Skip to content
From Fire Safety Academy Wiki
Revision as of 18:21, 14 November 2026 by Linda (talk | contribs) (Add SVG figures fse-child-resistant-lighter-v1.svg, fse-child-resistant-lighter-v2.svg, fse-child-resistant-lighter-v3.svg, fse-child-resistant-lighter-v4.svg (list-8 visual plan))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Purpose and principle
  2. 2Children, lighters and fire before 1994
  3. 3The United States requirement of 1994
  4. 4Effect on fires and deaths
  5. 5Place among prevention strategies
  6. 6Limits and remaining risk
  7. 7See also
  8. 8Notes
  9. 9References

A child-resistant lighter is a cigarette lighter designed so that most young children cannot operate it.[1] In the United States, a requirement of the Consumer Product Safety Commission (CPSC) introduced in 1994 made child resistance compulsory for all disposable and some novelty cigarette lighters.[2][3] At least 85 percent of the children aged 2½ to 4½ years who were tested had to be unable to activate such a lighter, and Canada made child-resistant lighters mandatory in 1995.[2] The measure was aimed at children playing with fire, then the leading cause of fire deaths among US preschool children.[4]

Deaths in child-playing fires involving lighters fell immediately after 1994.[3] The CPSC estimated that the standard prevented 130 deaths and 950 injuries in 1998.[2] Hall (2008) regards it as the closest example fire safety is likely to see of a programme with immediate, sustained and substantial improvement.[3] The design does not make a lighter childproof, because some children can still operate it and matches remain a cause of fatal child-set fires.[2][5] Fire safety educators therefore combine the product change with messages telling adults to keep lighters and matches away from children.[6] The trend data and CPSC estimates in this article are from US sources published by 2008.

Purpose and principle

A lighter is an Ignition source, a source of heat that can start a fire. Ignition requires fuel, an oxidiser and a source of heat, and a fire starts when fuel and heat source are brought together, by accident or deliberately.[7] Hall and Cote (2008) describe every hostile fire as needing an initial heat source, an initial fuel source and something to bring them together, which nearly always has a human component.[8] Prevention can act on the heat source, the fuel source or the behaviour that brings them together.[8] In these terms, a child-resistant lighter is a change to the heat source that makes it harder for a young child to produce a flame.[1]

The amount of energy involved gives a sense of scale. In a guide for the US Nuclear Regulatory Commission, Iqbal and Salley (2004) give about 1 kJ of heat energy for a paper match and about 3 kJ for a large wooden safety match. A common butane cigarette lighter contains about 230 kJ, and a 10 cm flame from such a lighter releases energy at about 150 W.[9] As an illustration, a lighter therefore holds roughly 230 times the heat energy of a paper match. Hall (2002b) notes that the fire risk of a heat-source product is measured solely by whether or not ignition occurs.[10]

Bar chart on a log scale: matches contain 1 to 3 kJ, a butane cigarette lighter about 230 kJ
Approximate heat energy contained in matches and in a common butane cigarette lighter (logarithmic scale).

Child resistance is an engineering measure in the sense used by fire prevention planners. Kirtley (2008a) defines the objective of engineering as building safeguards into products and materials that, by their design, eliminate or reduce the risk.[11] He gives fire-resistant wallboard as an example that works without any action by the resident and calls this passive nature a key to its success.[11] Schwartzman (2008) cites the child-resistant lighter as an excellent example of a product engineered to prevent fire use, because it restricts the ability of preschool children to ignite the flame of a disposable lighter.[1]

Children, lighters and fire before 1994

Children playing with fire were the single greatest source of the above-average fire risk of preschool children in the United States.[2] In NFPA's best estimate for 2002, children playing with fire started 13,900 structure fires, which caused 210 civilian deaths, 1,250 civilian injuries and $339 million in direct property damage.[4] Preschool children accounted for 55 percent of child-playing home fire deaths in 1999 to 2002. The children killed were often younger siblings or playmates of the firesetters rather than the firesetters themselves.[2] Preschool children are one of the High-risk populations for fire, and their behaviour with fire is described further under Juvenile firesetting.[12]

Matches were the larger problem at first. In the early 1980s, home structure fires started by children playing with matches far exceeded those started by children playing with lighters, and the death toll with matches was also usually higher.[13] In the mid- to late 1980s some fire safety advocates noticed that the match component was declining rapidly, while the lighter component was not clearly declining at all. This observation led to support for changes that would make lighters more child resistant.[13]

Timeline from 1980 to 2002 of child fires with matches and lighters and the 1994 child-resistant lighter requirement
Timeline of child-playing fires involving matches and lighters in the United States and the child-resistant lighter requirements of 1994 (United States) and 1995 (Canada).

