Summary

The illustrative visibility history reaches its criterion before the thermal dose history. Based on Australian Building Codes Board (2020), p. 110, and Ministry of Business, Innovation and Employment (2025), p. 17.

Original illustration for Tenability criteria, level 3 Advanced.

  • Source basis: Australian Building Codes Board (2020), p. 110, criteria only; Ministry of Business, Innovation and Employment (2025), p. 17, first-criterion principle. Histories constructed for illustration.
  • Alt text: For invented histories, visibility crosses ten metres at 165 seconds and thermal dose crosses 0.3 at approximately 212 seconds.
  • Accuracy notes: Do not present the 15 second difference as an acceptable safety margin or these two checks as a complete fire assessment. Retain the unrounded thermal crossing coordinate of 212.5 s, but label the available time conservatively as approximately 212 s.