Skip to content
From Fire Safety Academy Wiki
Contents
  1. 1Summary
  2. 2Licensing

Fse-critical-water-application-rate-v5.svg (SVG file, nominally 900 × 600 pixels, file size: 13 KB)

Summary

Heat release rate after sprinkler activation for a 500 kW light hazard fire in the NIST suppression model, for two spray densities. Based on Fleming (2002), p. 4-87.

Original illustration for Critical water application rate, level 4 Expert.

  • Source basis: Fleming (2002), p. 4-86 (origin of the NIST model in wood crib tests) and p. 4-87 (equation, validity limits, 500 kW example)
  • Alt text: Line chart: after sprinkler activation a 500 kW fire falls to 432 kW in 60 s at 0.07 mm/s and to 172 kW at 0.205 mm/s.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current17:28, 2 November 2026Thumbnail for version as of 17:28, 2 November 2026900 × 600 (13 KB)Jan (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata