  1. 1Definition and classification
  2. 2How the reaction creates a fire hazard
  3. 3Main groups of water-reactive materials
  4. 4Storage and handling
  5. 5Fire fighting and extinguishing agents
  6. 6Worked example: gas release at the Division 4.3 threshold
  7. 7Limits and common misconceptions
  8. 8See also
  9. 9Notes
  10. 10References

A water-reactive material is a chemical that reacts with water, often violently, and in doing so releases heat, a flammable or toxic gas, or both.[1][2] If the material is combustible, the heat of the reaction can ignite the material itself; if it is noncombustible, the heat can still ignite combustible materials nearby.[1] Typical examples are the alkali metals sodium, potassium and lithium, carbides that give off acetylene, metal hydrides that give off hydrogen, acid anhydrides, quicklime and some inorganic peroxides.[1][3][4] The hazard matters most in fire fighting, because water is normally used on fires involving chemicals, except on chemicals that are dangerously water-reactive.[5] In the United States, as described in the 2008 edition of the Fire Protection Handbook, they carry a "W" on the NFPA 704 diamond and travel as Division 4.3 "dangerous when wet" materials.[6][7] They are stored dry, in waterproof and airtight containers, and fires in them are fought with special dry powders, dry sand or inert gases rather than water.[1][8]

Definition and classification

In the handbook chapter on the storage and handling of chemicals, Davenport (2008) treats water-reactive and air-reactive chemicals as one group, because both liberate significant quantities of heat when they react.[1] He names anhydrides, carbides, hydrides and the alkali metals lithium, sodium and potassium as the typical water-reactive chemicals.[1] In the SFPE Handbook, Fleming (2002) calls water the most commonly used extinguishing agent, but considers it inappropriate for certain water reactive materials, because its use can produce heat, flammable or toxic gases, or explosions.[9] Frank (2008) states the same general rule for materials that react with water and may release oxygen, flammable gases and heat, and lists alkalies, anhydrides, carbides, hydrides, nitrates and peroxides as examples.[2]

Transport rules give the term a numerical boundary. In the international hazard classes reproduced by C. J. Wright (2008a), water-reactive solids and liquids belong to Class 4, "flammable solids and reactive liquids and solids", as Division 4.3, with calcium carbide and potassium as examples.[7] There, a dangerous-when-wet material is one that, by contact with water, is liable to become spontaneously flammable or to give off flammable or toxic gas at more than 1 L per kilogram per hour.[10] Shipping papers can carry a "DANGEROUS WHEN WET" notation.[11] NUREG-1805 lists the same Division 4.3 in its table of United States Department of Transportation hazard classes.[12]

The NFPA 704 diamond, as shown by C. J. Wright (2008a) from the 2007 edition of the standard, has four colour-coded quadrants.[6] Blue on the left stands for health, red at the top for flammability and yellow on the right for reactivity.[6] The bottom quadrant carries special information, such as "OX" for oxidisers or a "W" crossed by a horizontal line for water-reactive materials.[6] The numbers in the quadrants run from 0 for a low hazard to 4 for a high hazard.[6]

United States workplace regulation (OSHA, 29 CFR 1910) names water-reactives among its examples of a "physical hazard", together with pyrophorics and unstable (reactive) chemicals.[13] Under the United States Environmental Protection Agency rules summarised by Severson (2008), a waste is reactive if, among other criteria, it reacts violently with water or forms potentially explosive mixtures with it.[14] A waste that gives off toxic gases, vapours or fumes in dangerous quantities when mixed with water is also reactive.[14]

How the reaction creates a fire hazard

The first hazard is heat. Calcium oxide, better known as quicklime, reacts vigorously with water and can release enough heat to ignite paper, wood or other combustible material under some conditions.[3] Dry solid caustic soda and caustic potash are noncombustible, but their heat of solution in water can also be sufficient to ignite combustible material.[1] Sodium, potassium and strontium peroxides react vigorously with water and release oxygen as well as large amounts of heat.[4] The heat from reaction with just a little water might decompose the contents of an entire container, and a fire is likely if organic material is present.[4]

The second hazard is a flammable gas. A number of metals and the metal hydrides release hydrogen, and carbides such as calcium carbide release acetylene.[15] Hydrogen burns in air between 4.0 and 75.0% by volume, has a specific gravity of 0.07 relative to air and an ignition temperature of 500 °C (932 °F).[16] Acetylene burns between 2.5 and 81.0% and ignites at 305 °C (581 °F).[16] Hydrogen released at low pressure is unlikely to ignite by itself, but it can cause combustion explosions with very rapid pressure rises that are extremely difficult to vent.[17] Heat and gas can also act together: when one-third of its weight of water is added to a water-reactive carbide, the temperature can rise far enough to ignite the gas that is generated.[3]

Other products are toxic. Cyanide salts react with acidified water to form highly toxic hydrogen cyanide, and phosphorus pentasulfide reacts with water to give hydrogen sulfide, a very toxic gas.[15][18] A further danger is physical: violent steam explosions can result when water enters molten metal.[15]

Zalosh (2008) lists the hydration of water-reactive materials among the chemical reactions that can cause explosions.[19] Such reactions can produce gas that overpressurises a vessel without adequate relief vent area, or run away and rapidly raise the pressure of the gases already present.[19] One example in his table occurred at South Baltimore, Maryland, on 13 October 1998.[19] There, an excessive rate of steam addition to powdered aluminium, aluminium chloride and water caused an uncontrolled reaction and five injuries.[19]

Main groups of water-reactive materials

The alkali metals (caesium, francium, lithium, potassium, rubidium, sodium and alloys such as NaK) are water reactive and generate hydrogen on contact with water.[20] Lithium, sodium, potassium and NaK react with water at room temperature, and the amount of metal or its particle size does not contribute to the risk of ignition.[20] Sodium floats on water, with a density of 0.97, and reacts vigorously and melts; the heat of the reaction may ignite the hydrogen released.[21] Potassium is usually more reactive than sodium, and the sodium-potassium alloys known as NaK react more vigorously than either metal, with leaks under pressure having ignited spontaneously.[21] Lithium also forms hydrogen, but its reaction does not generate enough heat to ignite the gas, so hydrogen can build up into an explosive cloud unless the area is well ventilated.[21]

Other metals react with water under some conditions. Magnesium, a combustible metal, combines so readily with oxygen that water applied to a magnesium fire can be decomposed, after which the released hydrogen burns and adds to the intensity of the fire.[22] The combustion of zirconium dust in air is stimulated by 5 to 10% of water, and some water-moistened metal powders such as zirconium burn with near-explosive violence.[8][23] Yet zirconium powder, being highly combustible, is customarily stored and shipped in 3.8 L (1 gal) containers with at least 25% water by volume, and completely immersed powder is difficult to ignite.[8] Damp hafnium powder releases hydrogen, but at ordinary temperatures not vigorously enough to ignite it.[8] In titanium melting furnaces, a penetrated water-cooled crucible lets water react explosively with the molten metal.[24]

Carbides and hydrides form the next groups. The carbides of sodium and potassium can react explosively with water, while calcium, lithium, potassium and barium carbides decompose in water to form acetylene; the carbides of silicon and tungsten, by contrast, are very stable.[1][3] The same reaction is used on purpose in acetylene generators, which react calcium carbide with water at the consuming site.[25] Metal hydrides react with water to form hydrogen.[3] Sodium hydride ignites with explosive violence on contact with water and may ignite by absorbing moisture from the air, and lithium hydride dust is likely to explode in humid air.[3]

Acid anhydrides are acids from which water has been removed, and they react with water, usually violently, to regenerate the acid.[1] The organic anhydrides are combustible and have lower flash points than their acids, for example 54 °C (129 °F) for acetic anhydride.[1] Sodium oxide reacts violently with water, and the heat of quicklime has already been described.[3] Some materials react with both water and air: triethylaluminium, the most common aluminium alkyl, ignites spontaneously in air and on contact with water, and sodium hydrosulfite heats spontaneously on contact with moisture and air.[1][3] Fluorine reacts explosively even with water vapour.[26]

Storage and handling

Water-reactive chemicals should be stored in dry areas, in waterproof and airtight containers kept off the floor on skids, in a storage area without combustible material or incompatible chemicals.[1] Materials that react with both water and air, such as the aluminium alkyls, are stored under inert liquids or inert gas.[1] Segregation from other materials, from processing operations and from incompatible materials is the first principle of chemical storage, and the possible rupture of vessels and mixing of incompatible materials under fire conditions must be considered.[5] NFPA 491, a guide to chemical incompatibility, describes more than 3400 dangerous reactions, and safe transport excludes chemicals that can react dangerously with each other from the same outside container.[27] The shipping label classifies a chemical for transport purposes only, so storage should be arranged from a thorough knowledge of its fire, health and reactivity hazards.[28]

The alkali metals show how these principles are applied. Drums and cases are kept in a dry, fire-resistant room or building used only for alkali metal storage, and because sprinkler protection would be undesirable there, no combustible materials are stored in the same area.[21] Where exposure fires could endanger equipment containing alkali metals, sprinklers may be considered, and NFPA 484 permits them for lithium storage.[21] The room should have no water or steam pipes, enough heat to prevent condensation, and ventilation at a high point to remove any hydrogen released by accidental contact with moisture.[21] Large quantities are often stored outdoors in aboveground tanks with a nitrogen atmosphere, or argon or helium in the case of lithium, and on workbenches the metal is kept under kerosene or oil.[21] Because hydrogen may be present, containers should not be opened by hammering on the lid.[21]

Slye (2008) calls it poor practice to place tanks of heat-reactive and water-reactive flammable liquids next to each other.[29] In a ground fire, water applied to protect the heat-reactive tank might penetrate the other tank and cause a violent reaction.[29] In laboratories, Anderson (2008a) judges the reaction of water with water-reactive chemicals, even sodium, during a flammable liquid fire in a fume hood too small to rule out water.[30] Where water-reactive materials are used in a hood, however, special precautions against an inadvertent discharge are needed.[30] At pesticide stores, contaminated runoff and the water reactivity of some materials, such as fumigants, argue against water.[31] Operators may then consider posting the NFPA 704 W signal to warn responders not to use water, after consulting the local authorities and insurers.[31]

Fire fighting and extinguishing agents

Water is the most commonly used extinguishing agent, mainly because it is widely available and inexpensive.[9] It also absorbs much heat: one US gallon takes up 2586.5 kJ when heated from 21 °C to steam at 100 °C, about 683 kJ per litre.[9] For water-reactive materials the quantity of water decides the outcome, since application of sufficient water can overcome the reaction of minor amounts of these materials.[9] Frank (2008) describes a range from minor to explosive reactions between water and combustible metals and advises, as a rule, against water on fires of magnesium, titanium, metallic sodium and hafnium.[2] Water can still be used to cool and protect exposures.[2] Large quantities of water have extinguished small quantities of burning magnesium where no pools of molten metal were present.[15]

Metal fires form their own class in the classification of fires used for portable extinguishers.[32] Class D fires involve combustible metals such as magnesium, titanium, zirconium, sodium, lithium and potassium, and require special agents known as dry powder.[32] Because the metals differ, even a Class D agent may be hazardous on the wrong metal.[33] In the United States practice described by Conroy (2008), the maximum travel distance to a Class D extinguisher is 22.9 m (75 ft).[33]

Water, foam and vaporising liquids should never be used on alkali metal fires.[8] Graphite-based powders, dry sand, dry sodium chloride, dry lithium chloride and dry soda ash blanket the fire while the metal cools below its ignition temperature.[8] Nitrogen blanketing works for sodium, potassium and NaK, but not for lithium, which can burn in nitrogen and needs argon or helium instead.[21][8] More generally, certain metals react exothermically with nitrogen, which leaves helium and argon as the only acceptable inert gases for them.[15]

Chemical fires need agent choices of their own. Fires involving hydrides can be smothered with a graphite-based powder or with dry, finely divided dolomite.[3][34] A hydride fire in an enclosed space should not be put out, because hydrogen keeps evolving after extinguishment and creates an explosion hazard.[34] Fires of aluminium alkyls, which react with both air and water, can be contained by dry chemical while the material burns out under control.[34]

Foam and wetting agents do not remove the problem. One condition for a foam to be fully effective is that the burning liquid is not water reactive.[35] Medium- and high-expansion foams should not be used on water-reactive metals or on materials such as triethylaluminium and phosphorus pentoxide unless tests show them to be acceptable.[36] Wet water, which is water with a wetting agent, has the same limitations as plain water on chemicals that react with water.[37]

These limits shape hazardous materials response. Manual fire fighting at stores of reactive chemicals may be severely limited by toxicity, smoke or the risk of explosion, and where explosion is possible it should be conducted from a remote location.[5] Christman (2008) stresses prefire planning, so that fire departments know before arrival which combustible metals are present at the businesses they protect.[38] In terms of the fire triangle of fuel, oxygen and temperature, water applied to a burning combustible metal is broken down into hydrogen and oxygen that feed the fire, while the reaction itself adds heat.[39][38]

