Skip to content
From Fire Safety Academy Wiki
Revision as of 18:48, 14 November 2026 by Linda (talk | contribs) (Add SVG figures fse-standards-of-cover-v1.svg, fse-standards-of-cover-v2.svg, fse-standards-of-cover-v3.svg, fse-standards-of-cover-v4.svg (list-8 visual plan))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Definition and names
  2. 2Origin and purpose
  3. 3The process step by step
  4. 4Writing the cover statement
  5. 5From cover to staffing
  6. 6Measuring compliance
  7. 7Relation to other approaches and limits
  8. 8See also
  9. 9Notes
  10. 10References

Standards of cover, also called the standard of response cover or standards of response coverage, are a fire department's written policies on where, how quickly and with what force it responds to emergencies. The Commission on Fire Accreditation International (CFAI) gives a formal definition. It describes "those adopted, written policies and procedures that determine the distribution, concentration, and reliability of fixed and mobile response forces".[1] These forces cover fire fighting, emergency medical service, hazardous materials and other technical response.[1]

A standards of cover document starts from a community risk assessment and ends with statements such as "In 90 percent of all incidents, the first-due unit shall arrive within 4 minutes' travel".[2] In between, the department studies its existing deployment, the spread of its stations, its ability to assemble a full response force and its record in meeting its targets.[3] As described in 2008, developing such a document was an essential component of CFAI accreditation.[4] Johnson and Price (2008) present the process as a guideline for deployment next to national standards such as NFPA 1710.[5] The descriptions below follow the 2008 NFPA handbook and the CFAI documents of 2003 that it cites.

Definition and names

The handbook uses several names for the same concept. Jenaway (2008) writes "standard of response cover" and abbreviates the process as SORC.[3] Johnson and Price (2008) and Denlinger (2008) write "standards of response coverage", and Krakeel (2008) calls the result a "Standard of Cover" document.[5][6][4] In the United Kingdom, earlier "standards of coverage documents" were replaced in 2004 by The National Plan.[7] The two CFAI sources cited are Standard of Response Cover (2003) and the fourth edition of Creating and Evaluating Standards of Response Coverage for Fire Departments (2003).[8][9]

The definition contains three key words. Distribution is the geographic spread of first-due resources, so that routine emergencies receive a quick initial response. Concentration is the spacing of several resources close enough together to assemble an effective response force within the adopted time.[3] Reliability is the ability to meet the targets even when some units are already committed to other calls.[3]

Jenaway (2008) places the standard of response cover among several needs-assessment tools. Once the hazards are evaluated, the resources to manage them can be defined, and the expected service delivery capability, the standard of response cover, can be established.[1] In his terms, a hazard is the level of harm associated with exposure to a fire, and risk is the expected loss from a fire of a given severity.[10]

Origin and purpose

The CFAI was initiated by the International Association of Fire Chiefs and the International City-County Management Association. It accredits fire departments that complete a self-assessment and peer review against its criteria, and in 2008 it resided within the Center for Public Safety Excellence.[4] Krakeel (2008) gives 1995 for its formation on one page and 1996 for its establishment on another, and describes a voluntary programme of 10 categories with performance indicators.[11] The Tempe, Arizona, Fire Department was the first agency to be accredited.[4]

Granito (2008) describes the accreditation process as a standardised method by which departments assess and rate themselves, with the help of a visiting team.[12] Jenaway (2008) adds that the self-assessment is extremely helpful in determining needs and analysing risks even when a department does not seek formal accreditation. Within it, the community is analysed by planning zones, and the hazards of each zone are identified and ranked by potential severity.[1] The resulting cover serves to define a baseline of operations, identify benchmarks, set levels of service for all parts of a community and measure performance over successive budget years.[3]

The approach bears on a question debated in fire service planning. Granito (2008) asks whether communities should assess their own needs and resources and provide individual answers, or whether national standards should be applied.[13] Johnson and Price (2008) state that each community must decide its desired response and travel times.[14] They present the CFAI process as another guideline next to NFPA 1710, NFPA 1720 and NFPA 1221, the three NFPA standards with time requirements.[5] Granito also quotes a summary of a 2003 UK white paper on integrated risk management. Under it, fire and rescue authorities create local plans based on local risks instead of the old national standardisation of response.[15]

The standard of cover also links to wider planning. Jenaway (2008) lists the department's standard of response cover among the key issues that a strategic plan should identify and analyse.[10] A community risk assessment should categorise significant events in the jurisdiction so that they can be used in determining standards of coverage.[16] Developing a standard of response cover is not quick or easy, but Jenaway calls it valuable and says it should already be in place.[3]

The process step by step

The two handbook chapters list the steps slightly differently. Jenaway (2008) gives eight components, Johnson and Price (2008) nine parts. The nine-part list groups the risk and service steps differently, includes prevention and mitigation and an overall evaluation, and names the reliability and performance steps as historical studies.[3][5]

Flowchart of nine steps from existing deployment and risk assessment through distribution, concentration and reliability to overall evaluation
The standards of response coverage process in nine parts, with the corresponding components of the eight-part list.
Jenaway (2008), p. 12-47 Johnson and Price (2008), p. 12-220
1. Existing deployment 1. Existing deployment
2. Risk assessment 2. Community outcome expectations
3. Risk expectations 3. Community risk assessment
4. Service level objectives 4. Distribution study
5. Distribution study 5. Concentration study
6. Concentration study 6. Historical reliability
7. Reliability study 7. Historical response effectiveness study
8. Performance study 8. Prevention and mitigation
9. Overall evaluation

The existing deployment is mapped, measured and understood first, whatever its origin, for example requirements of the Insurance Services Office (ISO) or past community growth.[3] This helps clarify the department's total reflex and coverage capability.[3] Johnson and Price (2008) add a review of past decisions: why the stations are where they are, why equipment was bought, and whether those decisions can be changed.[5]

The risk steps follow. A risk assessment requires the department to understand fire flow demand and capability, the probability of an emergency, and the consequences for life safety and the economy.[3] Structure fire risk might be classified from fire flow and code compliance into classes such as low, moderate and maximum risk. Many communities may treat most residential areas as moderate or typical risk, and responses may differ between urban, suburban, rural and remote areas.[17] Van Rossum (2027) describes such risk classes, for example from very low to very high, as typical of the qualitative approach in fire safety engineering, which is useful where numerical data are scarce.[18] Community outcome expectations cover fires, natural and man-made disasters, EMS, heavy rescue, hazardous materials, aircraft and water incidents.[5]

The distribution study analyses the geographic spread of first-due resources. Its measures are left to the department and might be the percentage of square miles, of equally sized analysis areas or of road miles.[3] It asks where the first-due resources are located, the central question of a fire station location study.[7] The concentration study asks where incidents cluster and whether the first-alarm assignment, or effective response force, can be assembled there in time. The force should be able to stop the escalation of the emergency for the risk posed.[3][7]

Three small schematic maps showing first-due areas, overlapping reach of several stations, and cover when one station is busy
Distribution (first-due areas), concentration (several stations reaching one area to form an effective response force) and reliability (cover when a unit is committed).

The reliability study tests the cover under load. It requires a historical measure of performance, resource exhaustion and relocation practice, and asks whether call stacking or simultaneous calls occur in particular areas.[3][7] The performance or historical response effectiveness study asks what percentage of compliance the existing system delivers. It draws on existing cover documents, risk assessments, historical performance and cost-benefit evaluations.[3][7]

Prevention and mitigation is the eighth part in the Johnson and Price list. It asks whether tactics can strategically affect the outcome of events. Johnson and Price report that the UK National Plan of 2004 found that, without prevention and mitigation, the level of safety for responders and the public would reach a plateau.[7] Analysing risk and possible strategic actions may prevent some incidents and limit the severity of others.[7] Kirtley (2008a) counts emergency response itself among the five mitigation strategies of community risk reduction, with education, engineering, enforcement and economic incentives.[19]

Writing the cover statement

Service level objectives turn the analysis into targets. They require the department to assemble data on fire growth and flashover, EMS and special service needs, reflex and response times, critical tasks and the effective response force.[3] CFAI examples quoted by Jenaway (2008) include: "For 90% of all incidents, the first arriving unit shall arrive within five minutes total reflex time (or travel time)". The first arriving unit shall be capable of advancing the first line for fire control, starting rescue or providing basic life support.[3] The earlier risk expectations step gives a structure fire objective as an example. It is to stop the development of a moderate fire risk, search and rescue as required, and confine damage as close to the room of origin as possible.[3]

The overall evaluation proposes cover statements by risk type. Johnson and Price (2008) quote a CFAI example. In 90 percent of incidents the first-due unit arrives within 4 minutes of travel or 6 minutes of total reflex time, able to advance the first line, start rescue or provide basic life support. In a moderate risk area, an effective response force arrives within 8 minutes of travel or 10 minutes of total reflex time, 90 percent of the time. It must be able to deliver 1,500 gallons per minute (about 5,700 L/min) for fire fighting or to handle a five-patient medical incident.[2]

In both examples the total reflex objective is 2 minutes longer than the travel objective. The chapter defines total reflex time as including access and setup after arrival, although these examples express it as an arrival objective. The 2-minute difference is not assigned to particular steps.[20][2]

Paired bars show travel times of 4 and 8 minutes against total reflex times of 6 and 10 minutes for the two response forces
Example cover statement: the first-due unit within 4 minutes of travel (6 minutes total reflex time) and the effective response force within 8 minutes of travel (10 minutes), each in 90 percent of incidents.

As an illustration of what such a statement implies, consider a rule of thumb from Granito (2008). It provides one company for each 250 gpm (about 950 L/min) needed in an interior attack, plus personnel for rescue and other simultaneous tasks.[21] Applied to the 1,500 gpm in the example, the rule suggests about six companies arriving within the 8-minute travel window. Granito's typical initial attack capability for low-hazard occupancies is at least 2 pumpers, 1 ladder truck and 14 fire fighters with a chief officer, plus a safety officer and a rapid intervention team. For high-hazard occupancies he gives at least 4 pumpers, 2 ladder trucks and 24 fire fighters with two chief officers, plus one or more safety officers and rapid intervention teams.[22]

Bar chart of minimum fire fighters in a typical initial attack: rural 12, low hazard 14, medium 16, high hazard 24, plus chief officers
Typical initial attack capability by occupancy: minimum fire fighters plus chief officers, each also with a safety officer and a rapid intervention team.

From cover to staffing

Denlinger (2008) names four elements of a department's standards of response coverage that influence required staffing. These are the on-scene operations, including fire flow and life safety tasks, and the critical tasks that must be done in time to control a fire before flashover. The third is an adequate effective response force, the minimum staffing and equipment needed for those tasks, and the fourth the ability to reach the scene within a maximum total reflex time.[6] The primary goal is to arrive within the time allotted by the response standard with enough well-trained and equipped personnel.[6] These questions belong to fire company staffing. Granito (2008) notes that, since 1995, OSHA and NFPA documents have called for at least four trained personnel at a structure fire before an interior attack, except in the most extenuating circumstances.[23]

Denlinger also shows how an on-duty requirement becomes a staffing requirement. Once the cover fixes how many people must be on duty, the staffing total follows from the number of tours of duty to be filled and the tours each person actually works. As an illustration of his calculation, the staff needed equals the positions to be covered times the tours per position per year, divided by the average tours worked per person:[6]

Nstaff=ndutykdw

Symbol Description Unit
Nstaff Number of officers and fire fighters to employ persons
nduty Positions that must be staffed at all times persons
k Tours of duty per position per day 1/day
d Days per year day
w Average tours actually worked per person per year tours

In Denlinger's worked example, a community decides that at least 58 officers and fire fighters must be on duty at all times, with day and night shifts giving two tours per position per day. This requires 58 × 2 × 365 = 42,340 tours a year. Because of leave and other absences, each person works on average 146.5 tours a year, so 42,340 / 146.5 = 289 personnel are needed.[6] He adds that a 42-hour week generally requires five persons per position, so a company of 20 is needed to keep an average of four on duty.[6]

Measuring compliance

Cover statements are written as the share of incidents in which a target is met, typically 90 percent. NFPA 1710, as described by Johnson and Price (2008), likewise requires a performance objective of not less than 90 percent for each time objective.[5] As an illustration, let N be the number of incidents in a reporting period, t an incident's measured response time and Tobj the adopted time objective. The compliance fraction is:

f=N(t≤Tobj)N

The historical response effectiveness study compares this fraction with the adopted goals, for example f≥0.90 for a 90-percent objective.[7] An example performance report in Cline (2008) shows the difference between an average and a fraction. With a goal of 4 minutes or less in 90 percent of responses, the average was 3 minutes 52 seconds, but only 69 percent of responses arrived within 4 minutes.[24] The example therefore misses its operational goal by 21 percentage points despite an average below the target. Cline lists dispatch, turnout and travel time as separate measures for fire service performance measurement.[25]

Krakeel (2008) stresses that compliance with performance measures can occur only when the whole system is coordinated. In EMS, every participant from dispatch through definitive care must recognise its contribution.[4] Benchmarking against other communities also requires caution, because the number of local variables can be so high that comparisons become confusing.[12]

Relation to other approaches and limits

Standards of cover sit beside two other US reference systems of the period. The NFPA deployment standards set fixed time objectives: for career departments, NFPA 1710 sets 4 minutes for the first engine and 8 minutes for the full first alarm.[5] The ISO Fire Suppression Rating Schedule grades the fire department, water supply and alarm handling of a municipality for insurance purposes.[26] It checks, for example, whether built-on areas have an engine company within 1.5 mi (2.4 km) and a ladder company within 2.5 mi (4 km).[27] In a cover, by contrast, the department proposes its own statements by risk type after studying its community.[2]

The level of cover also matters to fire engineers designing buildings. The International Fire Engineering Guidelines (2005) note that much of the input for analysing fire service intervention depends on the level of fire service cover and operational practice. This should be discussed with the fire service at the design brief stage.[28] Donegan (2002) uses the siting of a new fire station as an example of a decision with conflicting objectives: minimum cost, minimum risk and minimum travel distance. Such a problem never has a single correct solution, although its analysis can give stakeholders considerable insight.[29]

The process has practical limits. Granito (2008) calls local data collection and information management vital to planning.[30] The targets remain a local policy choice that balances service expectations against what a community can afford.[14] External consultants, rarely used before the 1990s, were by 2008 involved in decisions such as station placement and workload evaluation. Jenaway (2008) advises a defined scope of work, timelines, deliverables and costs, and consultants experienced with the type of community being analysed.[31] The process and example statements described here are those of the CFAI documents of 2003 as reported in the 2008 handbook.

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 Jenaway (2008), p. 12-46.
  2. ↑ 2.0 2.1 2.2 2.3 Johnson and Price (2008), p. 12-222.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 Jenaway (2008), p. 12-47.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 Krakeel (2008), p. 13-154.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Johnson and Price (2008), p. 12-220.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 6.5 Denlinger (2008), p. 12-73.
  7. ↑ 7.0 7.1 7.2 7.3 7.4 7.5 7.6 7.7 Johnson and Price (2008), p. 12-221.
  8. ↑ Jenaway (2008), p. 12-50.
  9. ↑ Johnson and Price (2008), p. 12-231.
  10. ↑ 10.0 10.1 Jenaway (2008), p. 12-43.
  11. ↑ Krakeel (2008), pp. 13-149, 13-157.
  12. ↑ 12.0 12.1 Granito (2008), p. 12-7.
  13. ↑ Granito (2008), p. 12-4.
  14. ↑ 14.0 14.1 Johnson and Price (2008), p. 12-219.
  15. ↑ Granito (2008), p. 12-3.
  16. ↑ Jenaway (2008), p. 12-45.
  17. ↑ Johnson and Price (2008), pp. 12-220–12-221.
  18. ↑ Van Rossum (2027), §1.4.
  19. ↑ Kirtley (2008a), pp. 12-309–12-310.
  20. ↑ Johnson and Price (2008), p. 12-218.
  21. ↑ Granito (2008), p. 12-13.
  22. ↑ Granito (2008), p. 12-12.
  23. ↑ Granito (2008), p. 12-8.
  24. ↑ Cline (2008), p. 12-36.
  25. ↑ Cline (2008), p. 12-37.
  26. ↑ Jenaway (2008), p. 12-48.
  27. ↑ Granito (2008), p. 12-17.
  28. ↑ National Research Council of Canada et al. (2005), p. 1.9-5.
  29. ↑ Donegan (2002), p. 5-13.
  30. ↑ Granito (2008), p. 12-6.
  31. ↑ Jenaway (2008), p. 12-49.

References

  • Cline, D. (2008). Organizational benchmarking and performance evaluation. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-23–12-40). National Fire Protection Association.
  • Denlinger, R. F. (2008). Managing fire-rescue departments. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-51–12-78). National Fire Protection Association.
  • Donegan, H. A. (2002). Decision analysis. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 5-8–5-23). National Fire Protection Association; Society of Fire Protection Engineers.
  • Granito, J. A. (2008). Planning for public fire-rescue protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-3–12-22). National Fire Protection Association.
  • Jenaway, W. F. (2008). Needs assessment and hazard analysis. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-41–12-50). National Fire Protection Association.
  • Johnson, R., & Price, M. (2008). GIS for fire station locations and response protocols. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-215–12-231). National Fire Protection Association.
  • Kirtley, E. (2008a). Community risk reduction. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-309–12-315). National Fire Protection Association.
  • Krakeel, J. J. (2008). Emergency medical services and the fire department. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-145–13-161). National Fire Protection Association.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.