Contents
Fse-structural-fire-engineering-v3.svg (SVG file, nominally 900 × 600 pixels, file size: 7 KB)
Summary
Thermal expansion of heated floor beams pushed a girder off its seat at a column in World Trade Center 7. Based on National Institute of Standards and Technology (2008), pp. 21–22.
Original vector illustration for Structural fire engineering, level 2 Intermediate.
- Source basis: National Institute of Standards and Technology (2008), p. 21 (expansion at or below about 400 °C; forces when expansion is resisted) and p. 22 (girder between Columns 79 and 44 pushed west, walked off its support at Column 79)
- Alt text: Plan sketch of a floor: heated beams expand and push a girder sideways until it slides off its seat at a column.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:15, 2 November 2026 | 900 × 600 (7 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |