Skip to content
From Fire Safety Academy Wiki
Revision as of 07:51, 8 November 2026 by Lisa (talk | contribs) (Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Contents
  1. 1Summary
  2. 2Licensing

Fse-foam-plastic-insulation-v1.svg (SVG file, nominally 1,210 × 700 pixels, file size: 7 KB)

Summary

Thermal inertia (square root of conductivity × density × specific heat) of polyurethane foam compared with common building materials. The low value of the foam means that its surface heats up very quickly. Based on Van Rossum (2027), §5.2 and §5.5.

Original illustration for Foam plastic insulation.

  • Source basis: Van Rossum (2027), §5.2 (definition, low thermal inertia of light insulation) and §5.5 (property table)
  • Alt text: Bar chart on a log scale: thermal inertia of polyurethane foam about 31, softwood 505, oak 569, gypsum plaster 762 and concrete 2,012.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current07:51, 8 November 2026Thumbnail for version as of 07:51, 8 November 20261,210 × 700 (7 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata