Skip to content
From Fire Safety Academy Wiki
Revision as of 16:52, 2 November 2026 by Lisa (talk | contribs) (Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Summary
  2. 2Licensing

Fse-diffusion-flame-v3.svg (SVG file, nominally 900 × 600 pixels, file size: 14 KB)

Summary

Mean flame height from the Heskestad correlation for three fire diameters; the dot marks the pallet stack example (2,600 kW, 1.21 m, 4.2 m). Based on Heskestad (2002), pp. 2-3 to 2-4.

Original vector illustration for Diffusion flame, level 2 Intermediate.

  • Source basis: Heskestad (2002), p. 2-3 (correlation, validity, negative heights unphysical) and p. 2-4 (pallet stack example)
  • Alt text: Line chart: mean flame height rising with heat release rate from 0 to 5,000 kW, for fire diameters 0.5 m, 1.21 m and 2.0 m.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current16:52, 2 November 2026Thumbnail for version as of 16:52, 2 November 2026900 × 600 (14 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata