Contents
Fse-mattress-flammability-v1.svg (SVG file, nominally 1,350 × 735 pixels, file size: 8 KB)
Summary
Peak full-scale heat release rate of mattresses with a complete set of bedding, ignited with a wastebasket, by padding and ticking material. Reference lines mark the United States limits of California TB 129 (100 kW) and 16 CFR 1633 (200 kW). Based on Babrauskas (2002b), p. 3-21 and Babrauskas (2008b), pp. 6-116–6-117.
Original illustration for Mattress flammability.
- Source basis: Babrauskas (2002b), p. 3-21 (Table 3-1.8); Babrauskas (2008b), pp. 6-116–6-117 (limits); data, not a copied figure
- Alt text: Bar chart of peak heat release rate of seven mattresses with bedding, from 40 kW for cotton/jute to 2,720 kW for latex foam, with lines at 100 and 200 kW.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 07:55, 8 November 2026 | 1,350 × 735 (8 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: