== Summary ==
== Summary ==
Theoretical buoyancy pressure in a vent against mean vent gas temperature, from Δp = g h (ρa − ρg) with ρ = 353/T and outdoor air at 20 °C; the 38 °C Category IV comparison is hypothetical because those appliances require mechanical venting. Based on Van Rossum (2027), §3.2, and Gore Willse (2008a), pp. 10-45 and 10-49.
Theoretical buoyancy pressure in a vent against mean vent gas temperature, from Δp = g h (ρa − ρg) with ρ = 353/T and outdoor air at 20 °C; the 38 °C Category IV comparison is hypothetical because those appliances require mechanical venting.


Original illustration for [[Gas appliance venting]].
Original illustration for [[Gas appliance venting]].

Latest revision as of 09:07, 13 November 2026

Summary

Theoretical buoyancy pressure in a vent against mean vent gas temperature, from Δp = g h (ρa − ρg) with ρ = 353/T and outdoor air at 20 °C; the 38 °C Category IV comparison is hypothetical because those appliances require mechanical venting.

Original illustration for Gas appliance venting.

  • Alt text: Line chart of natural draft in pascals against mean vent gas temperature for vent heights of 1.5 and 3.7 metres, staying below about 17 Pa

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.