A fire-safe cigarette is a cigarette designed to have a reduced tendency to keep burning when it is left unattended. It is therefore less likely to ignite the furniture or bedding on which it is dropped.[1] Such cigarettes are also called reduced-ignition-strength cigarettes, and fire statistics analysts sometimes speak of self-extinguishing cigarettes.[2][3] The idea is to regulate the ignition source instead of the fuel that it ignites.[1]

In United States home-fire estimates for 1999–2002, cigarettes were the leading heat source in fatal fires that began with upholstered furniture or mattresses.[4][5] Among reported United States structure fires in 1999–2002, smoking materials caused more than a quarter of civilian fire deaths; most began with upholstered furniture, mattresses or bedding.[6] Research by the National Institute of Standards and Technology (NIST), commissioned under two federal acts of 1984 and 1990, concluded that such cigarettes were feasible and practicable. NIST also developed the test method that became ASTM E2187 for measuring the ignition strength of cigarettes.[1] New York became the first state to require compliant cigarettes, from June 2004, followed by Canada in 2005 and by several other states.[1] Fire-safe cigarettes reduce the probability of ignition but do not remove it, and they act only on fires started by cigarettes.[1][3]

How cigarettes start fires

A burning cigarette is a familiar example of true smouldering, a slow, low-temperature, flameless combustion in which oxygen attacks the surface of a solid fuel. It is also one of the most common initiators of smouldering in other materials, especially upholstery and bedding.[7] Tobacco, like other cellulosic material, forms a char when heated. This char has a high heat of oxidation and reacts readily with oxygen at moderate temperatures, helped by alkali metal impurities present in plant material.[7] The finely divided tobacco gives a large surface area, lets oxygen reach the reaction zone and insulates the burning zone, so combustion continues despite a low heat release rate.[7]

The heat output of a cigarette is very small. A cigarette of 1.1 g, not puffed and lying on a solid surface, releases about 5 W for about 1,200 s, roughly 6 kJ in total.[8][9] Its maximum heat flux is nevertheless high, about 42 kW/m² for a bone-dry cigarette and 35 kW/m² for one conditioned to 50 % relative humidity.[8] In open air a horizontal cigarette smoulders along its length at about 3.0 to 5.0 × 10⁻³ cm/s, or 1.8 to 3.0 mm per minute, with peak temperatures of about 820 °C.[10] During a draw, air flows in the same direction as the burning front; this is the most familiar example of what is called forward smoulder.[11]

A cigarette dropped on a chair or bed can pass its smouldering on to the fabric and padding. A glowing cigarette may start smouldering that continues for a long time before flaming begins, producing little heat but considerable amounts of toxic gas.[12] The crevices of upholstered furniture are especially vulnerable, and on a bed a cigarette may be covered by sheets or blankets.[13] The smouldering-to-flaming transition does not always occur. When it does, times of 22 minutes to several hours after the cigarette was placed have been reported.[14] Because such fires can smoulder for hours before open burning, many fatal smoking fires in dwellings occur at night while everyone is asleep.[15]

The fire problem addressed

A smoking-material fire causes far more deaths than its share of fires suggests. In United States homes in 1999 to 2002, cigarettes started 34 % of the fires that began with upholstered furniture but caused 49 % of the deaths in them.[4] For mattresses and bedding the shares were 22 % of the fires and 44 % of the deaths.[5] Together these cigarette fires caused about 457 deaths a year, close to half of the 974 annual home fire deaths in fires that began with these items.[4][5]

In one- and two-family dwellings, smoking materials were the leading cause of fatal fires, although they ranked only fifth as a cause of all fires.[15] Gamache (2008) reported that adults aged 65 or older had the highest death rate from cigarette fires, although they were only half as likely to smoke as younger adults. The chapter recommended advocacy for fire-safe cigarette legislation as a priority in efforts to reduce fire deaths among older adults.[16]

The problem has long been attacked from the fuel side. In the United States, a federal law on mattress flammability and a voluntary programme of the furniture industry have reduced the ignitability of these items by lighted tobacco.[6] According to estimates by the Consumer Product Safety Commission (CPSC), deaths from smouldering ignitions in upholstered furniture fires fell from about 1,000 a year in the early 1980s to about 600 by the mid-1990s. Babrauskas attributes this fall to the voluntary furniture programme, a reduction in smoking, better fire safety education and wider use of smoke alarms.[17] Hall (2008) judged conventional education to have limited or unproven effect on smoking fires and advised that a serious programme consider efforts to pass a state law mandating fire-safe cigarettes.[2]

Analysts stress that cigarettes are not simply "to blame" for these deaths. Many deaths would not have occurred if smokers had avoided smoking in bed and used sturdy ashtrays. Many others would have been avoided if the furniture, bedding and mattresses first ignited had been more ignition resistant, and many might have been prevented by cigarettes designed to self-extinguish more quickly.[18] The choice of how to classify causes should support workable prevention strategies, not an assessment of blame.[18]

Research and test methods

In the United States, two acts of Congress led CPSC to ask NIST to examine the practicability of fire-safe cigarettes. These were the Cigarette Safety Act of 1984 and the Fire Safe Cigarette Act of 1990.[1] In both cases NIST produced extensive studies that clarified many details of the problem. At the end of the second study, the conclusion was that such cigarettes are not only feasible but also practicable.[1] Berkol and co-authors summarise the result as showing that commercial production of a relatively fire-safe cigarette was feasible.[19]

The smouldering cigarette itself had long been studied extensively, mostly in relation to its cyclic, forced air supply during smoking, and its smoulder propagation had been modelled numerically. A considerable amount of empirical data was also available on the tendency of cigarettes to start smouldering in upholstery and bedding.[20] NIST also developed a test method for this purpose, which became ASTM E2187, Standard Test Method for Measuring the Ignition Strength of Cigarettes.[1] Hirschler lists it among the cigarette ignition tests together with NFPA 260, NFPA 261, ASTM E1353 and ASTM E1352.[21] Those other methods test furniture components or mock-ups, not the cigarette.[22] In tests of furniture and mattresses the cigarette is fixed: all United States smouldering ignition tests use a filterless 85 mm commercial cigarette that is representative of many brands in its tendency to ignite.[1]

ASTM E2187 reverses the roles and measures the ignition strength of the cigarette itself.[1] In July 2000, Philip Morris began producing fire-improved Merit cigarettes with a patented paper, PaperSelect, which carries thin bands of less porous paper. These bands act as "speed bumps" that periodically slow down the burning rate.[1] NIST tests showed that the cigarette did have a reduced ignition potential. The probability of ignition was still 3 to 50 %, however, depending on the test substrate.[1]

Legislation and adoption

No federal regulation had been adopted in the United States by the 2008 edition of the Fire Protection Handbook.[19] Faced with having to produce different cigarettes for different states, the largest United States producer, Altria (formerly Philip Morris), took the position that all such cigarettes should be fire safe. Federal legislation followed in April 2002 but had not passed.[23] Regulation therefore developed state by state. Hall argues that the state is the practical level, because such cigarettes cannot be made mandatory, or even available, in a single community.[2]

New York was the first state to require that cigarettes sold there comply with the ASTM standard. Its Fire Safety Standards for Cigarettes took effect on 28 June 2004.[1] Canada then adopted regulations based on the same ASTM standard for the whole country, effective 1 October 2005. Vermont followed on 1 May 2006 and California on 1 January 2007.[1] In March 2006 NFPA launched the Coalition for Fire-Safe Cigarettes, which brought together more than 50 national organisations. It called on manufacturers to produce only cigarettes meeting a standard based on ASTM E2187, and on all states to adopt such standards.[1][16]

