Summary

Alternative escape routes in C/VM2: they diverge at 90° or more until 8 m apart, or 20 m apart when more than 250 people use only two routes. Based on Ministry of Business, Innovation and Employment (2025b), p. 37.

Original vector illustration for Protected escape route, level 2 Intermediate.

  • Source basis: Ministry of Business, Innovation and Employment (2025b), p. 37 (Paragraph 4.1.1.5)
  • Alt text: Plan of a room with two exits: routes leave a common point at an angle of at least 90 degrees and are 8 m or 20 m apart at the exits.