a danger the handbook describes as significant.[2] A positive-pressure unit keeps the pressure in the facepiece above the ambient pressure during both inhalation and exhalation, which reduces inward leakage around the edge of the mask.[2][11] In the United States, the use of only positive-pressure SCBA became mandatory on 1 July 1983. Demand SCBA was prohibited for any atmosphere that was, or could become, immediately dangerous to life.[2]

Schematic pressure curves over one breath: demand SCBA dips below ambient on inhalation, positive-pressure SCBA stays above ambient
Facepiece pressure relative to the surroundings during one breath (schematic). A demand SCBA needs a negative pressure on inhalation to start the airflow, so contaminated air can leak in; a positive-pressure SCBA stays above ambient throughout.

Why fire services require SCBA

The toxicity of fire smoke comes from products of combustion whose types and quantities are not known during an incident.[2] In industry a respirator can often be selected for a known contaminant, but US respiratory protection standards recognised that this is not possible in fire fighting. Fire atmospheres are therefore classified as immediately dangerous to life and health, and SCBA is required.[2] The US Occupational Safety and Health Administration (OSHA) defines an atmosphere immediately dangerous to life and health as one that poses an immediate hazard to life or produces immediate irreversible debilitating effects on health.[12]

Carbon monoxide shows why filtering is not enough. It causes anaemic hypoxia: it competes with oxygen for the binding sites of haemoglobin, for which its affinity is about 250 times that of oxygen.[13] Particulate respirators remove irritation and make breathing seem easier, but they do nothing to protect against carbon monoxide.[8] An atmosphere-supplying respirator avoids the problem because its air does not come from the surroundings, provided that the facepiece seals.[1]

The requirement grew out of fatalities. On 17 May 1971 the NFPA adopted NFPA 19B, a standard on respiratory protective equipment for fire fighters. It prohibited filter-type canister masks for protection against the products of combustion and allowed only SCBA.[14] According to Teele (2008), this was the direct result of fire fighters dying while wearing filter-type masks. At least one court decision also found such masks inappropriate, because they did not supply uncontaminated breathing air.[14]

As described by Teele (2008), SCBA was required for all fire-fighting operations except wildland fire fighting. It was also required wherever atmospheres immediately dangerous to life or deficient in oxygen existed or were expected. Examples are CBRN (chemical, biological, radiological and nuclear) terrorism, confined space rescue, hazardous materials emergencies and some technical rescues.[15] OSHA named structural fire fighting, all hazardous materials incidents, oxygen-deficient atmospheres, sewers, confined spaces and silos.[2] At hazardous materials incidents, OSHA's rule 29 CFR 1910.120 set positive-pressure SCBA as the minimum until concentrations had been determined.[9]

The requirement continues after the fire is out. Opening concealed spaces during overhaul releases smoky, toxic and smouldering materials, and walls, ceilings and floors may contain asbestos. According to Klaene and Sanders (2008), fire fighters and investigators working inside must therefore wear full protective gear with SCBA until the building is free of smoke and airborne contaminants.[16]

Industrial fire brigades follow the same logic. According to Snyder (2008), the smoke, heat and toxic gases of a fire beyond the incipient stage make positive-pressure SCBA necessary. Protective clothing and SCBA let brigade members advance much farther into a fire area.[17] A glossary in NUREG-1805 turns this into a definition: a fire is beyond the incipient stage when thermal protective clothing or SCBA is needed.[18] Wildland fire fighting was the exception, where SCBA was judged impractical because of its weight, limited use time and cylinder recharging logistics. Wildfire smoke was considered not to be immediately dangerous to life, although its health hazards had not been quantified.[8]

Air supply and service time

Open-circuit SCBA used compressed-air cylinders at three working pressures: 2216 psi, 3500 psi and 4500 psi.[2] Converted at 1 psi = 6.895 kPa, these are about 15.3, 24.1 and 31.0 MPa; the handbook prints 28,132 kPa for 3500 psi, which does not match this conversion.[2] The handbook gives the rated service times of these cylinders as 30, 45 and 60 minutes respectively. Whatever the pressure, Teele (2008) recommends carbon filament or composite cylinders rated for at least 30 minutes, because they weigh significantly less. High-pressure systems also have smaller cylinders, with less bulk and a smaller profile.[2]

