Summary

Time to BLEVE in fire tests on LP-gas tank cars, compared with the design target of thermal protection (tank metal below 427 °C for 100 min in a pool fire, 30 min in a torch fire).

Original illustration for Rail tank car.

  • Alt text: Horizontal bar chart: BLEVE after 25 minutes uninsulated and 93 minutes insulated, with thermal protection target of 100 minutes in a pool fire