Live fire training is fire service training in which trainees fight real, deliberately set fires under controlled conditions. It gives hands-on practice with actual fires, and at a training centre the "burn building" is the structure built for it.[1][2] Fires may be set in acquired structures, such as vacant houses, in purpose-built burn buildings fired with gas or ordinary combustibles, in exterior props, or as exterior flammable liquid fires.[3] Its value lies in realism: learning is more effective when it is relevant to the work, and realistic, intense experiences are remembered longer.[4] The same realism makes it dangerous. Several US training deaths followed a flashover or rapid fire spread in a building without an adequate water supply or escape routes.[5]

In the United States, NFPA 1403, Standard on Live Fire Training Evolutions, sets the rules for such exercises. It was first published in 1986, after training deaths that included two fire fighters in Boulder, Colorado, in 1982.[5] By 2008 several states, among them Washington and Florida, required live fire training to follow it.[6] Training centres, airport fire departments and industrial fire brigades use live fire training in different forms.[1][7] Environmental limits on smoke, runoff and fuel have also shaped how it is done.[8][9]

Purpose and value

Laughlin (2008) explains the appeal of live fire training through the "laws of learning". Under the law of relevance, learning is more effective when it is shown to be highly relevant to the learner's life and work. Realistic training has higher relevance, which makes it tempting to provide live fire training, but Laughlin adds that the overriding safety requirements should not be forgotten.[4] Under the law of emotional learning, learning that is accompanied by intense emotions tends to last longer. This fits realistic and even stressful training, but a scenario that becomes too intense can become dangerous and interfere with learning.[4]

Live fire exercises serve the job performance requirements of NFPA 1001, the US standard for fire fighter professional qualifications. Acomb and LeBoeuf (2008) call the burn building "vital" in teaching the skills that NFPA 1001 requires, especially those that need live fire training scenarios.[2] Drill towers, smoke rooms and live fire training structures are expensive to build properly, but Laughlin (2008) considers them important for training in basic firefighting and for building confidence.[10] He also notes that the value of realistic simulation brings an extra responsibility for safety.[10]

Realism matters outside municipal fire departments too. For industrial fire brigades, Snyder (2008) advises that firefighting training be made as realistic as possible and simulate the fire conditions actually expected. He warns that too many brigades rely on stereotyped training with outside oil-pit fires or scrap-wood fires, which seldom prepares them for typical interior fires.[1] Public fire department training grounds near a plant are useful because they are usually arranged for hands-on training with actual fires, and such training should comply with NFPA 1403.[1] At US airports, each aircraft rescue and firefighting fire fighter must take part in at least one live-fire drill. The drill simulates an aircraft fire of the size typical for the index of the airport's certificate.[7]

Fire behaviour in training

A training fire inside a structure is a compartment fire, and trainees must learn to recognise how it develops. NFPA 1403 calls for students in acquired structures to have prior training so that they understand the safety issues and can recognise normal and abnormal fire behaviour.[3] A key transition is flashover, in which surfaces exposed to thermal radiation reach their ignition temperature more or less simultaneously and fire spreads rapidly through the whole space.[11] Before flashover a fire is local and fuel-controlled; after it the whole room is burning and the fire is usually ventilation-controlled.[12]

The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².[13] Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.[12]

Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe layer burning as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.[14] A backdraft is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.[15]

Training centres can also demonstrate fire behaviour deliberately. A fire behaviour laboratory, also called a flashover simulator, consists of two shipping containers placed side by side and offset vertically to demonstrate fire behaviour.[16] Where real fire is not needed, a smokehouse provides simulated smoke conditions. In it, performance can be observed while real fires are avoided as a safety measure.[17]

Training environments

NFPA 1403 has separate chapters for four settings: acquired structures, gas-fired and non-gas-fired buildings at training centres, exterior props, and exterior Class B (flammable liquid) fires.[3] Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.[3] Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.[18]

At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.[2] Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.[19] Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.[2]

Some large centres chose gas. One of the main motivations for the design of the Tarrant County College Fire Service Training Center in Fort Worth, Texas, was live fire training without the safety risks of acquired structures. According to the college, it was one of the largest computer-controlled, gas-fired facilities in the world, with six separate live fire buildings.[10]

Exterior props are typically gas-fired, in most cases with LP gas, because natural gas flames are difficult to see in daylight. Vendors offer props that simulate car, fuel spill, tank, dumpster, railcar, aircraft and shipboard fires, among others.[8] Mobile gas-fired props bring live fire training to students in statewide and regional programmes, although a trailer cannot provide the proportions of a burn building.[8] Class A materials can also be burned outdoors, for example in a junked car. All closed containers, such as tanks, bumpers, pistons and shock absorbers, must first be removed to prevent bursting, and upholstery and plastics with hazardous emissions should also be removed.[8]

Burn building design

Acomb and LeBoeuf (2008) describe the burn building as usually the first training structure provided at a training centre.[2] It can deteriorate quickly if it is not designed correctly, and there are three main causes of damage. The first is heat, which can reach 2000 °F (1093 °C) where flames impinge directly, as on ceilings above training fires. The second is thermal shock when heated surfaces are sprayed with cold water. The third is abuse inherent in training, such as hose streams and impacts from tools and gear.[2]

No building material is immune to these conditions. Masonry cracks and gradually deteriorates, steel warps and corrodes, and concrete cracks and spalls.[2] The structural elements are therefore protected with thermal linings. For ceilings these are mostly proprietary products that differ in materials and installation, so they should be judged on initial and long-term cost, verifiable durability and insulating capability, and references.[2] Steel is not an insulator and tends to warp, and refractory (calcium aluminate) concrete should not be used for structural components because of its record of severe damage.[2] The two most common types of burn building are combinations of concrete and masonry and pre-engineered steel buildings.[20]

Details serve both training and safety. Possible features include various roof pitches and ventilation cutouts, durable doors and shutters that tolerate heat while keeping in smoke, drainage scuppers, forced-entry doors, standpipes and temperature monitoring systems.[21] The building is best accessible from all sides and lockable where the grounds are not fenced.[21] A burn building combined with a training tower saves site space, whereas separate structures allow live fire training and tower drills to run at the same time.[22]

Experience in designing schools or fire stations does not provide the expertise needed for live fire training structures. Architects and engineers without training centre experience should therefore team with specialist consultants.[23] The authors treat training centres together with fire station design, since needs assessment, master planning, site selection and design follow the same process for both.[16]

The building also needs a budget after it opens. The operations and maintenance budget includes training fuel and any abatement of noise, smoke and runoff. It also covers routine structural engineering evaluations of the burn building, as called for by NFPA 1403.[24] The design draws on several documents, including NFPA 1402, Guide to Building Fire Service Training Centers, NFPA 1403, and the gas codes NFPA 54 and NFPA 58.[25]

Safety rules and NFPA 1403

Laughlin (2008) reads the training injuries and deaths of the previous 25 years as a warning. Instructors can forget that a realistic scenario can have disastrous results when safety is not the paramount consideration.[5] Such training deaths and injuries form part of the wider record of firefighter injuries and fatalities. NFPA 1403 was developed after numerous training deaths, especially those of two fire fighters at Boulder in 1982 in an abandoned wood-frame building.[5] There, rapid fire spread across a combustible low-density fiberboard ceiling, an inadequate water supply, inadequate exits and a general lack of planning contributed to the deaths.[5] During its development, NFPA 1403 drew approximately 1,000 comments at the Report on Comments stage in 1985, and the first edition followed in 1986.[26][5]

The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.[5] In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.[3]

The exercise had designated safety officers and a rapid intervention team, but the fuel load contributed to a flashover only 3 minutes later.[3] Four instructors inside the building as interior safety officers escaped, but the lieutenant and the fire fighter in the exercise died of smoke inhalation and thermal injuries.[3] After a 19-year-old trainee died in New York in 2001, the officer supervising the exercise was convicted of criminally negligent homicide. The state then offered two programmes on live fire training safety, both referring to NFPA 1403.[3]

NFPA 1403 calls the ongoing training of fire fighters "the cornerstone of good fire protection in today's world". It adds that the benefits of live fire training "can be negated by the injuries and deaths suffered by fire fighters under unsafe and poorly supervised training conditions".[3] A US Nuclear Regulatory Commission report listed the 2002 edition of NFPA 1403 as current in 2004.[27]

In acquired structures, the building must be specially prepared to minimise the factors that contribute to uncontrolled burning, and fuel loads are limited. Before any training fire, participants must become familiar with the building, its exits and the plan for the exercise.[3] Adequate water supplies and enough instructors to supervise the burn must be available, and flammable or combustible liquids may not be used to fuel the fire.[3] The standard also requires accurate and complete training records.[3]

Environmental constraints

Live fire training produces smoke, light, noise and contaminated water, and these affect where and how it can be done. Visible flames, night lighting, noise and smoke have a negative impact on neighbours. Acomb and LeBoeuf (2008) therefore recommend adequate setback and visual buffering with berms, vegetation, fences and buildings.[28] When potential sites are compared, the smoke plume and prevailing winds should be evaluated. Runoff can carry soot, unburned Class A or Class B fuels and firefighting chemicals.[25]

Flammable liquid pits were becoming less common because of concerns about groundwater contamination and black smoke.[8] At airports, Boucher (2008) reports that live fire training with hydrocarbon fuels and other flammable liquids had been suspended at many airports because of local environmental constraints. The Federal Aviation Administration, the US military and private industry were developing alternative exercises that duplicate realistic fuel fire atmospheres while meeting environmental requirements.[9]

Firefighting foam adds its own problems. Scheffey (2008) lists firefighting training evolutions among the discharge scenarios to consider when assessing the environmental impact of foam. Training offers greater opportunities than real incidents to control foam flow, particularly by collecting it.[29] New techniques with simulated pool fires and simulated foams were available.[30] In uncontrolled fires, spills and live fire training scenarios, foams may contain suspended fuels that become emulsified in the foam-water solution.[31]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 Snyder (2008), p. 12-194.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Acomb and LeBoeuf (2008), p. 12-247.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 Laughlin (2008), p. 12-173.
  4. ↑ 4.0 4.1 4.2 Laughlin (2008), p. 12-165.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 Laughlin (2008), p. 12-172.
  6. ↑ Laughlin (2008), p. 12-163.
  7. ↑ 7.0 7.1 Kreckie (2008), p. 13-107.
  8. ↑ 8.0 8.1 8.2 8.3 8.4 Acomb and LeBoeuf (2008), p. 12-250.
  9. ↑ 9.0 9.1 Boucher (2008), p. 21-144.
  10. ↑ 10.0 10.1 10.2 Laughlin (2008), p. 12-168.
  11. ↑ Janssens (2008), p. 2-61.
  12. ↑ 12.0 12.1 Van Rossum (2027), §4.7.
  13. ↑ Custer (2008), p. 2-56.
  14. ↑ Gottuk and Lattimer (2002), p. 2-55.
  15. ↑ Van Rossum (2027), §4.9.
  16. ↑ 16.0 16.1 Acomb and LeBoeuf (2008), p. 12-251.
  17. ↑ Nolan (2000), as cited in Iqbal and Salley (2004), p. F-54.
  18. ↑ Corbett (2008), p. 12-130.
  19. ↑ Conroy (2008), p. 17-71.
  20. ↑ Acomb and LeBoeuf (2008), pp. 12-247–12-248.
  21. ↑ 21.0 21.1 Acomb and LeBoeuf (2008), p. 12-248.
  22. ↑ Acomb and LeBoeuf (2008), p. 12-249.
  23. ↑ Acomb and LeBoeuf (2008), p. 12-241.
  24. ↑ Acomb and LeBoeuf (2008), p. 12-246.
  25. ↑ 25.0 25.1 Acomb and LeBoeuf (2008), p. 12-245.
  26. ↑ Loflin (2008), p. 12-109.
  27. ↑ Iqbal and Salley (2004), p. E-11.
  28. ↑ Acomb and LeBoeuf (2008), p. 12-244.
  29. ↑ Scheffey (2008), p. 17-68.
  30. ↑ Scheffey (2008), p. 17-69.
  31. ↑ Scheffey (2002), p. 4-119.

References

  • Acomb, D. J., & LeBoeuf, R. M. (2008). Fire rescue stations and fire service training centers. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-233–12-251). National Fire Protection Association.
  • Boucher, B. (2008). Aviation. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-135–21-149). National Fire Protection Association.
  • Conroy, M. T. (2008). Fire extinguisher use and maintenance. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-71–17-92). National Fire Protection Association.
  • Corbett, G. P. (2008). Effect of building construction and fire protection systems on fire fighter safety. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-127–12-141). National Fire Protection Association.
  • Custer, R. L. P. (2008). Dynamics of compartment fire growth. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-49–2-58). National Fire Protection Association.
  • Gottuk, D. T., & Lattimer, B. Y. (2002). Effect of combustion conditions on species production. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-54–2-82). National Fire Protection Association; Society of Fire Protection Engineers.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Janssens, M. L. (2008). Basics of fire containment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-59–2-74). National Fire Protection Association.
  • Kreckie, J. (2008). Aircraft rescue and fire fighting (ARFF). In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-99–13-115). National Fire Protection Association.
  • Laughlin, J. W. (2008). Training programs for fire and emergency service personnel. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-161–12-175). National Fire Protection Association.
  • Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
  • Scheffey, J. L. (2002). Foam agents and AFFF system design considerations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 4-88–4-122). National Fire Protection Association; Society of Fire Protection Engineers.
  • Scheffey, J. L. (2008). Foam extinguishing agents and systems. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-45–17-70). National Fire Protection Association.
  • Snyder, M. (2008). Industrial fire loss prevention. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-177–12-198). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.