Fse-restrained-thermal-expansion-v3.svg (SVG file, nominally 900 × 600 pixels, file size: 8 KB)
Summary
Walk-off of the girder at Column 79 of WTC 7: floor beams framing in from one side expand, shear the seat bolts and push the girder off its 11 in. (279 mm) bearing seat after 5.5 in. (140 mm).
Original illustration for Restrained thermal expansion, level 4 Expert.
- Alt text: Plan of floor beams pushing a girder sideways from one side, and a section of the girder sliding off an 11 inch seat after 5.5 inches.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:26, 2 November 2026 | 900 × 600 (8 KB) | Jan (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |