Contents
Fse-hydraulic-calculation-v3.svg (SVG file, nominally 900 × 600 pixels, file size: 7 KB)
Summary
Two sprinklers at the end of a branch line. Friction in 3.66 m of pipe adds 0.17 bar, so the second sprinkler discharges more than the end sprinkler.
Original illustration for Hydraulic calculation, level 4 Expert.
- Alt text: Side view of a pipe with two sprinklers 3.66 m apart: the end sprinkler gets 1.40 bar and 95 L/min, the second 1.56 bar and 101 L/min.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.