Contents
Fse-effective-heat-of-combustion-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 9 KB)
Summary
Approximate values at two stages of one cedar test; they are not universal timber properties. Based on Babrauskas (2002), pp. 3-1–3-2.
Original illustration for Effective heat of combustion, level 3 Advanced.
- Source basis: Babrauskas (2002), chapter 3-1, pp. 3-1–3-2, Figure 3-1.1; redraw, do not copy. The bars represent approximate stage values stated in the text, not digitised observations.
- Alt text: Two bars show approximately 12 MJ/kg early in the cedar test and 30 MJ/kg during final charring.
- Accuracy notes: Do not imply constant mass loss, exact measurement times, error bars or a full time history. Preserve 17 mm and 65 kW/m² as the test conditions.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 16:10, 2 November 2026 | 900 × 600 (9 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity | |
| 07:25, 2 November 2026 | 900 × 600 (6 KB) | Emma (talk | contribs) | Level 3 visual plan: fse-effective-heat-of-combustion-v2.svg |
You cannot overwrite this file.