Worked example: gas release at the Division 4.3 threshold

The Division 4.3 boundary of 1 L of gas per kilogram per hour allows a rough estimate of how fast a flammable atmosphere could form if wetted material stands in a closed room.[10] The estimate assumes that the gas is hydrogen, that it mixes evenly through the room volume, and that there is no ventilation or leakage. The time to reach the lower flammable limit is then the gas volume needed for that limit divided by the release rate:

t=xLFLVrm

Symbol Description Unit
t Time until the room reaches the lower flammable limit h
xLFL Lower flammable limit of the gas, as a volume fraction –
V Free volume of the room m³
r Gas release rate per kilogram of material m³/(kg·h)
m Mass of wetted material kg

Consider 200 kg of a material that, once wet, gives off hydrogen at exactly the threshold rate of 1 L/(kg·h), stored in a closed room of 50 m³. The release rate is 200 L/h, or 0.20 m³/h. With a lower flammable limit of 4.0% for hydrogen, the room needs 0.040 × 50 = 2.0 m³ of hydrogen to become flammable throughout, which takes 2.0 / 0.20 = 10 h.[16] Hydrogen is much lighter than air, with a specific gravity of 0.07, and the handbook recommends ventilation at a high spot in alkali metal storage rooms to remove it.[16][21] If the gas stayed in the top 0.5 m of a room 2.5 m high, only one-fifth of the volume would have to reach 4.0%, and the time would fall to about 2.0 h. A material releasing gas ten times faster would make the whole room flammable in about 1.0 h.

The example shows the order of magnitude only. Real releases can be far faster, as with sodium hydride, which ignites with explosive violence on contact with water, and the result scales directly with the mass and the gas release rate.[3] For a design or an emergency plan, the material's own data are needed. Under United States law, manufacturers must issue a material safety data sheet (MSDS) that gives its reactivity and stability.[40]

Limits and common misconceptions

A frequent misconception is that all water-reactive materials react alike. The alkali metals themselves differ widely: the heat of the sodium-water reaction can ignite the hydrogen it releases, whereas the lithium-water reaction does not, which allows unburned hydrogen to accumulate instead.[21] A second misconception is that a small amount of water is always safer than a large one. With sodium and potassium peroxides, a little water can decompose a whole container, and burning lithium aluminium hydride solutions in ether burn more intensely when small amounts of water are added.[4][3] Conversely, large quantities of water can overcome the reaction of minor amounts of material.[9]

Water-reactivity also does not rule out sprinklers in every case. For magnesium, automatic sprinklers are considered desirable because they give automatic notification and control of the fire.[22][24] Their water may at first intensify the magnesium fire, but it protects the structure and prevents ignition of surrounding combustibles.[24] Noncombustible materials are not harmless either: peroxides, quicklime and caustics do not burn, yet their reaction with water can start a fire in nearby combustibles.[4][3][1]

The classifications described here are those of the United States and of the international transport classes, as presented in the 2008 edition of the Fire Protection Handbook.[7] Its description of the NFPA 704 marking follows the 2001 and 2007 editions of the standard.[6] The Division 4.3 rate of 1 L/(kg·h) is a boundary for transport classification.[10] A transport label classifies a chemical for transport purposes only, so storage has to be based on its full fire, health and reactivity hazards.[28] Caustics, for example, appear in the handbook both as water- and air-reactive chemicals and as corrosives, which shows that one label rarely describes all the hazards of a chemical.[34]

See also

Notes

  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 Davenport (2008), p. 7-50.
  2. ↑ 2.0 2.1 2.2 2.3 Frank (2008), p. 17-41.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 Davenport (2008), p. 7-51.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 Davenport (2008), p. 7-46.
  5. ↑ 5.0 5.1 5.2 Davenport (2008), p. 7-44.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 6.5 C. J. Wright (2008a), p. 13-123.
  7. ↑ 7.0 7.1 7.2 C. J. Wright (2008a), p. 13-119.
  8. ↑ 8.0 8.1 8.2 8.3 8.4 8.5 8.6 Christman (2008), p. 6-160.
  9. ↑ 9.0 9.1 9.2 9.3 9.4 Fleming (2002), p. 4-72.
  10. ↑ 10.0 10.1 10.2 C. J. Wright (2008a), p. 13-120.
  11. ↑ C. J. Wright (2008a), p. 13-126.
  12. ↑ Iqbal and Salley (2004), p. B-22.
  13. ↑ Hildebrand and Noll (2008), p. 13-82.
  14. ↑ 14.0 14.1 Severson (2008), pp. 7-60–7-61.
  15. ↑ 15.0 15.1 15.2 15.3 15.4 Yu and Newman (2008), p. 2-91.
  16. ↑ 16.0 16.1 16.2 16.3 Lemoff (2008), p. 6-174.
  17. ↑ Lemoff (2008), p. 6-181.
  18. ↑ Davenport (2008), p. 7-48.
  19. ↑ 19.0 19.1 19.2 19.3 Zalosh (2008), p. 2-102.
  20. ↑ 20.0 20.1 Christman (2008), p. 6-153.
  21. ↑ 21.00 21.01 21.02 21.03 21.04 21.05 21.06 21.07 21.08 21.09 21.10 Christman (2008), p. 6-159.
  22. ↑ 22.0 22.1 Christman (2008), p. 6-157.
  23. ↑ Christman (2008), p. 6-154.
  24. ↑ 24.0 24.1 24.2 Christman (2008), p. 6-158.
  25. ↑ Lemoff (2008), p. 6-177.
  26. ↑ Davenport (2008), p. 7-53.
  27. ↑ Davenport (2008), p. 7-54.
  28. ↑ 28.0 28.1 Davenport (2008), p. 7-45.
  29. ↑ 29.0 29.1 Slye (2008), p. 6-198.
  30. ↑ 30.0 30.1 Anderson (2008a), p. 9-160.
  31. ↑ 31.0 31.1 Whitford (2008), p. 6-242.
  32. ↑ 32.0 32.1 Conroy (2008), pp. 17-71–17-72.
  33. ↑ 33.0 33.1 Conroy (2008), p. 17-87.
  34. ↑ 34.0 34.1 34.2 34.3 Davenport (2008), p. 7-52.
  35. ↑ Scheffey (2008), p. 17-46.
  36. ↑ Scheffey and Hickey (2002), p. 4-129.
  37. ↑ Frank (2008), p. 17-36.
  38. ↑ 38.0 38.1 Christman (2008), p. 6-155.
  39. ↑ Van Rossum (2027), §4.2.
  40. ↑ Davenport (2008), pp. 7-43–7-44.

References

  • Anderson, R. R. (2008a). Fire protection of laboratories using chemicals. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 9-157–9-166). National Fire Protection Association.
  • Christman, T. (2008). Metals. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-153–6-164). National Fire Protection Association.
  • Conroy, M. T. (2008). Fire extinguisher use and maintenance. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-71–17-92). National Fire Protection Association.
  • Davenport, J. A. (2008). Storage and handling of chemicals. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 7-43–7-55). National Fire Protection Association.
  • Fleming, R. P. (2002). Automatic sprinkler system calculations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 4-72–4-87). National Fire Protection Association; Society of Fire Protection Engineers.
  • Frank, J. A. (2008). Characteristics and hazards of water and water additives for fire suppression. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-31–17-43). National Fire Protection Association.
  • Hildebrand, M. S., & Noll, G. G. (2008). Public fire protection and hazmat management. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-81–13-98). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Lemoff, T. C. (2008). Gases. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-165–6-186). National Fire Protection Association.
  • Scheffey, J. L. (2008). Foam extinguishing agents and systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-45–17-70). National Fire Protection Association.
  • Scheffey, J. L., & Hickey, H. E. (2002). Foam system calculations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 4-123–4-148). National Fire Protection Association; Society of Fire Protection Engineers.
  • Severson, P. R. (2008). Hazardous waste control. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 7-57–7-69). National Fire Protection Association.
  • Slye, O. M., Jr. (2008). Flammable and combustible liquids. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-197–6-208). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.
  • Whitford, F. (2008). Pesticides in the workplace. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-233–6-245). National Fire Protection Association.
  • Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-117–13-144). National Fire Protection Association.
  • Yu, H.-Z., & Newman, J. S. (2008). Theory of fire extinguishment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-79–2-92). National Fire Protection Association.
  • Zalosh, R. (2008). Explosions. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-93–2-106). National Fire Protection Association.