Tunnel ventilation moves air through a tunnel or through ducts serving it. In a road tunnel, normal ventilation dilutes vehicle pollutants. During a tunnel fire, emergency ventilation aims to keep smoke and heat away from people moving towards an exit and to support access for rescue. A system that supplies enough fresh air for traffic can still move smoke in an unsuitable direction during a fire.[1]

The two main approaches are to carry smoke along the tunnel or to extract it near the fire. Their suitability depends partly on where vehicles have stopped. Directing smoke along an empty downstream stretch has different consequences from directing it over a queue. The location of exits and the conditions on both sides of the fire therefore belong in the same assessment as fan performance.[1][2][3]

Two tunnel sections show smoke moved along the bore by longitudinal flow or removed through a local overhead opening.
Longitudinal ventilation directs smoke along the roadway. Local extraction draws gases towards an exhaust opening. Based on Bendelius (2008), §21.11, pp. 21-196–21-198.

Longitudinal flow and backlayering

Longitudinal ventilation moves air along the roadway. In jet fan ventilation, fans inside the tunnel transfer momentum to this larger body of air. The supply side of the fire is called upstream. Downstream is the direction in which the bulk airflow carries smoke. These terms refer to airflow, which may differ from the normal direction of traffic.[1][4]

Hot gases can travel along the ceiling against the incoming air. This is called backlayering. In a steady design condition, critical velocity is the minimum longitudinal approach velocity that prevents this upstream movement. It depends on the selected fire, tunnel cross-section and gradient. Smoke continues to travel downstream even when the upstream backlayer has been prevented.[1][4]

Incoming air flows right at low level. A tongue of ceiling smoke runs left from the fire while other smoke moves downstream.
Backlayering occurs when buoyant smoke runs upstream along the ceiling against the approach airflow. Based on Bendelius (2008), §21.11, pp. 21-204–21-205.

Extraction near the fire

A transverse system can supply or remove air through ducts and openings distributed along the tunnel. Concentrating extraction near the incident can limit the distance smoke travels along the roadway. Air from both sides may then move towards the extraction zone. Its performance depends on the fire’s position relative to the available openings.[1][2]

Traffic can be trapped on both sides in a two-way tunnel. In a one-way tunnel, congestion can also leave people downstream of a fire. The route taken by smoke on its way to an exhaust opening matters for those occupants, even if the system ultimately removes that smoke.[2][3]

Vehicles are stopped on both sides of a fire. Air approaches a ceiling extraction point from both directions.
In a two-way or congested tunnel, the route from the fire to an exhaust opening matters for people on either side. Based on Bendelius (2008), §21.11, pp. 21-197–21-198, 21-210.

A design fire and an escape route

A design fire describes the fire used for an engineering assessment. Its heat release rate is the energy released per unit time and helps determine how strongly buoyancy drives smoke. That input differs from a prescribed temperature–time exposure such as the RWS fire curve, named for the Dutch Rijkswaterstaat. The curve concerns the exposure of the structure. The choice of a smoke-control mode also depends on traffic direction, portal conditions and escape routes.[5][6][4][3]

Full-scale tests provide a check on predicted movement. The EUREKA and Runehamar programmes in Norway are among the international tunnel experiments reviewed by Bendelius. A calculation can then compare the predicted smoke distribution with the time people need to reach cross-passages or exits. Maintaining smoke control upstream addresses only one part of that comparison.[7][3]


Reading a smoke velocity from a test

In two naturally ventilated Memorial Tunnel tests on a 3.2% gradient, the measured peak smoke velocities were 6.1 m/s and 8.1 m/s. The nominal fire sizes were 20 MW and 50 MW respectively. Smoke filled the roadway in five minutes in the first test and three minutes in the second. These velocities describe the moving smoke. A critical velocity describes the incoming ventilation air needed to prevent backlayering.[8][4]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 Bendelius (2008), §21.11, pp. 21-196–21-198.
  2. ↑ 2.0 2.1 2.2 Bendelius (2008), §21.11, pp. 21-197–21-198, 21-210.
  3. ↑ 3.0 3.1 3.2 3.3 Bendelius (2008), §21.11, pp. 21-205–21-207.
  4. ↑ 4.0 4.1 4.2 4.3 Bendelius (2008), §21.11, pp. 21-204–21-205.
  5. ↑ Van Rossum (2027), §4.5.
  6. ↑ Van Rossum (2027), §8.6.
  7. ↑ Bendelius (2008), §21.11, pp. 21-207–21-210.
  8. ↑ Bendelius (2008), §21.11, p. 21-209, Table 21.11.14, reporting the Memorial Tunnel fire ventilation tests.

References

  • Bendelius, A. G. (2008). Road tunnels and bridges. In A. E. Cote (Ed.), Fire protection handbook (20th ed.). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.