Summary

The factor wf of the Eurocode time equivalence formula against the ratio of window area to floor area, without roof openings, for room heights of 3 m and 5 m. Based on Ministry of Business, Innovation and Employment (2025b), p. 24.

Original illustration for Time equivalence, level 4 Expert.

  • Source basis: Ministry of Business, Innovation and Employment (2025b), p. 24 (Equation 2.2 and the range 0.025 to 0.25); Australian Building Codes Board (2020a), Data Sheet B3, p. 37 (Equation 3.4)
  • Alt text: Line chart: w_f falls from about 2.9 to 0.8 as the window-to-floor ratio rises from 0.025 to 0.25; the 5 m room lies below the 3 m room.