A solid-fuel heating appliance is a stove, room heater, fireplace stove, fireplace insert, furnace or boiler that heats a building by burning a solid fuel such as wood, wood pellets or coal.[1][2] Most solid-fuel room heaters burn only wood, and every solid-fuel appliance must be connected to a masonry or factory-built chimney.[3][4][5] In the United States the use of wood stoves, furnaces and fireplaces surged from the mid-1970s, and home fires related to heating rose sharply in the early 1980s before declining.[1] Fires in solid-fuel room heaters are due mainly to two underlying conditions: too little clearance to combustible materials and other installation faults, and poor maintenance.[6] A third hazard is creosote, a combustible tar that deposits in the stove, connector and chimney when wood burns with too little air and that can feed an intense chimney fire.[3][7] In the United States, NFPA 211 as summarised in the 2008 handbook sets clearances such as 914 mm (36 in.) around room heaters, floor protection, suitable chimneys and yearly chimney inspection.[2][8]

Types of appliance

A solid-fuel room heater is essentially a fire chamber inside a decorative enclosure, with manual draft controls or a thermostatic control and a chimney connector.[6][3] Most such heaters burn only wood, which lies on a bed of firebrick, ashes or sand; coal needs a grate so that air can reach the fuel from below.[3] Wood and coal stoves, like fireplace inserts, are classed as radiant room heaters, because they are not built as circulating heaters with an air jacket.[6] Pellet appliances, introduced in the mid- to late 1980s, burn pellets of milled wood waste about 6 mm in diameter and 12–25 mm long. The pellets are metered from a hopper to a burn pot, which brings a degree of automatic operation to residential solid fuel.[1]

Fireplaces are open fire chambers without control of the air supply. A fireplace stove is a free-standing factory-built unit with an open front, and with doors it can also operate as a stove with controlled combustion air.[8] Glass doors on a masonry fireplace, or a closed-front fireplace insert, change its combustion characteristics to those of a heater.[8] An insert must be connected directly to the masonry flue through the damper and smoke chamber, and appliances may not be fitted into a factory-built fireplace unless listed for it.[8] A worked example in the SFPE Handbook takes a glass fire screen of 0.71 m by 1.02 m at 232 °C in a room at 23 °C. It gives about 1,060 W to the room by natural convection alone, and radiant heat transfer would be greater still.[9]

Central solid-fuel appliances include furnaces and boilers fired by hand or by mechanical stokers handling 4.5–540 kg (10–1,200 lb) of coal per hour.[10] Solid-fuel add-on furnaces connect to the ductwork of an existing furnace and supply heat as a supplement, usually under their own thermostat.[11] Some older solid-fuel boilers need 15–20 m (50–70 ft) of chimney height to produce the draft for their fuel bed.[12]

Combustion of wood and coal

Wood burns in three stages. Moisture is driven off first; then destructive distillation releases combustible gases and leaves charcoal; finally the gases burn above the wood and the charcoal glows as a hot bed of coals.[1] The underlying process is pyrolysis, the decomposition of a material by heat into gases, which needs no oxygen, although the combustion of those gases does.[13] Depending on how well the gases mix with air and on the energy available, they burn at once, later or not at all.[13] The burning rate of wood accelerates until it is limited by the rate at which air reaches the fuel.[1]

Coal burns in a fuel bed. Primary air entering through the grate forms carbon dioxide in the lower oxidation zone, and part of it is reduced to carbon monoxide higher up. Secondary air over the bed burns some of this carbon monoxide.[10] Bituminous coal gives off considerable smoke and soot if it is fired improperly.[10] In hand firing of highly volatile coal, a bed of glowing fuel must remain to ignite the gases driven from a fresh charge, otherwise the gas can accumulate and explode.[10] Because the fire in a hand-fired appliance is continuous, overheating is hard to control unless the fire is attended.[10]

When wood burns with restricted air, its tars and other hydrocarbons are not fully consumed and deposit as creosote.[3] Airtight stoves run with the draft controls closed or with large fuel loads can build up a significant layer in a short time.[14] The species and moisture content of the wood are not the main factors, but the habits of stove operation are. A stove sized to the heating need avoids long, air-limited, low-temperature burning.[14]

Fire hazards

A solid-fuel appliance is an ignition source whose fire, once lit, burns continuously.[10] Fires in solid-fuel room heaters have two main underlying causes: inadequate clearance to combustibles or other installation faults, and improper or inadequate maintenance.[6] Some wood stoves need frequent charging and careful draft regulation to prevent overheating, and weather can change the chimney draft.[6] Overfiring is a severe and immediate hazard as soon as the unit or its connector glows even a very dull red, and the remedy is to close the doors and air dampers.[3] Ashes containing live coals are a hazard when they are collected in combustible containers or set on a combustible floor.[3] Problems with the single-wall connector include violations of its required 457 mm (18 in.) clearance and unprotected passage through a combustible wall.[3]

Long exposure lowers the temperature at which wood ignites. For short-term heating, a literature review cited in the handbook recommends an ignition temperature of 250 °C (482 °F) for wood. Yet a steam pipe at 77 °C (170 °F) ignited wooden members in contact with it after many years.[15] Wood changes colour from about 93 °C (199 °F) upwards and is charred at 300 °C (572 °F) whatever the duration.[15] For this reason the handbook sets a limit of 82 °C (180 °F) on exposed combustibles under any conditions of operation.[2]

A masonry covering fixed directly to combustible material without an air space can even increase the heat transfer to it, so solid brick, concrete or plaster may not protect.[16][17] For masonry in fire near stoves this means that the mass of the masonry delays the heating of hidden combustibles but does not prevent it.[17] The handbook illustrates fires beneath stoves standing on concrete, brick and plaster bases that a layperson might consider safe.[16]

Add-on furnaces have their own hazards. Their large combustion chambers hold much wood, and when the heat demand is low the thermostat keeps the fire low and smouldering, which produces much creosote.[11] In a series connection, often used with unlisted or homemade add-ons, the unit relies on the blower of the existing furnace. In a power failure it keeps producing heat while the blower stops, and very hot air backs up into return ducts that may be combustible.[11] NFPA 211 prohibits venting a solid-fuel appliance and an appliance burning other fuels through the same chimney flue.[11] In repair garages, where heat-producing appliances have ignited flammable vapours, solid-fuel burning devices are typically not an approved type of appliance.[18]

Open fireplaces transfer heat mainly by radiation, so furnishings or walls too close to the fire can ignite. Sparks or rolling logs can ignite carpets, and prolonged overfiring can conduct heat through the hearth to structural materials.[19] Burning a dried Christmas tree or wrappings, or using flammable liquids to start a fire, can ignite creosote or drive flames out of the opening.[19] Tight, depressurised houses can draw flue gases back down the chimney, and incomplete combustion can then bring carbon monoxide into the living space.[17] In the United States, non-fire carbon monoxide deaths from solid-fuelled devices such as coal furnaces, wood stoves and fireplaces numbered between 0 and 10 a year in 1993–2002.[20]

Creosote and chimney fires

In chimney systems, creosote means the tarry brown or hard black deposits produced by burning wood. These deposits ignite when the temperature is high enough and burn at 650–1,100 °C (1,200–2,000 °F).[7] The ignition of combustible soot or creosote deposits is one of eight causes of fire in chimneys serving oil, wood or coal appliances; others are operator error, control failure, improper installation and defective construction.[21] In masonry chimneys an intense chimney fire can crack tiles and brickwork and overheat the outer surface, and sparks carried up the flue can drop onto the roof.[7] Factory-built chimneys are tested with repeated flue gas temperatures of up to 1,149 °C (2,100 °F) for up to 30 minutes, yet chimney fires can exceed these conditions.[7]

The energy in a creosote layer is considerable. The handbook states that a layer 1.6 mm (1/16 in.) thick in an 8 in. (200 mm) chimney 4.6 m (15 ft) high contains up to 128 MJ (122,000 Btu). If it burns in 15 minutes, the temperature could reach about 930 °C (1,700 °F) at a heat release rate of up to about 140 kW.[19] The average heat release rate follows from the stored energy and the burning time:

Q˙=Et

Worked example: with E = 128 MJ and t = 15 × 60 = 900 s, Q˙ = 128,000 kJ / 900 s ≈ 142 kW, in line with the handbook's 140 kW. A common rule of thumb calls for cleaning at a build-up of 6.4 mm (1/4 in.), four times the layer in the example.[8] If the stored energy scaled with thickness, such a layer would hold about 515 MJ and burn at about 570 kW over the same 15 minutes. These values are small next to a burning sofa of about 2.5 MW, but they are released inside a narrow flue next to the building structure.[22] The rule of thumb suits soft or crusty deposits; a smooth, hard tar glaze holds more energy and calls for immediate cleaning at any thickness.[8]

The best way to control a chimney fire in a stove with doors and dampers is to close them and cut the air supply.[7] Because the fire can spread to the structure, the handbook advises that occupants prepare to leave and that the fire department be called.[8] After a fire both masonry and factory-built chimneys need a thorough inspection, preferably with closed-circuit video, because clay liners crack from thermal shock and metal liners can buckle.[7] NFPA 211 requires every chimney to be inspected at least once a year, whatever the fuel of the connected appliances.[8] Regular inspection and cleaning matter most for solid-fuelled units, as safe fuelling does for liquid-fuelled ones.[23]

Clearances and floor protection

Clearances to combustibles for listed solid-fuel appliances in large rooms come from NFPA 211. Room heaters, fireplace stoves and combination units need 914 mm (36 in.) above and on every side. Gravity and forced-air furnaces need 457 mm (18 in.) above, behind and at the sides with 1,219 mm (48 in.) in front, and boilers 152 mm (6 in.) with 1,219 mm in front.[2] Fuel must be stored at least 914 mm (36 in.) from any side of the appliance.[2] Laboratory tests for listing establish the required clearances, which for large heaters can exceed 0.9 m (36 in.).[3] Single-wall metal pipe may not serve as the chimney of a solid-fuel appliance.[5]

A clearance can be reduced by a shield of sheet metal, insulation board or masonry.[24] Systems with a ventilated air space need at least 25 mm (1 in.) between the shield and the combustible wall.[25] The shields spread the heat, and the air currents behind them keep the combustible surface below a dangerous temperature even at the smaller clearance.[24] The handbook gives the minimum allowable clearance with protection as a percentage reduction of the unprotected clearance:[25]

Cpr=Cun(1−R100)

Symbol Description Unit
Cpr minimum allowable clearance with protection mm
Cun required clearance with no protection mm
R maximum allowable reduction for the protection system %
Q˙ average heat release rate of a creosote fire kW
E energy stored in the deposit kJ
t burning time s

Worked example: a fireplace stove needs 914 mm (36 in.) to an unprotected wall. Sheet metal of 0.61 mm (24 gauge) on spacers with a ventilated air space allows a reduction of 66 % as a wall protector and 50 % as a ceiling protector.[25] The wall clearance becomes 914 × (1 − 0.66) ≈ 311 mm, which the table gives as 12 in. (305 mm). As a ceiling protector the same system gives 457 mm. A 90 mm (3½ in.) masonry wall without an air space allows only 33 %, so the clearance stays at about 610 mm.[25]

The same rule applies to chimney connectors. For a single-wall connector with a required 457 mm, a 66 % reduction leaves about 155 mm, and the connector table lists 152 mm (6 in.).[26][4] The reductions never apply in front of the loading or ash removal door.[25]

Floors need protection too. Stoves and room heaters with less than 50 mm (2 in.) of ventilated space beneath the fire chamber must not stand on combustible floors.[27] With 50–150 mm (2–6 in.) of space, a combustible floor needs 100 mm (4 in.) of hollow masonry covered with sheet metal. With more than 150 mm, masonry units at least 51 mm (2 in.) thick under sheet metal suffice, in both cases extending 460 mm (18 in.) on all sides.[27]

Masonry fireplaces with an opening under 0.56 m² (6 ft²) need hearth extensions of at least 406 mm (16 in.) in front and 203 mm (8 in.) at the sides.[8] Larger openings need 508 mm and 305 mm.[8] For large, high fireplaces the 508 mm hearth width may be grossly inadequate.[19]

In New Zealand the Building Code expresses the same aim as a temperature. Clause C2.2 limits the surface temperature of combustible building materials close to fixed appliances using controlled combustion to 90 °C at the design operating level.[28] The 2013 commentary explains that this value is consistent with the maximum rise of 65 °C above ambient used in Appendix B of AS/NZS 2918. It names AS/NZS 2918 and AS/NZS 3869 as appropriate standards for constructing and installing these appliances.[29] The commentary lists them as AS/NZS 2918:2001 and AS/NZS 3869:1999, both on domestic solid fuel burning appliances, the second covering design and construction.[30]

Fire statistics

Fires involving coal and wood stoves in United States homes dropped sharply after the early 1980s.[6] Estimates of home fires involving wood or coal stoves peaked in 1983 and fell by more than three-quarters by 1998.[3] The handbook attributes much of the improvement to more care in the correct installation and operation of the appliances, and to less use of installed appliances.[1][6] In 1995–1999 fixed solid-fuel heaters such as wood stoves caused about 60 fire deaths, a rate of 3.32–3.91 deaths per million households.[31] That rate was lower than for portable liquid-fuelled, portable electric and fixed gas heaters, but higher than for fixed electric heating.[31]

In home structure fires in 1999–2002, a fireplace or chimney was the equipment involved in 3 % of fires, and confined chimney fires made up another 3 %.[32] The confined chimney or flue fires numbered 10,600 a year and caused no civilian deaths.[33] They form part of the wider heating equipment fire category. The data have limits: older versions of the United States fire reporting system did not separate wood from coal, and chimney fires had to be matched to wood stoves or fireplaces by special estimates.[34] Fire load data reflect the fuel as well. In Swiss surveys of 1967–1969, a heating equipment room with wood or coal firing had a fire load density of 300 MJ/m², against 500 MJ/m² for homes.[35][36]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 Gore Willse (2008a), p. 10-11.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 Gore Willse (2008a), p. 10-31.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 Gore Willse (2008a), p. 10-24.
  4. ↑ 4.0 4.1 Gore Willse (2008a), p. 10-39.
  5. ↑ 5.0 5.1 Gore Willse (2008a), p. 10-43.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 6.5 6.6 Gore Willse (2008a), p. 10-23.
  7. ↑ 7.0 7.1 7.2 7.3 7.4 7.5 Gore Willse (2008a), p. 10-52.
  8. ↑ 8.00 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 Gore Willse (2008a), p. 10-53.
  9. ↑ Atreya (2002), p. 1-70.
  10. ↑ 10.0 10.1 10.2 10.3 10.4 10.5 Gore Willse (2008a), p. 10-10.
  11. ↑ 11.0 11.1 11.2 11.3 Gore Willse (2008a), p. 10-27.
  12. ↑ Gore Willse (2008a), p. 10-49.
  13. ↑ 13.0 13.1 Van Rossum (2027), §3.1.
  14. ↑ 14.0 14.1 Gore Willse (2008a), p. 10-25.
  15. ↑ 15.0 15.1 Cholin (2008c), p. 6-68.
  16. ↑ 16.0 16.1 Gore Willse (2008a), p. 10-34.
  17. ↑ 17.0 17.1 17.2 Gore Willse (2008a), p. 10-35.
  18. ↑ Rivkin (2008a), p. 21-33.
  19. ↑ 19.0 19.1 19.2 19.3 Gore Willse (2008a), p. 10-55.
  20. ↑ Hall and Twomey (2008), p. 1-24.
  21. ↑ Gore Willse (2008a), p. 10-50.
  22. ↑ Van Rossum (2027), §4.5.
  23. ↑ Lathrop (2008b), p. 20-58.
  24. ↑ 24.0 24.1 Gore Willse (2008a), p. 10-33.
  25. ↑ 25.0 25.1 25.2 25.3 25.4 Gore Willse (2008a), p. 10-32.
  26. ↑ Gore Willse (2008a), p. 10-38.
  27. ↑ 27.0 27.1 Gore Willse (2008a), p. 10-37.
  28. ↑ Ministry of Business, Innovation and Employment (2013), p. 14.
  29. ↑ Ministry of Business, Innovation and Employment (2013), p. 15.
  30. ↑ Ministry of Business, Innovation and Employment (2013), p. 5.
  31. ↑ 31.0 31.1 Hall (2008), p. 5-106.
  32. ↑ Ahrens et al. (2008), p. 3-72.
  33. ↑ Hall and Cote (2008), p. 3-15.
  34. ↑ Hall and Ahrens (2002), p. 5-73.
  35. ↑ National Research Council of Canada et al. (2005), p. 3.4-2.
  36. ↑ National Research Council of Canada et al. (2005), p. 3.4-5.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Atreya, A. (2002). Convection heat transfer. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 1-44–1-72). National Fire Protection Association; Society of Fire Protection Engineers.
  • Cholin, J. M. (2008c). Wood and wood-based products. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-61–6-74). National Fire Protection Association.
  • Gore Willse, P. J. (2008a). Heating systems and appliances. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 10-9–10-56). National Fire Protection Association.
  • Hall, J. R., Jr. (2008). Using data for public education planning and decision making. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-103–5-118). National Fire Protection Association.
  • Hall, J. R., Jr., & Ahrens, M. J. (2002). Data for engineering analysis. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 5-65–5-78). National Fire Protection Association; Society of Fire Protection Engineers.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Hall, J. R., Jr., & Twomey, E. R. (2008). Challenges to safety in the built environment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 1-3–1-29). National Fire Protection Association.
  • Lathrop, J. K. (2008b). One- and two-family dwellings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-55–20-61). National Fire Protection Association.
  • Ministry of Business, Innovation and Employment. (2013). Commentary for Building Code clauses C1–C6 and Verification Method C/VM2.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Rivkin, C. H. (2008a). Automotive and marine service station operations. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-29–21-40). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.