Other chapters of the same handbook draw the boundaries differently. Denlinger (2008) defines total reflex time as the time from receipt of the call until the units arrive on scene, which excludes access and setup.<ref name="Denlinger-12-73">Denlinger (2008), p. 12-73.</ref> Custer and Sheppard (2008), writing on fire investigation, split the response time into detection, alarm transmission, dispatch, travel and the time from arrival to agent application.<ref name="CusterSheppard-3-38">Custer and Sheppard (2008), p. 3-38.</ref> The International Fire Engineering Guidelines (2005) use a notification time, when the fire service becomes aware of the alarm. They then define a dispatch time from notification until the vehicles leave the station, so that this interval also covers the turnout of the crew, and an arrival time.<ref name="IFEG-1.9-2">National Research Council of Canada et al. (2005), p. 1.9-2.</ref>
Other chapters of the same handbook draw the boundaries differently. Denlinger (2008) defines total reflex time as the time from receipt of the call until the units arrive on scene, which excludes access and setup.<ref name="Denlinger-12-73">Denlinger (2008), p. 12-73.</ref> Custer and Sheppard (2008), writing on fire investigation, split the response time into detection, alarm transmission, dispatch, travel and the time from arrival to agent application.<ref name="CusterSheppard-3-38">Custer and Sheppard (2008), p. 3-38.</ref> The International Fire Engineering Guidelines (2005) use a notification time, when the fire service becomes aware of the alarm. They then define a dispatch time from notification until the vehicles leave the station, so that this interval also covers the turnout of the crew, and an arrival time.<ref name="IFEG-1.9-2">National Research Council of Canada et al. (2005), p. 1.9-2.</ref>
[[File:fse-emergency-response-time-v1.svg|thumb|upright=1.5|alt=Time line with event, call, dispatch, acknowledgement, wheels rolling, arrival and water application, and bars for each definition|Time stamps of an emergency response and the intervals covered by different definitions of response time.]]


To create uniformity in how response time is defined, NFPA 450 sets out discrete time stamps, functional intervals and process intervals. Krakeel (2008) reproduces its EMS time template from the 2004 edition, which lists 18 time stamps from "event occurs" to "available for service".<ref name="Krakeel-13-157-158">Krakeel (2008), pp. 13-157–13-158.</ref> In that template, call processing runs from the phone ringing at the first answering point to unit acknowledgement, and unit response from acknowledgement to arrival. The turnout interval ends when the wheels start turning and the travel interval when they stop at the scene.<ref name="Krakeel-13-158">Krakeel (2008), p. 13-158.</ref> A reported response time therefore has meaning only when its start and end points are stated.
To create uniformity in how response time is defined, NFPA 450 sets out discrete time stamps, functional intervals and process intervals. Krakeel (2008) reproduces its EMS time template from the 2004 edition, which lists 18 time stamps from "event occurs" to "available for service".<ref name="Krakeel-13-157-158">Krakeel (2008), pp. 13-157–13-158.</ref> In that template, call processing runs from the phone ringing at the first answering point to unit acknowledgement, and unit response from acknowledgement to arrival. The turnout interval ends when the wheels start turning and the travel interval when they stop at the scene.<ref name="Krakeel-13-158">Krakeel (2008), p. 13-158.</ref> A reported response time therefore has meaning only when its start and end points are stated.
Line 62: Line 63:


As an illustration, adding the NFPA 1221 dispatch objective (60 s), the NFPA 1710 turnout (60 s) and the 4-minute first-engine objective gives 6 minutes from receipt of the alarm to arrival. With the 8-minute first-alarm objective the sum is 10 minutes. These sums match an example standards of cover statement quoted by Johnson and Price (2008). It gives 4 minutes of travel or 6 minutes of total reflex time for the first-due unit, and 8 or 10 minutes for the effective response force.<ref name="JP-12-222" />  
As an illustration, adding the NFPA 1221 dispatch objective (60 s), the NFPA 1710 turnout (60 s) and the 4-minute first-engine objective gives 6 minutes from receipt of the alarm to arrival. With the 8-minute first-alarm objective the sum is 10 minutes. These sums match an example standards of cover statement quoted by Johnson and Price (2008). It gives 4 minutes of travel or 6 minutes of total reflex time for the first-due unit, and 8 or 10 minutes for the effective response force.<ref name="JP-12-222" />  
[[File:fse-emergency-response-time-v2.svg|thumb|upright=1.5|alt=Two stacked bars: 60 s dispatch, 60 s turnout and 240 s travel make 6 min; with 480 s travel 10 min|Illustrative sum of NFPA objectives as described in 2008: dispatch 60 s, turnout 60 s and travel 240 s or 480 s give 6 and 10 minutes from alarm to arrival.]]