The rated service time is a certification value, not a promise of working time. J. Moore (2008), writing about warehouse fires, notes that most SCBA had only a 30- to 45-minute rating and probably last only half that long during strenuous fire fighting.[4] Fire fighters who must walk 300 ft (91.5 m) into such a building may then have only 5 to 7 minutes to fight the fire before they must replenish their air.[4] As an illustration of this estimate, a cylinder rated for 30 minutes would on this basis probably give only about 15 minutes of strenuous work.[4] Snyder (2008) makes the same point for industrial brigades, which therefore need spare air bottles.[17]

Bar chart of rated service time for 15.3, 24.1 and 31.0 MPa cylinders, 30, 45 and 60 minutes, with lighter bars at half the rating
Rated service time of open-circuit SCBA cylinders by working pressure (dark bars) and an illustration of the working time if air lasts about half the rating in strenuous fire fighting (light bars).

Cylinder supply is therefore part of incident logistics. Fire departments could use a dedicated SCBA service unit to service apparatus in the field and recharge depleted cylinders. Such vehicles could carry spare cylinders for exchange, large air cylinders for refilling cylinders in the field, or both large cylinders and a high-pressure air compressor.[19] Tutterow (2008) adds that small departments may not need a separate vehicle, but that every fire department should be able to provide full SCBA cylinders in the field.[19]

The limited air supply also enters fire engineering calculations. The Australian Fire Safety Verification Method handbook states that protective equipment and personal breathing apparatus increase firefighters' resistance to heat and protect them against toxic gases. The capacity of the breathing apparatus should be taken into account when fire brigade intervention is assessed.[20] The maximum safe period inside a building is likely to be limited by the capacity of the tanks.[21] The firefighter tenability criteria in that handbook assume full protective equipment and breathing apparatus; exposure to toxic species is therefore generally not relevant for most buildings.[22]

Putting on the apparatus also takes time. In the International Fire Engineering Guidelines (2005), donning breathing apparatus is part of the initial set-up time at the kerb that the fire brigade intervention model calculates.[23] Johnson and Price (2008) likewise count donning SCBA as part of set-up time. They note that the opportunity to save time during set-up is minimal, even for trained personnel.[24]

SCBA is also used by plant personnel outside fire fighting. On 15 January 1999, an inadvertent carbon dioxide discharge at the Millstone Unit 3 nuclear power plant in the United States let the gas migrate into the control room. When the concentration reached 5,000 ppm, the operators donned SCBA as plant procedures required. The concentration peaked above 17,000 ppm, and the operators wore SCBA for about 6 hours until the room had been purged.[25]

Standards, certification and testing in the United States

In the United States, several layers of rules applied around 2007. OSHA's respiratory protection rule, 29 CFR 1910.134, required employers, including fire departments, to provide suitable respirators and a written respiratory protection programme that includes training.[26] The OSHA fire brigade regulations, 29 CFR 1910.156, required positive-pressure SCBA certified by NIOSH under 42 CFR 84, with a minimum rated service life of 30 minutes.[2] On the NFPA side, NFPA 1500 required fire departments to provide, and fire fighters to use, protective clothing and equipment certified to the applicable NFPA product standard.[14] Its fourth edition, effective 31 January 2002, added a complete section on fire department respiratory protection programmes.[12]

The product standard was NFPA 1981, on open-circuit SCBA for emergency services. As described by Teele (2008), it required NIOSH certification of the design as positive pressure, with a rated service life of at least 30 minutes. The mass could not exceed 35 lb (16 kg).[3] In the airflow test, the SCBA must deliver 100 L/min without the facepiece pressure becoming negative during inhalation or exhalation. This rate exceeds the NIOSH certification requirement of 40 L/min.[3] Thermal cycling evaluates correct function through a series of four tests: cold-cold, hot-hot, cold-hot and hot-cold.[3][27]

The heat and flame test treats the complete apparatus. The SCBA is mounted on a mannequin connected to a breathing machine running at 40 L/min and is conditioned for 15 minutes in an oven at 95 °C.[27] The breathing rate is then raised to 100 L/min, and a flame engulfs the whole unit for 10 seconds at 816 to 1150 °C, with a mean peak temperature of 950 °C. A drop test follows. Throughout, the SCBA must keep working, may show no afterflame beyond 2.2 seconds, must stay mounted, and its lens must not reduce vision below 20/100.[27]

The 2007 edition of NFPA 1981, its sixth edition, required every emergency services SCBA to be certified by NIOSH for CBRN protection as well.[27] NIOSH benchmark tests had shown that chemical warfare agents could cause catastrophic failures of SCBA without such hardening within minutes of exposure. NIOSH reviewed 151 toxic industrial chemicals and chemical warfare agents and chose sarin and sulfur mustard as representative test agents.[27] NFPA 1981 also required a second, independent end-of-service-time indicator, a heads-up display warning of the remaining air supply, and a voice communication system besides the speaking diaphragm.[27]

Other 2007 additions covered cylinder retention, minimum speech scores for the voice diaphragm and the voice system, an independent pressure gauge, and the watertightness and battery life of electronic parts.[27] In the same account, the quality of the breathing air was covered by NFPA 1989, with levels for oxygen, carbon monoxide, carbon dioxide, oil, particulates, hydrocarbons, water and odour. Selection, inspection, cleaning, repair and retirement of SCBA in service were covered by the user standard NFPA 1852.[27][8]

Compliance had to be shown by an accredited, independent third-party certification organisation that tests, labels and lists the product and reviews its production.[28] The cylinders themselves fell under the US Department of Transportation (DOT). Steel cylinders carried the markings DOT3A or DOT3AA, whereas composite cylinders were approved under special "exemptions", most of which set a maximum life of 15 years. DOT required requalification every 3 years for composite and every 5 years for all-metal cylinders, and was considering changes to this schedule at the time of writing.[3]

Use on the fireground

SCBA use is organised around teams. Under OSHA rule 29 CFR 1910.134(g)(4), at least two employees enter an atmosphere immediately dangerous to life and remain in visual or voice contact. At least two more stay outside, and all employees engaged in interior structural fire fighting use SCBA.[29] Citing fire departments under this "two-in/two-out" rule caused confusion and resistance among fire service leaders. The inconsistency with NFPA 1500 was resolved only when a revised NFPA 1500 was passed in May 1997 and OSHA issued its rules in January 1998.[12] The 1997 edition also introduced recommendations for an initial Rapid intervention crew during the early stages of an incident.[30]

Plan view of a burning building with two SCBA wearers inside in contact and two standby members outside the door
The two-in/two-out rule: at least two SCBA wearers enter the atmosphere immediately dangerous to life and stay in visual or voice contact, while at least two more remain outside.

Protection depends on the seal between the facepiece and the face. The positive-pressure feature cannot replace proper fitting and fit testing for each user. It also cannot compensate for anything that passes through the sealing area, such as beards, facial deformities or the temple bows of eyeglasses.[2] OSHA ruled on 15 February 1990 that SCBA use by a person with facial hair at the seal or with eyeglass temple bows or straps violated 29 CFR 1910.134, whatever the fit test result. Persons with severe skin pitting, missing teeth, facial deformities, skull caps or similar conditions were also barred from using SCBA. SCBA manufacturers offered prescription lens frames that fit inside the facepiece without affecting the seal.[2][3]

The breathing apparatus is one element of a larger ensemble. NFPA 1500 required full Structural firefighting protective clothing for structural fire fighting, together with SCBA certified to NFPA 1981 and a personal alert safety system (PASS) certified to NFPA 1982.[31] A PASS contains a sensor that detects movement or its absence and can sound its alarm automatically. According to Teele (2008), in too many fatal incidents many of the fire fighters had been wearing PASS devices but had not turned them on. The 2007 edition of NFPA 1982 therefore required automatic activation, for example by integration with the SCBA so that the PASS starts when the air supply is turned on.[8][32]

