Critical ambient temperatures reported by Gray: stacking 18 kegs of 14 kg lowered the value from 62.5 °C to 54 °C, and still air instead of stirred oven air lowered it from 60 °C to 55 °C for a 0.175 m radius container of hydrated calcium hypochlorite. Based on Gray (2002), pp. 2-222–2-223.

Original illustration for Organic peroxide.

  • Source basis: Gray (2002), pp. 2-222–2-223
  • Alt text: Bar chart: critical ambient temperature 62.5 °C for one keg and 54 °C for 18 kegs; 60 °C in stirred air and 55 °C in still air for calcium hypochlorite.