The proposal was disputed. Opponents argued that matches still seemed to be the larger problem in fires and deaths, and possibly also in risk per use. They feared that chasing the lighter problem might shift people to matches, which might be riskier, and so increase fires and deaths.[13] Hall (2008) notes that the ideal response to such conflicting data is more research. Research found that children playing with lighters tended to be younger than children playing with matches, too young to be reached with confidence by educational programmes. Data from the early 1990s also showed lighters passing matches, first in fire deaths and then in fires.[13]

Other work confirms how hard it is to reach very young children with fire safety messages. In 1990 the Learn Not to Burn Foundation tested a video prototype with 50 children in day care. It concluded that public service advertising to young children about matches and lighters would most likely be ineffective, because the 3- and 4-year-olds did not understand the safety message well enough.[14] Mere exposure to pictures of matches and lighters without comprehension could even increase children's interest in playing with them.[14] Hall (2008) lists children playing with fire among the leading causes of fatal fires against which conventional educational techniques are of limited or unproven effectiveness.[15]

The United States requirement of 1994

The Consumer Product Safety Commission introduced the child-resistant lighter requirement in 1994.[3] According to Gamache (2008), it applied to all disposable and some novelty cigarette lighters.[2] Lathrop (2008b) describes the same measure as regulations requiring butane lighters manufactured in the United States to be child resistant from mid-1994.[16] Canada enacted its own legislation in 1995, making child-resistant lighters mandatory there.[2] The handbook chapters do not describe the mechanisms that manufacturers used to achieve child resistance.

The requirement is expressed as a test with children. Gamache (2008) summarises it as follows: at least 85 percent of the children aged 2½ to 4½ years who were tested must not be able to activate the lighter.[2] In words, a lighter passes if the share of tested children who fail to make it work is at least 85 percent. As an algebraic illustration, the criterion can be written with the symbols defined below:

nfailntested≥0.85⇔nopntested≤0.15

Symbol Description Unit
ntested Number of children aged 2½ to 4½ years in the test –
nfail Number of tested children unable to activate the lighter –
nop Number of tested children able to activate the lighter (nop=ntested−nfail) –

As an illustration, if 100 children in the stated age range were tested, a lighter would meet the criterion only if no more than 15 of them could make it produce a flame. The criterion therefore accepts that a minority of young children will succeed. Gamache (2008) reports that, among the children younger than 5 who ignited cigarette lighters in the CPSC study, about one-third were older than 4 years and 3 months.[5] She gives that age as the oldest at which children had to be tested under the CPSC protocol. In other words, about a third of these children were older than any child the protocol required to be tested.[5]

Grid of 100 child icons, at least 85 grey (cannot operate) and at most 15 coloured (can operate)
Illustration of the pass criterion: of 100 tested children aged 2½ to 4½ years, at least 85 must be unable to activate the lighter.

Effect on fires and deaths

The NFPA trend data show a sharp change after 1994. Hall (2008) states that the introduction of the requirement produced an immediate and substantial trend reversal, which was sustained and extended through a number of years.[13] Child-playing fire deaths had risen as a share of all fire deaths and ranked fourth among the causes of home fire deaths in 1993. With the help of the new standard they plunged, and in the years before 2008 they consistently stayed below 10 percent of fire deaths.[13] Ahrens et al. (2008) likewise report that fire-play deaths involving lighters and matches declined sharply after the requirement took effect in 1994.[17] Hall's chart also shows a higher point in 1999, when its definition of “playing” broadened, so the series cannot be compared year by year without that caveat.[3]

The CPSC estimated the effect by comparing the estimated actual losses with the losses expected without the standard. The number of deaths or injuries prevented is the difference between the two. As an algebraic illustration, the subtraction can be written separately for deaths and injuries:

Nprev=Nwithout−Nactual

Symbol Description Unit
Nprev Deaths (or injuries) prevented in a year per year
Nwithout Deaths (or injuries) estimated for the same year in the absence of the standard per year
Nactual Deaths (or injuries) estimated to have occurred per year

For 1998, the CPSC estimated that 70 deaths occurred in residential structure fires caused by children younger than 5 playing with cigarette lighters, against an estimated 200 without the standard. The difference of 130 deaths is the number the CPSC attributes to the standard.[2] For injuries, the estimates were 480 with the standard and 1,430 without it, so 950 injuries were prevented in 1998.[2] As an illustration, these estimates mean that about two-thirds of the expected deaths (130 of 200) and of the expected injuries (950 of 1,430) were avoided in that year. Both terms are estimates, and the value of Nwithout depends on the CPSC's assumptions about what would have happened without the standard, which the handbook does not describe.

Bar chart of 1998 US deaths and injuries from child lighter fires, estimated with and without the standard
CPSC estimates for 1998 of deaths and injuries in US residential structure fires caused by children under 5 playing with cigarette lighters, with and without the child-resistant standard.

The speed of the change reflects the product. Disposable lighters turn over frequently, so the improvement appeared immediately, as would not be expected with a long-lived product such as a mattress.[3] The decline also went beyond lighters. The change in lighter design coincided with a resumption of the dramatic decline in fires caused by children playing with matches.[13] Hall (2008) considers the most obvious explanation to be that educators put more emphasis on educating parents and other caregivers. In his view this reinforced the product change and also produced positive results of its own on match fires.[18]

Other authors in the handbook point in the same direction. Gamache (2008) reports that child-playing fires caused 36 percent of the home fire deaths of children aged 4 or younger in 1994 to 1998, but 26 percent in 1999 to 2002. Part of this decline was real and linked to the child-resistant lighter standards, while part reflected changes in incident coding.[12] Schwartzman (2008) reports that mental health professionals attribute a significant part of the decline in child-set fires since 1994 to fire service programmes together with the lighter requirement.[19] In the chapter on one- and two-family dwellings, Lathrop (2008b) also notes that these child fire deaths dropped sharply after the 1994 requirement.[16]

Place among prevention strategies

The lighter requirement is one of several product changes described in the handbook. Kirtley (2008a) notes that the United States and many other countries changed the design of products ranging from upholstered furniture and mattresses to lighters, space heaters and manufactured homes.[20] Bush (2008) names regulations on child-resistant lighters and research on self-extinguishing cigarettes as two excellent examples of safe product initiatives for homes.[21] Kirtley adds that public education used alone is the least effective of the five mitigation strategies of education, enforcement, engineering, emergency response and economic incentives.[20]

Product changes also have costs and limits. Hall and Cote (2008) list four routes to product redesign: regulation, design to voluntary consensus standards, voluntary industry-wide programmes and redesign in response to consumer demand.[22] They warn that users can undo many design improvements if they have not been educated about fire-safe use. Some product design proposals also have high costs or remove other product features, and any strategy not driven by consumer demand raises concern about freedom of choice.[23]

One comparison of costs is available in the SFPE Handbook. Notarianni (2002) compared the net cost per life-year saved by residential sprinklers with that of other life-saving interventions, including mandating child-resistant cigarette lighters. The comparison drew on a published review of more than 500 interventions, whose results she considers believable within an order of magnitude.[24] In her chart, normalised to the cost of chlorinating drinking water, the bar for child-resistant lighters is lower than those for sprinklers in all three housing types and for the other home interventions shown. Only drinking-water chlorination has a lower bar.[24]

The product change also needs an educational counterpart for full effect. Gamache (2008) stresses that a strategy built on an engineering change still needs education, because some children can operate child-resistant lighters.[5] The NFPA Learn Not to Burn Preschool Program sends letters home that ask parents to keep matches and lighters out of the reach of children, preferably in a locked cabinet. A second letter accompanies the lesson in which children learn to stay away from matches and lighters and to tell a grown-up when they see them.[6] The NFPA Center for High-Risk Outreach also produced an 8-minute video for parents, A Lighter Is Not a Toy. It suggests actions that can prevent serious burns and deaths from fires started by children with access to matches and lighters.[14]

Limits and remaining risk

A child-resistant lighter reduces the chance that a young child can produce a flame, but it does not remove it. Some children can operate these lighters, and the oldest preschool children were partly outside the tested age range.[5] A significant number of the fires that kill young children are started by matches, which the lighter requirement does not cover.[2] Gamache (2008) therefore calls it extremely important to tell adults and caretakers to keep all lighters and matches away from children. Lathrop (2008b) adds that matches and lighters must be kept out of the reach and sight of young children.[2][16]

The effect also levelled off. Even for a programme with immediate, sustained and substantial improvement, Hall (2008) observes that the effects show signs of levelling off at what is still a high death toll.[3] In the national Fire statistics for US homes in 1999 to 2002, matches were the heat source in 4 percent of structure fires and lighters in 3 percent.[25] In this classification, matches and lighters are separate heat sources from smoking materials, the heat source on which the leading-cause category of Smoking-material fires is based.[25][26] In one- and two-family dwellings, playing with a heat source, usually matches or lighters, was the sixth leading cause of fire deaths in 1999 to 2002, with an estimated 180 deaths a year.[27]

Small fires started with a lighter can still be lethal. Purser (2002) describes a fire in which an adult and a four-year-old were in a small bedroom and the adult fell asleep. The child is thought to have ignited a small piece of foam with a cigarette lighter. A family member opened the door a few minutes later and put out the very small fire with a bucket of water.[28] Both the adult and the child died, with blood carboxyhaemoglobin at about half the lethal level. Based on the room dimensions, Purser calculates that the decomposition of about 0.5 kg of material could lower the oxygen concentration to 10 percent and raise carbon monoxide to about 1 percent or more.[28]

The evidence base has its own limits. The CPSC and NFPA values are national estimates for the United States. For 1999 and later the NFPA series on child-playing fires includes all fires attributed to "playing", so it may not be limited to children.[29] Gamache's two descriptions of the tested age range also differ, with 4½ years as the upper age on one page and 4 years and 3 months on another.[2][5] For local evaluation, Hall and Weller (2008) suggest counting residential fires in which the heat of ignition was a match or lighter and the ignition factor was "children playing". They also suggest counting the children injured in such fires.[30]

See also

Notes

  1. ↑ 1.0 1.1 1.2 Schwartzman (2008), p. 5-97.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 Gamache (2008), p. 5-64.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 3.5 3.6 Hall (2008), p. 5-110.
  4. ↑ 4.0 4.1 Gamache (2008), pp. 5-63–5-64.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 Gamache (2008), p. 5-66.
  6. ↑ 6.0 6.1 Gamache (2008), pp. 5-64–5-65.
  7. ↑ National Research Council of Canada et al. (2005), p. 3.3-2.
  8. ↑ 8.0 8.1 Hall and Cote (2008), pp. 3-11–3-12.
  9. ↑ Iqbal and Salley (2004), p. C-1.
  10. ↑ Hall (2002b), p. 5-143.
  11. ↑ 11.0 11.1 Kirtley (2008a), p. 12-310.
  12. ↑ 12.0 12.1 Gamache (2008), p. 5-63.
  13. ↑ 13.0 13.1 13.2 13.3 13.4 13.5 13.6 Hall (2008), p. 5-108.
  14. ↑ 14.0 14.1 14.2 Gamache (2008), p. 5-65.
  15. ↑ Hall (2008), p. 5-112.
  16. ↑ 16.0 16.1 16.2 Lathrop (2008b), p. 20-60.
  17. ↑ Ahrens et al. (2008), p. 3-64.
  18. ↑ Hall (2008), pp. 5-108–5-109.
  19. ↑ Schwartzman (2008), p. 5-88.
  20. ↑ 20.0 20.1 Kirtley (2008a), p. 12-311.
  21. ↑ Bush (2008), p. 20-39.
  22. ↑ Hall and Cote (2008), p. 3-12.
  23. ↑ Hall and Cote (2008), p. 3-13.
  24. ↑ 24.0 24.1 Notarianni (2002), p. 5-62.
  25. ↑ 25.0 25.1 Ahrens et al. (2008), p. 3-72.
  26. ↑ Hall and Cote (2008), p. 3-14.
  27. ↑ Lathrop (2008b), pp. 20-58, 20-60.
  28. ↑ 28.0 28.1 Purser (2002), p. 2-136.
  29. ↑ Hall (2008), pp. 5-108, 5-110.
  30. ↑ Hall and Weller (2008), p. 5-129.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Bush, K. (2008). Apartment buildings. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-37–20-47). National Fire Protection Association.
  • Gamache, S. (2008). Reaching high-risk groups. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-63–5-85). National Fire Protection Association.
  • Hall, J. R., Jr. (2002b). Product fire risk. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 5-143–5-152). National Fire Protection Association; Society of Fire Protection Engineers.
  • Hall, J. R., Jr. (2008). Using data for public education planning and decision making. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-103–5-118). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Hall, J. R., Jr., & Weller, M. W. (2008). Evaluation techniques for fire and life safety education. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-119–5-137). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Kirtley, E. (2008a). Community risk reduction. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-309–12-315). National Fire Protection Association.
  • Lathrop, J. K. (2008b). One- and two-family dwellings. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-55–20-61). National Fire Protection Association.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Notarianni, K. A. (2002). Uncertainty. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 5-40–5-64). National Fire Protection Association; Society of Fire Protection Engineers.
  • Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
  • Schwartzman, P. (2008). Juvenile firesetting. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-87–5-102). National Fire Protection Association.