Fire-safe cigarette laws in the United States by 2006[1]
State Share of United States population (%) Legislation signed Effective date
New York 6.5 31 December 2003 28 June 2004
Vermont 0.2 17 July 2005 1 May 2006
California 12.2 7 October 2005 1 January 2007
Illinois 4.3 19 May 2006 1 January 2008
New Hampshire 0.4 31 May 2006 1 October 2007
Massachusetts 2.2 8 July 2006 1 January 2008
Total 25.9

Three of these laws were adopted within four months of the coalition's launch.[1] By the end of 2006, six states with about a quarter of the United States population had passed fire-safe cigarette legislation.[16][1] Authors in the 2008 edition of the Fire Protection Handbook expected these laws to bring improvements, including a further decline of fires in hotels and university housing.[6][24]

Effectiveness and limits

A fire-safe cigarette is not a cigarette that cannot start a fire. The Merit cigarette tested by NIST still ignited test substrates with a probability of 3 to 50 %.[1] The term describes only a reduced propensity to keep burning when left unattended.[1] Fires started by lighters, matches, candles or heating equipment are not affected at all. A change to self-extinguishing cigarettes would affect only fires whose heat of ignition was a cigarette.[3] Cigarette lighters and matches together started 28 % of home mattress and bedding fires in 1999 to 2002, more than cigarettes did.[25]

The great advantage of the measure is speed. Changes in cigarettes can be applied to all cigarettes within months, whereas changes in the upholstered furniture that cigarettes ignite may take decades to work through the whole stock in use.[3] A mattress is a long-lived product, so a safer design does not show an immediate effect in the statistics.[26]

The measure also complements, rather than replaces, other protection. Fire-safe cigarettes, child-resistant lighters, and furniture and mattresses that resist cigarette ignition are all examples of safer household products.[27] The victims of such fires are not always, or even usually, the people who started them, and a large minority of smoking-fire deaths occur outside the room of origin. This leaves time and distance for smoke alarms, sprinklers and compartment barriers to act.[28]

Role in fire safety engineering

Cigarette ignition is a standard input to fire scenarios. A possible set of design scenarios for a single-family house, for example, includes a cigarette igniting upholstered furniture in a living room or bedroom as a common smouldering fire. A high-challenge scenario adds a shielded room-corner fire with a substantial initial smouldering period, started by a small flame or a cigarette.[29] Such a fire may show a long incipient period before growth, whereas a flaming fire in the same item may not.[30] Standard t-squared design fires start from a reasonably large flaming source and leave out this incubation period. During it the fire may hardly grow, yet it can produce enough smoke to operate smoke detectors.[31]

For risk and statistical analysis, fire-safe cigarettes are a topic-driven question. A study of the likely impact of a self-extinguishing cigarette has to cover smoking-material fires in all property types, not only homes.[32] Estimating the effect then follows the usual steps of an impact analysis. The size of the target fire problem, the expected percentage reduction, the speed of adoption and the frequency with which the measure is defeated in practice must all be estimated.[33]

Common misconceptions

One misconception is that fire-safe cigarettes go out by themselves under all conditions. The definition given by Babrauskas speaks only of a reduced propensity to continue burning, and test results depend strongly on the substrate.[1] Another is that cigarette-resistant furniture makes fire-safe cigarettes unnecessary, or the reverse. In the analysis of Ahrens and co-authors, safer smoking behaviour, more ignition-resistant furniture and self-extinguishing cigarettes each act on part of the same chain of events.[18]

A third misconception is that smouldering fires are harmless because they are small. Introduction to Fire Safety Engineering distinguishes flaming and smouldering combustion and concentrates on flaming because it poses the most acute danger.[34] Smouldering typically yields a substantially higher conversion of fuel to toxic compounds than flaming, though more slowly, and it provides a path to flaming from heat sources much too weak to cause a flame directly.[7] A cigarette of a few watts can therefore lead, after 22 minutes to several hours, to a flaming fire large enough to cause flashover in a room.[14][8]

See also

Notes

  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 Babrauskas (2008b), p. 6-112.
  2. ↑ 2.0 2.1 2.2 Hall (2008), p. 5-112.
  3. ↑ 3.0 3.1 3.2 3.3 Ahrens et al. (2008), p. 3-90.
  4. ↑ 4.0 4.1 4.2 Babrauskas (2008b), p. 6-106.
  5. ↑ 5.0 5.1 5.2 Babrauskas (2008b), p. 6-107.
  6. ↑ 6.0 6.1 6.2 Hall and Cote (2008), p. 3-14.
  7. ↑ 7.0 7.1 7.2 7.3 Ohlemiller (2002), p. 2-200.
  8. ↑ 8.0 8.1 8.2 Babrauskas (2008b), p. 6-118.
  9. ↑ Karlsson and Quintiere (1999), as cited in Iqbal and Salley (2004), p. 3-2.
  10. ↑ Ohlemiller (2002), p. 2-207.
  11. ↑ Ohlemiller (2002), p. 2-203.
  12. ↑ Iqbal and Salley (2004), p. 6-3.
  13. ↑ Babrauskas (2008b), p. 6-107.
  14. ↑ 14.0 14.1 Babrauskas (2008b), p. 6-109.
  15. ↑ 15.0 15.1 Lathrop (2008b), p. 20-58.
  16. ↑ 16.0 16.1 16.2 Gamache (2008), p. 5-69.
  17. ↑ Babrauskas (2008b), p. 6-113.
  18. ↑ 18.0 18.1 18.2 Ahrens et al. (2008), p. 3-71.
  19. ↑ 19.0 19.1 Berkol et al. (2008), p. 20-26.
  20. ↑ Ohlemiller (2002), p. 2-206.
  21. ↑ Hirschler (2008a), p. 6-38.
  22. ↑ Babrauskas (2008b), p. 6-111.
  23. ↑ Berkol et al. (2008), pp. 20-26–20-27.
  24. ↑ Berkol et al. (2008), p. 20-36.
  25. ↑ Stull and Chines (2008), p. 6-87.
  26. ↑ Hall (2008), p. 5-110.
  27. ↑ Bush (2008), p. 20-39.
  28. ↑ Babrauskas (2008b), p. 6-105.
  29. ↑ Puchovsky and Hurley (2008), p. 3-172.
  30. ↑ Mowrer and Rosenbaum (2008), p. 3-187.
  31. ↑ Hurley and Bukowski (2008), p. 3-127.
  32. ↑ Ahrens et al. (2008), p. 3-70.
  33. ↑ Ahrens et al. (2008), pp. 3-89–3-90.
  34. ↑ Van Rossum (2027), §4.1.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Babrauskas, V. (2008b). Upholstered furniture and mattresses. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-103–6-128). National Fire Protection Association.
  • Berkol, A., Briese, B., & Comeau, E. (2008). Hotels and university housing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-23–20-36). National Fire Protection Association.
  • Bush, K. (2008). Apartment buildings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-37–20-47). National Fire Protection Association.
  • Gamache, S. (2008). Reaching high-risk groups. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-63–5-85). National Fire Protection Association.
  • Hall, J. R., Jr. (2008). Using data for public education planning and decision making. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-103–5-118). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Hirschler, M. M. (2008a). Concepts and protocols of fire testing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-35–6-60). National Fire Protection Association.
  • Hurley, M. J., & Bukowski, R. W. (2008). Fire hazard analysis techniques. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-121–3-134). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Lathrop, J. K. (2008b). One- and two-family dwellings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-55–20-61). National Fire Protection Association.
  • Mowrer, F. W., & Rosenbaum, E. R. (2008). Overview of performance-based fire protection design. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-183–3-194). National Fire Protection Association.
  • Ohlemiller, T. J. (2002). Smoldering combustion. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-200–2-210). National Fire Protection Association; Society of Fire Protection Engineers.
  • Puchovsky, M. T., & Hurley, M. J. (2008). Performance-Based codes and standards for fire safety. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-167–3-181). National Fire Protection Association.
  • Stull, J. O., & Chines, S. A. (2008). Fibers and textiles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-75–6-102). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.