Summary

Average heat release rate of a burning creosote deposit against burn-off time, from Q = E/t; the dashed curve is illustrative and assumes the same deposit composition and density with energy scaled by layer thickness. Based on Gore Willse (2008a), pp. 10-53 and 10-55, and Van Rossum (2027), §4.5.

Original illustration for Chimney fire.

  • Alt text: Line chart of average heat release rate against burn-off time for 128 MJ and 512 MJ creosote deposits, falling from several hundred kW at 5 minutes