Summary

Flow through a doorway against effective width in C/VM2, with the cap of 50 persons per minute for a self-closing door leaf. Based on Ministry of Business, Innovation and Employment (2025b), pp. 33–34.

Original vector illustration for Exit capacity, level 2 Intermediate.

  • Source basis: Ministry of Business, Innovation and Employment (2025b), p. 33 (Equation 3.5, D = 1.9 persons/m², k = 1.4) and p. 34 (cap and its explanation)
  • Alt text: Line chart: door flow rising linearly with effective width, about 79 persons per minute per metre, with a horizontal cap at 50 persons per minute.