Summary

Corrected dose-fraction calculation for two floor coverings; the source table has a factor-ten mass discrepancy.

Original illustration for Smoke toxicity test.

  • Alt text: Calculated dose fraction rises with the cube of time; A crosses 1 at 13.2 minutes and B at 16.6 minutes under the source's stated area density.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.