Summary

Key temperatures for bridge steel in fire: stiffness and strength loss, critical temperatures for structural, reinforcing and prestressing steel, and the UL 1709 hydrocarbon test temperature. Based on Pessiki (2008), p. 19-71; Kodur and Harmathy (2002), p. 1-163; Janssens (2008), p. 2-67.

Original illustration for Bridge fire.

  • Alt text: Temperature scale marking steel stiffness loss at 316 °C, strength loss at 538 °C, prestressing steel 426 °C and the UL 1709 furnace at 1093 °C