Summary

Air handling in a semiconductor cleanroom. Most of the air is recirculated; a slight overpressure keeps leakage flowing outwards. Based on DeGiorgio and Peterkin (2008), pp. 9-125–9-126.

Original illustration for Semiconductor fabrication facility.

  • Alt text: Cross-section of a cleanroom with HEPA ceiling, downward airflow, perforated raised floor, return plenum and recirculation fan