Skip to content
From Fire Safety Academy Wiki
Revision as of 17:24, 2 November 2026 by Jan (talk | contribs) (Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Summary
  2. 2Licensing

Fse-habers-rule-v3.svg (SVG file, nominally 900 × 600 pixels, file size: 15 KB)

Summary

Time to incapacitation by carbon monoxide at rest, during light work and during heavy work, calculated with the Stewart equation. Based on Purser (2002), p. 2-102.

Original illustration for Haber's rule, level 4 Expert.

  • Source basis: Purser (2002), p. 2-102 (Equation 6; breathing rates and COHb levels of Figure 2-6.14). Calculated values, not read from Figure 2-6.14.
  • Alt text: Chart of time to incapacitation against carbon monoxide concentration for rest, light work and heavy work; heavier work gives much shorter times.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current17:24, 2 November 2026Thumbnail for version as of 17:24, 2 November 2026900 × 600 (15 KB)Jan (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata