Contents
Fse-tenability-criteria-v1.svg (SVG file, nominally 900 × 600 pixels, file size: 9 KB)
Summary
Tenability assessment retains separate hazard criteria before identifying the earliest limiting condition. Based on Purser (2002), pp. 2-85–2-91, and Ministry of Business, Innovation and Employment (2025), pp. 17–18.
Original illustration for Tenability criteria, level 3 Advanced.
- Source basis: Purser (2002), pp. 2-85–2-91; Ministry of Business, Innovation and Employment (2025), pp. 17–18.
- Alt text: Four distinct hazard checks feed a comparison of their limiting times under stated occupant and location assumptions.
- Accuracy notes: Do not add different indices or present a criterion as an exact physiological response for every occupant.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 16:35, 2 November 2026 | 900 × 600 (9 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: