Contents
Fse-hydraulic-evacuation-model-v2.svg (SVG file, nominally 900 × 600 pixels, file size: 7 KB)
Summary
Demand above downstream capacity accumulates upstream, while merge priority remains a separate assumption. Based on Nelson and Mowrer (2002), p. 3-372.
Original illustration for Hydraulic evacuation model, level 3 Advanced.
- Source basis: Nelson and Mowrer (2002), p. 3-372. Create an original visual; redraw, do not copy source figures.
- Alt text: Two occupant streams merge before a bottleneck, where excess arrivals form a queue.
- Accuracy notes: Add total flows, not specific flows without width. Do not assign equal priority as a physical law.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 16:45, 2 November 2026 | 900 × 600 (7 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: