Contents
Fse-sandwich-panel-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 8 KB)
Summary
Steady-state temperature profile through the insulated steel roof of the worked example (400 °C smoke, 10 °C outside). Based on Van Rossum (2027), §5.2 and §5.5.
Original vector illustration for Sandwich panel, level 2 Intermediate.
- Source basis: Van Rossum (2027), §5.2 (series resistance method, temperature drop per layer, roof example) and §5.5 (property table); Beyler and Hirschler (2002), p. 1-128
- Alt text: Line chart of temperature through the roof panel: about 395 °C at the hot face of the core, falling almost linearly to about 15 °C at the cool face.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:13, 2 November 2026 | 900 × 600 (8 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: