Summary

Steady-state temperature profile through the insulated steel roof of the worked example (400 °C smoke, 10 °C outside). Based on Van Rossum (2027), §5.2 and §5.5.

Original vector illustration for Sandwich panel, level 2 Intermediate.

  • Source basis: Van Rossum (2027), §5.2 (series resistance method, temperature drop per layer, roof example) and §5.5 (property table); Beyler and Hirschler (2002), p. 1-128
  • Alt text: Line chart of temperature through the roof panel: about 395 °C at the hot face of the core, falling almost linearly to about 15 °C at the cool face.