Fse-structural-firefighting-protective-clothing-v3.svg (SVG file, nominally 1,000 × 760 pixels, file size: 11 KB)

Summary

Principle of the thermal protective performance (TPP) test: a horizontal specimen is exposed to 84 kW/m² from burners and quartz tubes, and a copper calorimeter above it measures the heat passing through to predict time to pain and to a second-degree burn.

Original illustration for Structural firefighting protective clothing.

  • Alt text: Side section of TPP test: burners and quartz lamps below, horizontal fabric specimen, copper calorimeter above, water-cooled shutter