At hazardous materials incidents, SCBA was generally the same as for fire fighting, but respiratory equipment is generally not designed to resist chemical contamination. As described by Teele (2008), NFPA 1991 therefore required the SCBA to be worn inside vapour-protective suits. NFPA 1992 allowed it inside or outside liquid splash-protective suits, although wearing it inside was strongly recommended to prevent its failure and reduce decontamination problems.[33] On fire apparatus, NFPA 1901, as described by Tutterow (2008), required SCBA in the cab to be held by a bracket that retains it under a 9 g force in any direction.[34]

The World Trade Center attack of 11 September 2001 showed the value of the equipment. In interviews, emergency responders named radios, flashlights and SCBA as the three items that saved many of their lives.[35] After the towers collapsed, responders used their SCBA to breathe in air thick with dust and smoke, and many shared their air with others nearby.[36][37]

Limitations

SCBA adds weight and heat to the wearer. A normally outfitted New York City fire fighter with a full protective clothing ensemble and SCBA carried about 23 kg, and tools, radios and spare cylinders could add another 23 kg or more.[5] At the World Trade Center in 2001, NIST estimated climbing rates of about 1.4 minutes per floor for responders without extra equipment. The rate rose to about 2.0 minutes per floor for those in protective clothing carrying extra equipment, with an uncertainty of about ±0.5 minutes per floor.[38] During rest periods, many fire fighters removed their SCBA and coats to cool down.[6]

The air supply sets a hard limit. Fire fighters can become trapped or disoriented and lose contact with their crew, a scenario particularly associated with fire fighter deaths from smoke inhalation. Teele (2008) notes that fire fighters face similar dangers, even with SCBA, if they operate beyond the time limits of their air supply.[8] Warning devices help but do not remove the hazard. Teele (2008) stresses that a PASS cannot substitute for an active incident management system, close supervision of crews, communications and a functional personnel accountability system.[32]

Communication is difficult through a facepiece. According to Loflin (2008), the chief communication problem reported by fire fighters and company officers was speaking from inside a fire while wearing full protective equipment, including SCBA.[7] The fire PRA method for US nuclear power plants (NUREG/CR-6850) takes the same view for plant operators. Tasks that require significant activity or communication while wearing SCBA are given little or no credit, because communication under such conditions is believed to be very difficult. Where smoke, heat or toxic gases are severe enough to require SCBA, the likelihood of success is assumed to be extremely low until proven otherwise.[39]

Protection also depends on the condition and availability of the equipment. Respiratory protective equipment is generally not designed to resist chemical contamination.[33] Without a CBRN evaluation, no SCBA components were tested for permeation or penetration by toxic industrial chemicals.[27] Availability was a further problem: in the 2005 needs assessment of the US fire service, an estimated 60 percent of fire departments did not have enough SCBA.[40]

See also

Notes

  1. ↑ 1.0 1.1 1.2 Teele (2008), pp. 12-150–12-151.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 Teele (2008), p. 12-151.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 3.5 Teele (2008), p. 12-152.
  4. ↑ 4.0 4.1 4.2 4.3 J. Moore (2008), p. 20-174.
  5. ↑ 5.0 5.1 Lawson and Vettori (2005), p. 87.
  6. ↑ 6.0 6.1 Lawson and Vettori (2005), p. 90.
  7. ↑ 7.0 7.1 Loflin (2008), p. 12-123.
  8. ↑ 8.0 8.1 8.2 8.3 8.4 8.5 Teele (2008), p. 12-154.
  9. ↑ 9.0 9.1 C. J. Wright (2008a), p. 13-139.
  10. ↑ Iqbal and Salley (2004), p. F-14.
  11. ↑ Iqbal and Salley (2004), p. F-46.
  12. ↑ 12.0 12.1 12.2 Loflin (2008), p. 12-110.
  13. ↑ Gann and Bryner (2008), p. 6-14.
  14. ↑ 14.0 14.1 14.2 Teele (2008), p. 12-144.
  15. ↑ Teele (2008), p. 12-150.
  16. ↑ Klaene and Sanders (2008), p. 13-10.
  17. ↑ 17.0 17.1 Snyder (2008), p. 12-195.
  18. ↑ Iqbal and Salley (2004), p. F-38.
  19. ↑ 19.0 19.1 Tutterow (2008), pp. 12-278–12-279.
  20. ↑ Australian Building Codes Board (2020b), p. 30.
  21. ↑ Australian Building Codes Board (2020b), p. 87.
  22. ↑ Australian Building Codes Board (2020b), p. 111.
  23. ↑ National Research Council of Canada et al. (2005), p. 2.9-3.
  24. ↑ Johnson and Price (2008), p. 12-218.
  25. ↑ Iqbal and Salley (2004), p. B-51.
  26. ↑ Laughlin (2008), p. 12-163.
  27. ↑ 27.0 27.1 27.2 27.3 27.4 27.5 27.6 27.7 27.8 Teele (2008), p. 12-153.
  28. ↑ Teele (2008), p. 12-145.
  29. ↑ Kreckie (2008), p. 13-111.
  30. ↑ Loflin (2008), p. 12-109.
  31. ↑ Teele (2008), p. 12-149.
  32. ↑ 32.0 32.1 Teele (2008), p. 12-155.
  33. ↑ 33.0 33.1 Teele (2008), p. 12-157.
  34. ↑ Tutterow (2008), p. 12-272.
  35. ↑ Lawson and Vettori (2005), p. 105.
  36. ↑ Lawson and Vettori (2005), p. 108.
  37. ↑ National Institute of Standards and Technology (2005), p. 192.
  38. ↑ Lawson and Vettori (2005), p. 91.
  39. ↑ Nowlen et al. (2005b), p. 12-17.
  40. ↑ Jenaway (2008), pp. 12-42–12-43.

References

  • Australian Building Codes Board. (2020b). Handbook: Fire Safety Verification Method (Print version 1.1).
  • Gann, R. G., & Bryner, N. P. (2008). Combustion products and their effects on life safety. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-11–6-34). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Jenaway, W. F. (2008). Needs assessment and hazard analysis. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-41–12-50). National Fire Protection Association.
  • Johnson, R., & Price, M. (2008). GIS for fire station locations and response protocols. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-215–12-231). National Fire Protection Association.
  • Klaene, B. J., & Sanders, R. (2008). Fireground operations. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-3–13-11). National Fire Protection Association.
  • Kreckie, J. (2008). Aircraft rescue and fire fighting (ARFF). In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-99–13-115). National Fire Protection Association.
  • Laughlin, J. W. (2008). Training programs for fire and emergency service personnel. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-161–12-175). National Fire Protection Association.
  • Lawson, J. R., & Vettori, R. L. (2005). The emergency response operations (NIST NCSTAR 1-8). National Institute of Standards and Technology.
  • Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
  • Moore, J. (2008). Storage occupancies. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-157–20-178). National Fire Protection Association.
  • National Institute of Standards and Technology. (2005). Final report on the collapse of the World Trade Center towers (NIST NCSTAR 1).
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Nowlen, S. P., Najafi, B., Wyant, F. J., Forester, J., Kazarians, M., Kolaczkowski, A., Joglar, F., Funk, D., Hannaman, G., & Anoba, R. (2005b). EPRI/NRC-RES fire PRA methodology for nuclear power facilities: Vol. 2. Detailed methodology (NUREG/CR-6850; EPRI 1011989). Electric Power Research Institute; U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research.
  • Snyder, M. (2008). Industrial fire loss prevention. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-177–12-198). National Fire Protection Association.
  • Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
  • Tutterow, R. (2008). Fire department apparatus and equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-267–12-287). National Fire Protection Association.
  • Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-117–13-144). National Fire Protection Association.