Skip to content
From Fire Safety Academy Wiki
Revision as of 04:34, 8 November 2026 by Peter (talk | contribs) (FSE wiki: Source-checked mattress fire data, historical scope and Heskestad conversion (written by Claude Opus 5.5))
Contents
  1. 1Fire experience
  2. 2How mattresses ignite and burn
  3. 3Cigarette ignition test
  4. 4Open-flame tests and regulation
  5. 5Predicting mattress fires from bench-scale tests
    1. 5.1Worked example
  6. 6Barriers and materials
  7. 7Institutional and detention use
  8. 8Limits and common misconceptions
  9. 9See also
  10. 10Notes
  11. 11References

Mattress flammability is the tendency of a mattress to ignite from a cigarette or a flame, and the size and speed of the fire it then produces. It is usually described by two separate properties. One is resistance to smouldering ignition by a lit cigarette; the other is the heat release rate of the mattress under a large open flame, such as burning bedclothes.[1][2] Mattresses and bedding are among the leading items first ignited in fatal home fires. In the United States in 1999 to 2002 they accounted for 14 % of home fire deaths, the second largest share of any burnable item after upholstered furniture.[3]

As described in the 2008 edition of the Fire Protection Handbook, United States mattresses made since 1973 had to pass a federal cigarette test, 16 CFR 1632. A second federal rule, 16 CFR 1633, took effect in July 2007. It limited open-flame heat release to a 200 kW peak and 15 MJ total in the first 10 minutes.[1][4] Mattresses differ from upholstered seating: their flat surfaces resist cigarettes better, but sheets and blankets on a bed can cover a cigarette or feed a larger flame. Their burning also depends strongly on radiation from the room around them.[5][6] Mattress fires are a particular concern in prisons, where mattresses and bedding are the fuels most readily available to inmates, and in health care.[7][8]

Fire experience

Home fires that began with mattresses or bedding fell from 61,100 in 1980 to 14,300 in 2002, and civilian deaths from 937 to 442.[9] In 1999 to 2002 these fires averaged 17,500 a year, with 413 civilian deaths, 1,990 injuries and $357 million in direct property damage.[9] They were 5 % of home fire incidents but caused 14 % of the deaths and 13 % of the injuries.[3] The decline has been attributed in part to regulations that introduced improved materials, and the federal law on mattress construction reduced their ignitability by lighted tobacco.[10][11]

Cigarettes started 22 % of these fires in 1999 to 2002 but caused 44 % of the deaths. Lighters and matches together started another 28 %.[12][13] In the then-small NFIRS 5.0 subset, playing with a heat source and heat sources too close to the bed were each cited in 24 % of the fires. Abandoned or discarded materials, such as a lit cigarette, were cited in 16 % of these fires and 32 % of the deaths. The handbook warns that the subset may not be representative.[14] NFPA statistics group mattresses and bedding together because they function as one system.[15]

How mattresses ignite and burn

A cigarette on a mattress usually starts smouldering. Flat mattress surfaces are less likely to ignite from a cigarette than the crevices of upholstered furniture. On a bed, however, a cigarette may be covered by sheets, blankets or pillows, which raises the probability of ignition.[5]

In room tests, a cigarette-initiated smoulder in a cotton mattress spread radially at about 6.3 × 10⁻⁵ m/s, or about 3.8 mm per minute. In two of five tests the smoulder turned to flaming after 65 to 80 minutes, close to the time at which the carbon monoxide exposure was estimated to be lethal.[16] A review of such tests concluded that a lethal carbon monoxide dose and a transition to flaming were about equally likely between 1 and 2½ hours after the cigarette was placed.[16] Mattress materials let fire penetrate deeply and smoulder for a long time, which makes extinguishment difficult.[10]

With a flame, the bedding usually matters more than the mattress. An extensive study at the National Institute of Standards and Technology (NIST) in the 1970s showed that the bedding on a bed is the "driving force" for flame spread and sustained burning of the mattress. In the absence of bedding a mattress fire may die out, while the same mattress may burn vigorously under bedclothes.[17] Sheets and blankets may also ignite from flames more readily than mattresses and then expose the mattress to a much more severe fire. For these reasons relevant tests are harder to develop for mattresses than for upholstered furniture.[5][6]

Mattresses also respond strongly to their surroundings. A mattress and a chair with the same heat release rate in a very large space may behave quite differently in a small room, where the mattress is likely to burn more severely.[6] The SFPE Handbook compares this behaviour to that of liquid pools: a mattress may not have a single heat release rate, because the value depends on the room.[18] For chairs the room raises the burning rate by about 20 % up to 1 MW, whereas for mattresses a room effect appears at much lower heat release rates.[19] Some research indicates that the heat release rate of objects such as mattresses can double in a fire after flashover.[20]

NFPA 921 (2004 edition) lists 40 to 970 kW for cotton mattresses of 11.8 to 13.2 kg (26 to 29 lb). For polyurethane foam mattresses of 3.2 to 14.1 kg (7 to 31 lb) it lists 810 to 2,630 kW.[21] In tests with full bedding, ignited with a wastebasket, a 14 kg polyurethane mattress with a PVC cover peaked at 2,630 kW. A neoprene mattress with a fire-retardant cotton cover peaked at only 70 kW.[22] In fire growth terms, the medium t-squared curve is described as typical of mattresses, and some older types are ultrafast.[23] A single horizontal polyurethane mattress has a growth time of 120 s to reach 1,055 kW (1,000 Btu/s), faster than the 300 s of the medium curve.[24]

Cigarette ignition test

As described in the 2008 handbook, United States mattresses made since June 1973 were subject to the cigarette-ignition test in Title 16 of the Code of Federal Regulations, Part 1632. The method was developed by the National Bureau of Standards, now NIST, and taken over by the Consumer Product Safety Commission (CPSC). It was still often known by its original designation, FF 4-72.[1] The test is run on a full-size mattress. Nine cigarettes are placed on the bare mattress and nine more between two sheets laid on it.[1]

The cigarettes burn in a draught-protected environment on the smooth surface, the tape edge and any quilted or tufted locations. A test location passes if the char length is not more than 50.8 mm (2 in.) in any direction from the nearest point of the cigarette.[4] Babrauskas (2008b) describes a filterless 85 mm commercial cigarette as the test cigarette then used in United States smouldering tests, representative of many brands in its tendency to ignite.[25] A United States Department of Agriculture test series found that mattresses containing polyurethane foam easily comply with the federal cigarette standard but present a significant hazard when the ignition source is an open flame. The cigarette test does not indicate resistance to open flames or the intensity of the resulting fire.[7]

Open-flame tests and regulation

Before the federal rule, California led open-flame testing in the United States. Technical Bulletin 121 (TB 121), a large-scale test for prison mattresses, uses the same room as the furniture test TB 133, with a wastebasket placed underneath the mattress. TB 129, a less severe test for other institutional occupancies, uses a gas burner along the mattress edge and a pass/fail limit of 100 kW. It has been adopted as ASTM E1590.[17] ASTM E1590 measures the heat release rate of full-scale mattresses, and ASTM E1474 the heat release rate of mattress composites in a bench-scale calorimeter.[26][27] Outside the United States, Babrauskas lists British Standard BS 6807 and the Nordic test NT FIRE 036 for mattresses.[1]

In 1991, full-scale tests of bare mattresses by the California Bureau of Home Furnishings and Thermal Insulation let some specimens pass easily, although they might not have behaved similarly in real life. The industry association International Sleep Products Association (ISPA) then sponsored NIST research on a test that accounts for bedding.[17] Identical bedclothes could not be guaranteed over the long term, so NIST replaced them with two "T-head" gas burners. The top burner runs at 18 kW and the side burner at 9 kW.[17] The criterion is not non-ignition but a low heat release rate. This is the harder requirement, because it is easier to resist a small flame than to show little fire development under a sizable one.[2]

A California law of August 2001 required all mattresses sold in the state from 1 January 2004 to resist open flames. The resulting standard, TB 603, essentially implements the ISPA and NIST protocol.[2] It permits testing in an open calorimeter or in a test room. The California burn room measures 3.05 by 3.66 m (10 by 12 ft) and the ASTM room 2.44 by 3.66 m (8 by 12 ft). CPSC adopted essentially the same method as 16 CFR 1633, issued in February 2006 and effective on 1 July 2007.[17][2]

CPSC kept only the open calorimeter and the California room, retained the 200 kW peak and cut the 10-minute total heat release from 25 to 15 MJ.[2] The test applies to a twin-size or larger mattress, and the peak is measured over 30 minutes.[4] CPSC considered it the first regulation in its history with an impact of more than $100 million on the national economy.[17]

The 15 MJ limit is strict. Spread over the first 600 s it corresponds to a mean heat release rate of only 25 kW, whereas California's limit of 25 MJ corresponds to about 42 kW. The rule is in addition to the existing cigarette requirement.[2] A companion draft for bedding, TB 604, was published in 2004. By the 2008 edition of the Fire Protection Handbook it had not been finalised, and it relied on simple weighing rather than heat release.[2]

Predicting mattress fires from bench-scale tests

Predicting the full-scale heat release rate of a mattress from cone calorimeter data is difficult, partly because of the strong room effect.[18] One older data set showed an abrupt transition. Mattresses with a 180 s average bench-scale heat release rate below 165 kW/m² led to room fires of less than 100 kW, whereas those above it generally led to fires of 1 to 2 MW.[22] In the European CBUF research programme, mattresses were sorted into propagating fires, in which the mattress is consumed by flaming in a relatively short time, and nonpropagating fires of trivial hazard.[28] Composites are tested at 35 kW/m² in a standard 50 mm thickness, so a thickness factor accounts for thin mattresses:

TF=min⁡(d50,1.0)

With this factor, the fire is predicted to be nonpropagating, with a peak below 80 kW, if both of the following conditions hold. Otherwise it is predicted to propagate, but the rule does not predict a particular peak. In the source's room tests, propagating cases reached up to about 2.5 MW. Only the 180 s average is multiplied by the thickness factor:[28]

q˙′'180⋅TF<100 kW/m2andq˙′'60<250 kW/m2

Symbol Description Unit
TF Thickness factor –
d Mattress thickness; with innersprings, measured from the top of the mattress down to the top of the springs mm
q˙′'60 Cone heat release metric labelled q″60 in the source, measured at 35 kW/m²; its exact time basis is not specified there kW/m²
q˙′'180 Cone calorimeter heat release rate averaged over 180 s, at 35 kW/m² kW/m²

The rule does not give a heat release rate for propagating fires, and it was derived from CBUF tests without bedding, using a square burner on the top surface.[22][28] Its two conditions reflect the abrupt change from trivial fires to flashover seen in earlier studies, while avoiding the non-predictions of a simple correlation. A more sophisticated CBUF mattress model by Baroudi and co-workers exists but is not easy to use.[28]

Worked example

Two CBUF mattresses had the same cone results, a q″60 value of 111 kW/m² and a 180 s average of 118 kW/m², but different thicknesses.[28] The first had innersprings and a thickness of 20 mm above the springs, so TF = 20/50 = 0.40. Then 118 × 0.40 = 47.2 kW/m², below 100, and 111 is below 250, so the rule predicts a nonpropagating fire. The measured peak in the furniture calorimeter was 47 kW.[28]

The second was 90 mm thick without springs, so TF = 1.00 and 118 × 1.00 = 118 kW/m², above 100. The rule predicts a propagating fire, and the measured peak was 275 kW.[28] A third mattress shows the second condition. Its thickness product was only 64 kW/m², but its q″60 value of 327 kW/m² exceeded 250. It was predicted to propagate and peaked at 348 kW in the calorimeter and 471 kW in the room.[28]

Barriers and materials

Fire barriers show the largest gains. In one test a commercial mattress that peaked at 1,900 kW was fitted with an add-on barrier cover of the kind a householder could buy, and its peak fell to about 100 kW. Mattresses made with a barrier in the factory gave peaks of 20 to 40 kW.[29] A likely common solution for meeting 16 CFR 1633 was an interliner "bag", a fire barrier that encapsulates the padding.[2]

Padding and ticking strongly affect the result. Mattresses contain fewer materials than upholstered furniture, and older materials such as cotton batting, latex foam and vegetable fibres could still be found in some products.[6] In the full-bedding tests, latex foam and polyurethane foam with PVC or rayon ticking peaked at 760 to 2,720 kW. Neoprene and cotton-and-jute paddings with fire-retardant cotton ticking peaked at 70 and 40 kW.[22]

In 1977 the National Bureau of Standards (NBS) ranked mattresses in four groups of increasing hazard. Two treated cotton-batting mattresses stayed within all tenability criteria for the 30-minute test, and two neoprene mattresses exceeded only the smoke obscuration criterion.[30] Three polyurethane foam-core mattresses and one of mixed fibres exceeded all criteria without full room involvement. A styrene-butadiene latex mattress and a polyurethane foam mattress exceeded all criteria.[30]

Institutional and detention use

In a detention or correctional occupancy, mattresses and bedding are the fuels most readily available to inmates and most frequently involved in fires. Certain polyurethane foam mattresses can support fast fire development, high heat release and heavy smoke production.[7] According to Jaeger, the NBS tests indicate that cotton treated with boric acid is the best padding for correctional use. It passes the federal cigarette test and performs well against open flames, burning much more slowly than urethane foam.[30] Jaeger (2008) reported that operators were reluctant to buy expensive mattresses because inmates often damaged them deliberately; fire-retardant-covered foam or treated-cotton mattresses were then the most common.[30] Hirschler (2008a) describes ASTM F1550 as a test of mattress composites after simulated vandalism for detention use.[26]

Health care fires show how fast a bed fire can grow. In a 1989 nursing home fire in Norfolk that killed 12 people, the fire began in a foam plastic decubitus (pressure-sore) pad on a mattress and reached flashover in less than 5 minutes.[8] In patient rooms, polyurethane foam mattresses and similar items may not change how long a fire burns, but they affect how fast it grows.[8]

In the United States, any restrictions on mattresses in the Life Safety Code are found in its occupancy chapters, as described in the 2008 edition of the Fire Protection Handbook. Few occupancies have them, and they apply only to new mattresses.[31] For United States board and care facilities, Jose (2008) described NFPA test criteria for new mattresses, with an exception for residents' own mattresses in their sleeping room if a smoke alarm was installed there.[32] Institutional mattresses have long been expected to show low heat release rates even under large flames. Because the 2007 federal rule for residential mattresses is almost as strict, unsuitable mattresses were expected to disappear from the institutional market.[29]

Limits and common misconceptions

A mattress that resists cigarettes is not necessarily safe against flames, since polyurethane foam mattresses pass the cigarette test easily yet burn vigorously from an open flame.[7] Tests on bare mattresses can be unrealistically benign, because bedding is the main driver of a real bed fire.[17] The burners of 16 CFR 1633 are a substitute for bedclothes, and the rule does not cover the bedding itself, which may still burn with a high heat release rate.[2]

Test configuration matters as well. The open calorimeter and the burn room are not equivalent, because radiant heating from the upper part of a room greatly increases mattress burning. Manufacturers were therefore expected to test in the open calorimeter.[2] Fire data change slowly, because a mattress is a long-lived product. A safer design does not bring the immediate drop in deaths seen with quickly replaced products such as disposable lighters.[33]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 Babrauskas (2008b), p. 6-111.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 Babrauskas (2008b), p. 6-117.
  3. ↑ 3.0 3.1 Babrauskas (2008b), p. 6-103.
  4. ↑ 4.0 4.1 4.2 Stull and Chines (2008), p. 6-94.
  5. ↑ 5.0 5.1 5.2 Babrauskas (2008b), p. 6-107.
  6. ↑ 6.0 6.1 6.2 6.3 Babrauskas (2008b), p. 6-109.
  7. ↑ 7.0 7.1 7.2 7.3 Jaeger (2008), p. 20-134.
  8. ↑ 8.0 8.1 8.2 O'Connor (2008), p. 20-144.
  9. ↑ 9.0 9.1 Babrauskas (2008b), p. 6-104.
  10. ↑ 10.0 10.1 Stull and Chines (2008), p. 6-88.
  11. ↑ Hall and Cote (2008), p. 3-14.
  12. ↑ Babrauskas (2008b), p. 6-107, Table 6.6.6.
  13. ↑ Stull and Chines (2008), p. 6-87.
  14. ↑ Babrauskas (2008b), p. 6-108.
  15. ↑ Ahrens et al. (2008), p. 3-73.
  16. ↑ 16.0 16.1 Ohlemiller (2002), p. 2-206.
  17. ↑ 17.0 17.1 17.2 17.3 17.4 17.5 17.6 Babrauskas (2008b), p. 6-116.
  18. ↑ 18.0 18.1 Babrauskas (2002b), p. 3-20.
  19. ↑ Babrauskas (2002b), p. 3-1.
  20. ↑ Custer (2008), p. 2-57.
  21. ↑ NFPA 921 (2004), as cited in Custer (2008), p. 2-50.
  22. ↑ 22.0 22.1 22.2 22.3 Babrauskas (2002b), p. 3-21.
  23. ↑ Hurley and Bukowski (2008), p. 3-127.
  24. ↑ Heskestad (2008), pp. 18-61–18-62.
  25. ↑ Babrauskas (2008b), p. 6-112.
  26. ↑ 26.0 26.1 Hirschler (2008a), p. 6-47.
  27. ↑ Hirschler (2008a), p. 6-49.
  28. ↑ 28.0 28.1 28.2 28.3 28.4 28.5 28.6 28.7 Babrauskas (2002b), p. 3-22.
  29. ↑ 29.0 29.1 Babrauskas (2008b), p. 6-126.
  30. ↑ 30.0 30.1 30.2 30.3 Jaeger (2008), p. 20-135.
  31. ↑ Lathrop (2008a), p. 4-77.
  32. ↑ Jose (2008), p. 20-19.
  33. ↑ Hall (2008), p. 5-110.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Babrauskas, V. (2002b). Heat release rates. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 3-1–3-37). National Fire Protection Association; Society of Fire Protection Engineers.
  • Babrauskas, V. (2008b). Upholstered furniture and mattresses. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-103–6-128). National Fire Protection Association.
  • Custer, R. L. P. (2008). Dynamics of compartment fire growth. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-49–2-58). National Fire Protection Association.
  • Hall, J. R., Jr. (2008). Using data for public education planning and decision making. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-103–5-118). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Heskestad, G. (2008). Venting practices. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 18-57–18-72). National Fire Protection Association.
  • Hirschler, M. M. (2008a). Concepts and protocols of fire testing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-35–6-60). National Fire Protection Association.
  • Hurley, M. J., & Bukowski, R. W. (2008). Fire hazard analysis techniques. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-121–3-134). National Fire Protection Association.
  • Jaeger, T. W. (2008). Detention and correctional occupancies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-129–20-138). National Fire Protection Association.
  • Jose, P. R. (2008). Board and care facilities. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-15–20-21). National Fire Protection Association.
  • Lathrop, J. K. (2008a). Concepts of egress design. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 4-69–4-91). National Fire Protection Association.
  • O'Connor, D. J. (2008). Health care occupancies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-139–20-155). National Fire Protection Association.
  • Ohlemiller, T. J. (2002). Smoldering combustion. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-200–2-210). National Fire Protection Association; Society of Fire Protection Engineers.
  • Stull, J. O., & Chines, S. A. (2008). Fibers and textiles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-75–6-102). National Fire Protection Association.