Summary

The intermediate-scale calorimeter (ICAL): a vertical gas-fired radiant panel heats a 1 m × 1 m specimen on a weighing platform; a collection hood above captures the combustion products for oxygen consumption calorimetry. Based on Madrzykowski and Stroup (2008), p. 2-41 and Hirschler (2008a), p. 6-48.

Original illustration for Intermediate-scale calorimeter.

  • Source basis: Madrzykowski and Stroup (2008), p. 2-41, Figure 2.3.10 (redraw, do not copy); Babrauskas (2002b), p. 3-5, Figure 3-1.5 (same apparatus; redraw, do not copy); Hirschler (2008a), p. 6-48 (vertical gas-fired panel, up to 50 kW/m²); Janssens (2002), p. 3-57 (panel and flat specimen parallel beneath hood and exhaust system)
  • Alt text: Side view of the ICAL: vertical radiant panel facing a 1 m square specimen on a weighing platform, with wire igniters and a hood above.