Skip to content
From Fire Safety Academy Wiki
Revision as of 17:16, 2 November 2026 by Emma (talk | contribs) (Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Summary
  2. 2Licensing

Fse-vapour-cloud-explosion-v1.svg (SVG file, nominally 900 × 600 pixels, file size: 7 KB)

Summary

Immediate and delayed ignition require different exposure scenarios. Based on Electric Power Research Institute and U.S. Nuclear Regulatory Commission (2005), pp. N-7–N-9.

Original illustration for Vapour cloud explosion, level 3 Advanced.

  • Source basis: Electric Power Research Institute and U.S. Nuclear Regulatory Commission (2005), pp. N-7–N-9.
  • Alt text: A release branches into immediate jet combustion or a dispersed cloud that ignites later.
  • Accuracy notes: No event probabilities; no guaranteed explosion for every delayed ignition.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current17:16, 2 November 2026Thumbnail for version as of 17:16, 2 November 2026900 × 600 (7 KB)Emma (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity