Summary
Principle of the flame spread index: the flame front distance is recorded over the 10-minute test and the area under the curve is compared with that of red oak flooring (about 100) and cement board (0). Schematic, not measured data. Based on Hirschler (2008a), p. 6-43 and Hirschler (2008b), p. 18-26.
Original illustration for Flame spread index.
- Source basis: Hirschler (2008a), p. 6-43 (area under flame spread distance-time curve; 0 for cement board, about 100 for red oak); Hirschler (2008b), p. 18-26 (calibration, 10-minute test, comparison with two reference materials)
- Alt text: Schematic chart of flame front distance against time: red oak reaches 7.3 m at 5.5 minutes, a test material spreads less, cement board stays at zero.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 08:13, 8 November 2026 | 1,190 × 879 (9 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |