Summary
Spalling of a heated concrete lining (left) and the effect of polypropylene fibres that melt at about 170 °C and let steam escape (right). Based on Kodur and Harmathy (2002), pp. 1-163 and 1-171.
Original vector illustration for Tunnel fire, level 2 Intermediate.
- Source basis: Kodur and Harmathy (2002), p. 1-163 (definition and cause of spalling, consequences) and p. 1-171 (polypropylene fibres melt at about 170 °C, channels, 0.1–0.25 % by volume); Fleischmann and Buchanan (2002), p. 4-255 (risk factors, exposed reinforcing steel)
- Alt text: Two cross-sections of a heated concrete lining: left, pieces break off and expose the reinforcement; right, melted fibres leave channels for steam.