Contents
Fse-mattress-flammability-v3.svg (SVG file, nominally 1,270 × 740 pixels, file size: 6 KB)
Summary
Simulated-bedclothes exposure in the United States open-flame mattress test (16 CFR 1633): a T-head burner of 18 kW above the top surface and one of 9 kW beside the side. Pass limits: peak heat release rate 200 kW, 15 MJ in the first 10 minutes.
Original illustration for Mattress flammability.
- Alt text: Side and top views of a mattress on its foundation with an 18 kW T-burner above the top and a 9 kW T-burner beside the side.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 07:55, 8 November 2026 | 1,270 × 740 (6 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: