Contents
Fse-equivalency-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 10 KB)
Summary
An improved margin in one scenario does not satisfy a separate failing comparison in another. Based on Australian Building Codes Board et al. (2005), p. 1.2-22, with hypothetical values.
Original illustration for Equivalency, level 3 Advanced.
- Source basis: Australian Building Codes Board et al. (2005), p. 1.2-22; calculations/equivalency.py.
- Alt text: Bars compare the reference and trial margins in two scenarios, showing a pass in A and a failure in B.
- Accuracy notes: Use one shared scale. Do not sum, average or probability-weight the margins.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:11, 2 November 2026 | 900 × 600 (10 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: