Contents
Fse-charring-rate-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 7 KB)
Summary
Three-sided geometric section loss for the illustrative constant-rate calculation. Based on White (2002), pp. 4-260, 4-266 and 4-268.
Original illustration for Charring rate, level 3 Advanced.
- Source basis: White (2002), pp. 4-260, 4-266 and 4-268; derived arithmetic in calculations/charring-rate.py.
- Alt text: Original and simplified residual beam sections after 36 mm char depth on three faces.
- Accuracy notes: No char removed from top. Do not label the shape a validated 60-minute design. Actual rounded corners are omitted explicitly.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 16:36, 2 November 2026 | 900 × 600 (7 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |