Contents
Fse-minimum-ignition-energy-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 8 KB)
Summary
The same powder sample has distinct energy, cloud-temperature and layer-temperature results. Based on Zalosh (2002), pp. 3-404–3-405.
Original illustration for Minimum ignition energy, level 3 Advanced.
- Source basis: Zalosh (2002), pp.3-404–3-405, Table3-16.2; redraw conceptual apparatus, not a test specification; redraw, do not copy.
- Alt text: Three test concepts distinguish the milk-powder sample’s spark energy, cloud ignition temperature and layer ignition temperature.
- Accuracy notes: Use spaced final labels; keep units distinct and do not imply conversion between millijoules and degrees Celsius.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:15, 2 November 2026 | 900 × 600 (8 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: