Summary
Alternative treatments of the heated uncharred region must use compatible design assumptions. Based on White (2002), pp. 4-265–4-267.
Original illustration for Charring rate, level 3 Advanced.
- Source basis: White (2002), pp. 4-265–4-267.
- Alt text: Two approaches to account for strength loss in wood behind the char boundary.
- Accuracy notes: Do not apply both approaches cumulatively or label the additional effective layer as measured char.