Skip to content
From Fire Safety Academy Wiki
Revision as of 13:00, 12 November 2026 by Peter (talk | contribs) (Add SVG figures fse-candle-fire-v1.svg, fse-candle-fire-v2.svg, fse-candle-fire-v3.svg, fse-candle-fire-v4.svg (list-3 visual plan))
Contents
  1. 1Definition and classification
  2. 2Scale of the problem
  3. 3How a candle flame works
  4. 4Heat output and ignition potential
  5. 5Prevention and education
  6. 6Candles in non-residential buildings
  7. 7Limits of the data and common misconceptions
  8. 8See also
  9. 9Notes
  10. 10References

A candle fire is a fire in which the heat that ignited the first material came from a burning candle.[1] In US fire statistics, "candle" is one of the heat-source categories of the National Fire Incident Reporting System, next to smoking materials and other open flames.[2] A candle is a small, steady flame of about 50 to 80 W, but it can burn for hours and can ignite bedding, furniture or other items placed too close to it.[3][4][5][6] In the United States in 1999–2002, candles started about 18,200 reported home structure fires a year, which killed 160 people, injured 1,640 and caused 392 million dollars of direct damage.[7]

The share of US home fires started by candles rose from 1 percent in the early 1980s to 5 percent in 2001 and 2002.[8] Compared with other leading causes, candle fires injure many people and cause large losses per fire.[7][9] Prevention relies mainly on education, such as keeping candles at least 305 mm (12 in.) from anything that can burn, and on rules for candles in lodging, assembly and religious buildings.[5][10] A candle used to test for air leaks started the 1975 cable fire at the Browns Ferry nuclear power plant, one of the most serious events at a US commercial nuclear plant.[11][12]

Definition and classification

In the US National Fire Incident Reporting System (NFIRS), each fire is described by several cause-related data elements, including the heat source, the item first ignited and the factors that contributed to ignition.[13] "Candle" is a heat source, so a candle fire is defined by the ignition source and not by the material that burned.[1] In 1999–2002, candles were the heat source in 5 percent of US home structure fires.[2] The NFPA adds to this category a proportional share of fires coded only as "heat from an unclassified open flame or smoking material".[1]

Because the categories come from different data elements, one fire can appear under several headings. A candle that ignites a sofa counts as a candle fire by heat source and as an upholstered furniture fire by item first ignited.[14] Most fires classed as "playing with fire" involve matches or lighters, but candles may also be involved.[15] The fire cause of a candle fire can therefore be described by the candle, by the item it ignited or by the behaviour that brought them together. When interior finish is the first item ignited, typical heat sources include open flames such as matches, lighters and candles.[16]

Scale of the problem

In US fire statistics for all structure fires in 1999–2002, candles caused 20,900 fires a year (4 percent) and 170 civilian deaths (5 percent). They also caused 1,750 injuries (10 percent) and 468 million dollars of direct damage (5 percent); the estimates exclude 11 September 2001.[1] Homes accounted for about 87 percent of these fires and 94 percent of the deaths.[1][7] Candle fires are thus mainly a residential problem, like cooking fires, the most frequent cause of home fires, and smoking-material fires, the leading cause of home fire deaths.[7]

The home data show an unusual profile. Candles caused 5 percent of home fires and 5 percent of the deaths, or 0.9 deaths per 100 fires, close to the average of about 0.79 for all home fires.[7][17] They caused 11 percent of the injuries, however, about 9.0 injuries per 100 fires against 4.1 for all home fires. Among the leading causes, only fires started by playing with a heat source had a higher injury rate, about 9.7 per 100 fires.[7] The average direct loss per candle fire was 21,500 dollars, against about 14,400 dollars for an average home fire.[17] Together with intentional and electrical fires, candle fires had the largest average property loss per fire of the leading causes.[9]

Three small bar charts comparing deaths per 100 fires, injuries per 100 fires and average loss per fire for leading causes of US home fires
Deaths and injuries per 100 fires and average direct loss per fire for leading causes of US home structure fires, 1999–2002; candle highlighted. Based on Ahrens et al. (2008), p. 3-74.

In US one- and two-family dwellings, candles caused 14,400 fires a year (5 percent), 130 deaths (5 percent), 1,230 injuries (12 percent) and 304 million dollars of damage (7 percent).[18] Only cooking equipment caused more injuries in these dwellings.[19] Candles also rank among the most common sources of ignition of fatal fires in such homes.[20] In apartments their share of fires was slightly lower, 4 percent against 5 percent in one- and two-family dwellings.[21]

The trend ran against the overall decline in home fires. US home candle fires generally declined in the 1980s and reached their lowest point in 1990, then climbed again from 1991.[8] They rose 15 percent from 2000 to 2001 and stabilised in 2002, the first year since 1995 without a new high. Because total home fires fell sharply over the same period, the candle share grew from 1 percent in the early 1980s to 5 percent in 2001 and 2002.

The items that candles ignite explain part of the toll. In US homes in 1999–2002, candles started 900 upholstered furniture fires a year, with 17 deaths, and 1,700 mattress and bedding fires, with 33 deaths.[14][6] These two item groups thus accounted for about 14 percent of home candle fires but 31 percent of the deaths. Candles caused 13 percent of the injuries in upholstered furniture fires and 16 percent of those in mattress and bedding fires.

How a candle flame works

A candle burns in steps. When it is lit, the heat of the match melts the wax, which rises up the wick and is turned into vapour by the heat of the flame.[22] Melting is a physical change, and the wax can burn chemically only once it has evaporated.[23] The wax vapour then combines with oxygen from the surrounding air and produces heat and light in the form of a flame. Part of the heat of the flame flows back to the solid fuel and keeps this evaporation going.[24]

The candle flame is the classic laminar diffusion flame, in which fuel and oxygen meet from opposite sides of the reaction zone.[25] Oxygen reaches the flame only by slow diffusion, so the outer part of a candle flame is the hottest.[26] The flame has three zones: an inner, non-luminous zone of relatively cool gas, a luminous zone at 590 to 680 °C, and a thin, invisible outer zone.[22] In the luminous zone, hydrogen and carbon monoxide from the decomposing wax react with oxygen, and free carbon particles glow before they are consumed. Blue parts of the flame indicate nearly complete combustion, while the yellow-orange light comes from glowing soot.[26]

Cross-section of a candle flame showing wick, molten wax, three flame zones and upward plume with sideways radiation
Anatomy of a candle flame: molten wax rises up the wick and burns as a laminar diffusion flame; most heat leaves upwards in the plume. Based on Iqbal and Salley (2004), pp. 3-8–3-10, and Drysdale (2008), p. 2-10.

Most of the heat leaves the flame upwards. The rising plume of hot gases carries 70 to 90 percent of the heat released, and up to 30 percent is lost as radiation in all directions.[27] A hand held beside the flame feels only the radiated part, whereas a hand held above it intercepts all of the convected heat. Materials above a candle are therefore exposed far more strongly than materials beside it.

A candle flame needs oxygen and goes out before the oxygen is used up. A candle under a lowered inverted beaker is extinguished by its own combustion products.[24] The Fire Dynamics Simulator guide uses the same picture, a candle in an inverted jar, as the classic example of a diffusion flame in vitiated air that extinguishes before it consumes all the oxygen.[28] In the standard oxygen index test, a kitchen candle still burns in an oxygen concentration of 16.0 percent, compared with 21 percent in normal air.[29][24]

Heat output and ignition potential

A burning candle releases about 80 W, which is less than a person at normal exertion.[3] A standard laboratory candle contains about 1,500 kJ of heat energy, released at about 50 W.[4] The energy released by a fire equals its power multiplied by the burning time, so the burning time follows from the stored energy and the heat release rate.[30] The rate at which wax is consumed follows in the same way from the heat release rate and the heat of combustion of the wax.

E=Q˙tm˙=Q˙ΔHc

Symbol Description Unit
E heat energy stored in or released by the candle J
Q˙ heat release rate of the candle flame W
t burning time s
m˙ mass burning rate of the wax kg/s
ΔHc heat of combustion of the wax J/kg

As a worked example, the laboratory candle burns for t=1500 kJ/50 W=30,000 s, or about 8.3 hours. Paraffin wax has a net heat of combustion of 43.1 MJ/kg (46.2 MJ/kg gross), so the candle holds about 35 g of wax.[31] At 50 W it burns about 1.16 mg/s, or 4.2 g per hour. The International Fire Engineering Guidelines (IFEG) give a similar calorific value of 47 MJ/kg.[32] For scale, an average living-room sofa fire of 2.5 MW releases as much heat as about 31,000 burning candles.[30]

A second estimate shows how quickly radiation from a candle falls with distance. The point source model treats the flame as a point that radiates a fraction of its heat release rate equally in all directions, so the radiant heat flux falls with the square of the distance.[33] It is conceptually the simplest way to represent a radiating flame.

q˙″=χrQ˙4πR2

Symbol Description Unit
q˙″ radiant heat flux at the target kW/m²
χr fraction of the heat release rate emitted as radiation –
Q˙ heat release rate of the flame kW
R distance from the centre of the flame to the target m

The radiated fraction ranges from about 0.15 for low-sooting fuels to 0.60 for high-sooting fuels.[33] Taking 0.30 as an illustrative upper bound for a candle's radiative loss, and 0.080 kW for its heat release rate, gives about 0.02 kW/m² at the recommended clearance of 305 mm.[27][5] At 50 mm the estimate rises to about 0.76 kW/m², and the model overestimates radiation this close to a flame.[34] By contrast, a small flame such as a wooden match applies 18 to 20 kW/m² to a surface it touches, about 900 times the radiant flux of a candle at 305 mm.[35] This illustrative calculation does not predict the likelihood of ignition or justify reducing the recommended clearance.

Log-scale line chart of radiant heat flux from a candle falling with distance, far below the flux of a flame in contact
Point-source estimate of radiant heat flux from an 80 W candle flame (radiated fraction 0.30) against distance, compared with the 18–20 kW/m² of a small flame in contact. Based on Iqbal and Salley (2004), p. 5-3.

Prevention and education

Fire and life safety education is the main tool against candle fires in homes. The NFPA Educational Messages Advisory Committee has issued official candle messages.[5] They advise keeping candles at least 305 mm (12 in.) from anything that can burn, using sturdy and safe candleholders, and never leaving a burning candle unattended. They also advise blowing candles out on leaving a room, avoiding candles in bedrooms and sleeping areas, and using a flashlight rather than a candle for emergency lighting.

Lit candle in a heavy stable holder on a clear table, with a flameless battery-operated candle beside it
Safe candle use: a sturdy, stable holder on a clear, non-combustible surface, well away from anything that can burn, and a flameless battery-operated alternative.

Messages must fit the culture of the audience. Many cultures use candles to celebrate holidays and religious events.[36] A message telling people never to use candles at home could offend such groups, whereas a message urging them to use candles wisely respects them, although it still names no concrete action.[5] In the United States, careless candle use was described as a growing problem with several distinct audiences.[37] Teenagers and young adults use candles for ambience, older people for scent, and poor households for lighting, and each group needs its own messages.

Where electricity is lacking or interrupted, candles become a light source rather than a decoration. In South African townships and informal settlements, a paraffin stove or a candle that tips over and starts a fire was identified as a common cause of burns to young children.[38] US disaster guidance advises avoiding candles and kerosene lamps during a hurricane and using flashlights instead.[39] After the storm, the same guidance asks people to practise safety when they use candles.[40]

Education cannot remove the hazard entirely. The handbook chapter on gases notes that it is impossible to prevent the use of candles in residential occupancies, which limits control of ignition sources there.[41] Programmes aimed at young children therefore address the adults, who store matches and lighters, use candles and maintain the smoke alarms.[42] Local data help to set priorities: in Hagerstown, Maryland, local data confirmed a significant share of candle fires, which were later flagged as an emerging problem after cooking fires had been reduced.[43]

Candles in non-residential buildings

In buildings with transient or public occupants, candle use is controlled by management rules. In US hotels and motels in 1999–2002, candles caused 120 fires a year (3 percent) and no deaths.[44] University housing often regulates open flames, including candles and incense.[45] In a lodging or rooming house, candles and fireplaces are the usual open flames, and many bed-and-breakfast owners ban candles in guest rooms or use battery-operated candles instead.[46] Such candles flicker realistically and give the ambience without the flame.

In assembly buildings, candles on restaurant tables call for the same care as tableside and flambé cooking.[47] In a place of worship, candles are a large part of many services, both fixed in place and carried by worshippers.[10] The handbook recommends written approval by a responsible official for open flames in cultural buildings, with combustible and valuable materials moved away and a trained fire watch present. US places of worship and funeral parlours had about 110 candle fires a year in 1999–2002, 6 percent of their fires.[48] Historic building museums often use candles and oil, gas or kerosene lamps for illumination, and every such flame has to be safeguarded and monitored.[49]

Candles have also caused serious industrial fires. On 22 March 1975, workers at the Browns Ferry nuclear power plant in Alabama used a candle to check for air leaks where cable trays passed through a wall.[11] The air flow drew the flame into newly installed polyurethane foam that sealed the openings, and the fire spread along the cables and shorted out backup safety systems. Temperatures reached 816 °C and damaged more than 1,600 cables in 117 conduits and 26 cable trays.[12]

Section through a wall penetration with cable trays, polyurethane foam seal and a candle flame drawn into the opening by air flow
Browns Ferry, 1975: air flowing through a cable penetration drew a test candle's flame into the polyurethane foam seal, and the fire spread along the cables. Based on Kampmeyer (2008), p. 18-73.

The Browns Ferry fire caused no serious injuries, but it led to 302.93 million dollars of damage in 2007 dollars and an outage of 1.5 years for two 1,065 MW units.[50] It also triggered a worldwide reappraisal of nuclear facility fire protection. The first fire risk assessment of a nuclear power plant was made in 1975 for this fire. It put the core damage frequency from such a fire at about 10−5 per year, about 20 percent of the total from the causes in the main study.[51] The fire showed that penetrations must be sealed against both fire and smoke, and it led to new sealing materials and practice in firestopping.[11]

Limits of the data and common misconceptions

Candle statistics have the same limits as other NFIRS heat-source data. They include a share of vaguely coded open-flame fires, the same fire can be counted under several causes, and the estimates are projections from a sample of US fire departments.[1] The data here describe the United States in 1999–2002, as summarised in a 2008 handbook, and the trend in candle fires was still changing at that time.[8] Because deaths per 100 candle fires are close to the average, the distinctive burden of candles lies more in injuries and property loss than in deaths.[7]

Its small size does not make a candle a minor hazard. A single candle can burn for several hours, and the historical US data include fires in which it ignited furniture or bedding.[4][14][6] In US homes, the furniture and bedding fires started by candles caused almost a third of all candle fire deaths.[6] The Browns Ferry fire showed that the same small flame can also start a major fire in industry.[50]

A general home ban is impractical, and messages that forbid candles can offend groups that use them for religious or family events.[41][5] The handbook guidance combines safe-use messages, supervision where candles form part of a ritual, and flameless alternatives where the light or ambience is what is wanted.[5][46][10]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 Hall and Cote (2008), p. 3-14.
  2. ↑ 2.0 2.1 Ahrens et al. (2008), p. 3-72.
  3. ↑ 3.0 3.1 Iqbal and Salley (2004), p. 3-2.
  4. ↑ 4.0 4.1 4.2 Iqbal and Salley (2004), p. C-1.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 Grant and Eksteen (2008), p. 5-24.
  6. ↑ 6.0 6.1 6.2 6.3 Babrauskas (2008b), p. 6-107.
  7. ↑ 7.0 7.1 7.2 7.3 7.4 7.5 7.6 Ahrens et al. (2008), p. 3-74.
  8. ↑ 8.0 8.1 8.2 Ahrens et al. (2008), p. 3-64.
  9. ↑ 9.0 9.1 Ahrens et al. (2008), p. 3-76.
  10. ↑ 10.0 10.1 10.2 McDaniel (2008), p. 20-185.
  11. ↑ 11.0 11.1 11.2 Kampmeyer (2008), p. 18-73.
  12. ↑ 12.0 12.1 Iqbal and Salley (2004), p. A-1.
  13. ↑ Ahrens et al. (2008), pp. 3-70–3-71.
  14. ↑ 14.0 14.1 14.2 Babrauskas (2008b), p. 6-106.
  15. ↑ Ahrens et al. (2008), p. 3-71.
  16. ↑ Hirschler (2008b), p. 18-37.
  17. ↑ 17.0 17.1 Ahrens et al. (2008), p. 3-75.
  18. ↑ Lathrop (2008b), p. 20-57.
  19. ↑ Lathrop (2008b), p. 20-59.
  20. ↑ Lathrop (2008b), p. 20-61.
  21. ↑ Bush (2008), p. 20-38.
  22. ↑ 22.0 22.1 Iqbal and Salley (2004), pp. 3-8–3-9.
  23. ↑ Van Rossum (2027), §3.5.
  24. ↑ 24.0 24.1 24.2 Yu and Newman (2008), p. 2-80.
  25. ↑ Iqbal and Salley (2004), p. 3-10.
  26. ↑ 26.0 26.1 Van Rossum (2027), §4.3.
  27. ↑ 27.0 27.1 Drysdale (2008), p. 2-10.
  28. ↑ McGrattan et al. (2026), p. 62.
  29. ↑ Babrauskas (2008a), p. 6-282.
  30. ↑ 30.0 30.1 Van Rossum (2027), §4.5.
  31. ↑ Babrauskas (2008a), p. 6-280.
  32. ↑ National Research Council of Canada et al. (2005), p. 3.3-6.
  33. ↑ 33.0 33.1 Iqbal and Salley (2004), p. 5-3.
  34. ↑ Iqbal and Salley (2004), p. 5-17.
  35. ↑ Babrauskas (2008b), p. 6-118.
  36. ↑ Grant and Eksteen (2008), p. 5-23.
  37. ↑ Kirtley (2008b), p. 5-11.
  38. ↑ Grant and Eksteen (2008), p. 5-26.
  39. ↑ Penney (2008), p. 5-38.
  40. ↑ Penney (2008), p. 5-34.
  41. ↑ 41.0 41.1 Lemoff (2008), p. 6-175.
  42. ↑ Gamache (2008), p. 5-64.
  43. ↑ Hall and Weller (2008), pp. 5-123, 5-136.
  44. ↑ Berkol et al. (2008), p. 20-27.
  45. ↑ Berkol et al. (2008), p. 20-31.
  46. ↑ 46.0 46.1 Anderson (2008b), p. 20-50.
  47. ↑ Miller and Roether (2008), p. 20-91.
  48. ↑ McDaniel (2008), p. 20-182.
  49. ↑ McDaniel (2008), p. 20-200.
  50. ↑ 50.0 50.1 Sheridan (2008), p. 9-187.
  51. ↑ Siu (2002), p. 5-222.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Anderson, R. R. (2008b). Lodging or rooming houses. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-49–20-54). National Fire Protection Association.
  • Babrauskas, V. (2008a). Tables and charts. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-269–6-294). National Fire Protection Association.
  • Babrauskas, V. (2008b). Upholstered furniture and mattresses. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-103–6-128). National Fire Protection Association.
  • Berkol, A., Briese, B., & Comeau, E. (2008). Hotels and university housing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-23–20-36). National Fire Protection Association.
  • Bush, K. (2008). Apartment buildings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-37–20-47). National Fire Protection Association.
  • Drysdale, D. (2008). Physics and chemistry of fire. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-3–2-20). National Fire Protection Association.
  • Gamache, S. (2008). Reaching high-risk groups. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-63–5-85). National Fire Protection Association.
  • Grant, E., & Eksteen, R. (2008). Fire and life safety education messages. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-21–5-27). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Hall, J. R., Jr., & Weller, M. W. (2008). Evaluation techniques for fire and life safety education. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-119–5-137). National Fire Protection Association.
  • Hirschler, M. M. (2008b). Interior finish. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 18-23–18-42). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Kampmeyer, J. E. (2008). Penetration sealing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 18-73–18-78). National Fire Protection Association.
  • Kirtley, E. (2008b). Principles and techniques of fire and life safety education. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-3–5-20). National Fire Protection Association.
  • Lathrop, J. K. (2008b). One- and two-family dwellings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-55–20-61). National Fire Protection Association.
  • Lemoff, T. C. (2008). Gases. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-165–6-186). National Fire Protection Association.
  • McDaniel, D. L. (2008). Library and museum collections. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-179–20-202). National Fire Protection Association.
  • McGrattan, K., Hostikka, S., Floyd, J., McDermott, R., Vanella, M., Mueller, E., & Paul, C. (2026). Fire Dynamics Simulator technical reference guide: Vol. 1. Mathematical model (6th ed., NIST Special Publication 1018-1). National Institute of Standards and Technology. https://doi.org/10.6028/NIST.SP.1018
  • Miller, G., & Roether, E. (2008). Assembly occupancies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-85–20-95). National Fire Protection Association.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Penney, G. (2008). Disaster preparedness education. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-29–5-43). National Fire Protection Association.
  • Sheridan, D. J. (2008). Electric generating plants. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 9-179–9-189). National Fire Protection Association.
  • Siu, N. (2002). Fire risk assessment for nuclear power plants. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 5-214–5-226). National Fire Protection Association; Society of Fire Protection Engineers.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.
  • Yu, H.-Z., & Newman, J. S. (2008). Theory of fire extinguishment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 2-79–2-92). National Fire Protection Association.