Granito (2008) gives similar rules of thumb. A full first alarm from staffed stations should be on scene within about 10 minutes of the alarm, about 8 minutes of running time. A volunteer station without duty crew may need 6 minutes or longer before a crewed vehicle leaves, so a 6-minute run takes about 12 minutes from call to scene.<ref name="Granito-12-8">Granito (2008), p. 12-8.</ref>
Granito (2008) gives similar rules of thumb. A full first alarm from staffed stations should be on scene within about 10 minutes of the alarm, about 8 minutes of running time. A volunteer station without duty crew may need 6 minutes or longer before a crewed vehicle leaves, so a 6-minute run takes about 12 minutes from call to scene.<ref name="Granito-12-8">Granito (2008), p. 12-8.</ref>
Line 75: Line 77:


An example performance report for July to December 2007 in Cline (2008) shows why the fraction matters. The operational goal is a response time of 4 minutes or less, 90 percent of the time. In the reporting period the average response time is 3 minutes 52 seconds, below the goal, yet only 69 percent of responses arrive within 4 minutes.<ref name="Cline-12-36">Cline (2008), p. 12-36.</ref> In this worked example, 31 percent of responses take longer than 4 minutes, so compliance is 21 percentage points below the goal although the average is under 4 minutes. The report names detours on 20 percent of the major traffic corridors in one part of the community as an explanatory factor. It also plans a dispatch display in multi-company stations to shorten turnout.<ref name="Cline-12-36" />
An example performance report for July to December 2007 in Cline (2008) shows why the fraction matters. The operational goal is a response time of 4 minutes or less, 90 percent of the time. In the reporting period the average response time is 3 minutes 52 seconds, below the goal, yet only 69 percent of responses arrive within 4 minutes.<ref name="Cline-12-36">Cline (2008), p. 12-36.</ref> In this worked example, 31 percent of responses take longer than 4 minutes, so compliance is 21 percentage points below the goal although the average is under 4 minutes. The report names detours on 20 percent of the major traffic corridors in one part of the community as an explanatory factor. It also plans a dispatch display in multi-company stations to shorten turnout.<ref name="Cline-12-36" />
[[File:fse-emergency-response-time-v3.svg|thumb|upright=1.5|alt=Left: average 3 min 52 s below a 4 min objective line. Right: 69 percent compliance bar below a 90 percent goal line|Example performance report: the average response time (3 min 52 s) meets the 4-minute objective, but only 69 percent of responses do, against a 90 percent goal.]]


Data for such reports come from CAD records or manual logs and can be analysed by time of day and day of the week.<ref name="JP-12-222" /> Krakeel (2008) warns that in many EMS systems the contributions of the various agencies to the overall response time are not separated or analysed. Without coordination and review, the call processing, turnout, travel and handover times have little value for judging whether the system performs as expected.<ref name="Krakeel-13-153-154">Krakeel (2008), pp. 13-153–13-154.</ref> NFPA 450 time stamps are intended to make the values of different agencies comparable.<ref name="Krakeel-13-157" />
Data for such reports come from CAD records or manual logs and can be analysed by time of day and day of the week.<ref name="JP-12-222" /> Krakeel (2008) warns that in many EMS systems the contributions of the various agencies to the overall response time are not separated or analysed. Without coordination and review, the call processing, turnout, travel and handover times have little value for judging whether the system performs as expected.<ref name="Krakeel-13-153-154">Krakeel (2008), pp. 13-153–13-154.</ref> NFPA 450 time stamps are intended to make the values of different agencies comparable.<ref name="Krakeel-13-157" />
Line 102: Line 105:


The authors state that the factor is empirical, not derived from first principles. It gives a 5-minute difference more weight when typical responses take 10 to 15 minutes than when they take 30 to 35.<ref name="Hyslop-14-7">Hyslop et al. (2010), p. 14-7.</ref> As an illustration, take the revised suppression rate for electrical fires, 0.102 per minute, an available time of 15 minutes and a typical response of 10 minutes.<ref name="Hyslop-14-11">Hyslop et al. (2010), p. 14-11.</ref> A typical response gives <math>C_s = 1</math> and a non-suppression probability of exp(−0.102 × 15) = 0.22. A 20-minute response, for example to a hard-to-reach room, gives <math>C_s = 0.67</math> and 0.36, while a 4-minute response gives <math>C_s = 1.43</math> and 0.11. The supplement also found that many plant fires are suppressed before the brigade arrives in full.<ref name="Hyslop-14-8">Hyslop et al. (2010), p. 14-8.</ref>
The authors state that the factor is empirical, not derived from first principles. It gives a 5-minute difference more weight when typical responses take 10 to 15 minutes than when they take 30 to 35.<ref name="Hyslop-14-7">Hyslop et al. (2010), p. 14-7.</ref> As an illustration, take the revised suppression rate for electrical fires, 0.102 per minute, an available time of 15 minutes and a typical response of 10 minutes.<ref name="Hyslop-14-11">Hyslop et al. (2010), p. 14-11.</ref> A typical response gives <math>C_s = 1</math> and a non-suppression probability of exp(−0.102 × 15) = 0.22. A 20-minute response, for example to a hard-to-reach room, gives <math>C_s = 0.67</math> and 0.36, while a 4-minute response gives <math>C_s = 1.43</math> and 0.11. The supplement also found that many plant fires are suppressed before the brigade arrives in full.<ref name="Hyslop-14-8">Hyslop et al. (2010), p. 14-8.</ref>
[[File:fse-emergency-response-time-v4.svg|thumb|upright=1.5|alt=Three falling curves of non-suppression probability against available time for fast, typical and slow brigade response|Illustrative non-suppression probability for electrical fires (λ = 0.102 per minute) with a typical 10-minute brigade response (Cs = 1), a 4-minute response (Cs = 1.43) and a 20-minute response (Cs = 0.67).]]


== Reducing response time and its limits ==
== Reducing response time and its limits ==

Latest revision as of 18:25, 14 November 2026

Emergency response time is the time a fire or emergency medical service needs to get from an alarm to the incident, and in its wider sense to the start of fire fighting or patient care. The term is used with different start and end points. In the narrow sense of NFPA 1710, as described by Johnson and Price (2008), response time runs only from the moment units are en route until they arrive at the scene.[1] The wider total reflex time adds the dispatch and turnout steps before travel and the access and setup steps after it.[2]

Response time matters because fires grow quickly and some medical emergencies need help within minutes. The time between ignition and the start of suppression has a direct relationship to fire loss.[3] It is also the measure most often used to judge an emergency medical services (EMS) system.[4] Standards and accreditation schemes therefore set time objectives that must be met in a stated share of incidents, typically 90 percent.[1][5] Fire engineers estimate fire service arrival in performance-based design, and nuclear plant risk analysts use brigade response times in suppression models.[6][7] The benchmarks below are historical values from the cited editions.

Definitions and time stamps

Johnson and Price (2008) describe five steps in the total reflex time of a fire department after an alarm is received. Dispatch time covers receiving and processing the call. Turnout time runs from the moment units acknowledge the alarm until travel begins. Response time is the travel from "wheel start to wheel stop". Access time is the movement of the crew from the apparatus to the emergency, and setup time the preparation needed to start extinguishing.[2] NFPA 1710, as described by the same authors, defines dispatch time as running from receipt of the alarm at the public safety answering point until units are notified.[1]

Other chapters of the same handbook draw the boundaries differently. Denlinger (2008) defines total reflex time as the time from receipt of the call until the units arrive on scene, which excludes access and setup.[8] Custer and Sheppard (2008), writing on fire investigation, split the response time into detection, alarm transmission, dispatch, travel and the time from arrival to agent application.[9] The International Fire Engineering Guidelines (2005) use a notification time, when the fire service becomes aware of the alarm. They then define a dispatch time from notification until the vehicles leave the station, so that this interval also covers the turnout of the crew, and an arrival time.[10]

Time line with event, call, dispatch, acknowledgement, wheels rolling, arrival and water application, and bars for each definition
Time stamps of an emergency response and the intervals covered by different definitions of response time.

To create uniformity in how response time is defined, NFPA 450 sets out discrete time stamps, functional intervals and process intervals. Krakeel (2008) reproduces its EMS time template from the 2004 edition, which lists 18 time stamps from "event occurs" to "available for service".[11] In that template, call processing runs from the phone ringing at the first answering point to unit acknowledgement, and unit response from acknowledgement to arrival. The turnout interval ends when the wheels start turning and the travel interval when they stop at the scene.[12] A reported response time therefore has meaning only when its start and end points are stated.

Why minutes matter

Fire growth sets the first limit. Depending on room size, contents and available oxygen, flashover can occur in less than 2 or more than 10 minutes, most often between 4 and 10 minutes. Its exact time cannot be predicted.[3] Van Rossum (2027) describes the stages of a compartment fire: in the growth phase the fire is local and fuel-controlled, and after flashover it is a developed fire, usually ventilation-controlled.[13] The decay phase can start because the fuel runs out or because the fire brigade intervenes.[13] Whether the brigade still meets a local fire or already a fully involved compartment is important for its intervention.[14]

A fire that has passed flashover burns hotter and spreads faster, so search and rescue become harder just when more fire fighters are needed for the attack.[3] Custer and Sheppard (2008) note that, without automatic suppression, the response time of the fire department influences the size of the fire when a suppression agent is first applied.[9] Granito (2008) quotes an old adage that the first 5 minutes of most fires decide whether a fire stays small or becomes large, adding that this may not always be true.[15]

Medical emergencies set a second limit. Johnson and Price (2008) report that a heart attack victim whose cardiopulmonary resuscitation (CPR) starts within four minutes has an almost four times greater chance of leaving hospital alive. They reproduce survival rates of 28 percent with CPR in four minutes or less and 7 percent with later CPR.[16] The handbook bibliography identifies the source of those rates as a 1987 American Heart Association manual.[17]

Krakeel (2008) traces EMS time standards to studies by Michael Eisenberg in the late 1970s. Patients who received CPR in the first 4 to 6 minutes, followed by advanced care within 8 minutes, had a higher probability of survival. The 8-minute standard for advanced life support was later widely adopted.[4]

Components of the time line

The total reflex time is the sum of its five steps. Dispatch and turnout take place before the crew leaves the station, and access and setup at the incident. As an illustration of the time accounting described by Johnson and Price (2008), the time from receipt of the alarm to the start of operations is:[2]

treflex=tdisp+tturn+ttrav+tacc+tset

The time before the alarm reaches the fire department is not part of this sum, but it is part of the time that the fire grows. Johnson and Price (2008) call the interval from ignition through discovery to reporting indirectly manageable. It can be shortened by automatic detection or suppression systems and automatic reporting to the public safety answering point. The authors note the increasing use of smoke detectors in homes, but also that automatic reporting was lacking.[18]

In the MGM Grand Hotel fire in Clark County, Nevada, on 21 November 1980, the fire was discovered at about 7:10 a.m. The fire department was notified at 7:17 a.m. Its first company arrived at about 7:18 a.m. from a station across the street, and flashover and spread through the casino followed immediately.[19]

Dispatch time depends on how alarms are received and processed in the emergency communications centre; enhanced 9-1-1 and computer-aided dispatch (CAD) can minimise it.[2] Turnout time can be managed to some degree by better communication between the dispatch centre and the station.[2] Acomb and LeBoeuf (2008) note that the key time in a station is getting equipment out of the door, so the design should minimise the travel time of personnel to the vehicles.[20] Turnout is typically longer for call and volunteer departments.[21] Denlinger (2008) reports that career crews who bring the apparatus while volunteers go directly to the fire save an average of about 3 minutes in arrival time.[22]

Travel time is one of the most manageable segments, mainly through fire station location and the most efficient route.[2] Weather, terrain, traffic and the condition of the apparatus can extend it, and equipment failures or out-of-service apparatus can delay the whole response.[9] Comly (2008) adds that limited-access highways may divide a community and delay travel to locations between access points.[23] Access time can be reduced by pre-fire planning, key boxes and cooperation with site security. Setup includes laying and charging hose lines, donning breathing apparatus and entering the building before fire fighting starts, and the opportunity to save time here is minimal, even for trained personnel.[2]

Symbol Description Unit
treflex Total reflex time from receipt of alarm to start of operations min
tdisp Dispatch time: call receipt to notification of units min
tturn Turnout time: acknowledgement to start of travel min
ttrav Travel time (response time in the narrow NFPA 1710 sense) min
tacc Access time: apparatus to the emergency min
tset Setup time: preparation to apply water min
f Fraction of incidents meeting a time objective –
N Number of incidents in the reporting period –
Tobj Time objective, for example 4 min travel min

Benchmarks described in 2008

NFPA 1221, as described by Johnson and Price (2008), requires 95 percent of alarms to be answered within 15 seconds and 99 percent within 40 seconds. Dispatch must be completed within 60 seconds in at least 95 percent of cases.[1] The alarm time line taken from the 2007 edition adds a target of 90 seconds for 99 percent of dispatches.[24] NFPA 1710 sets for career departments a turnout time of 60 seconds and 4 minutes or less for the first engine company at a fire. It also sets 8 minutes or less for the full first-alarm assignment, 4 minutes for a first-responder EMS unit and 8 minutes for an advanced life support unit where the department provides one. Each objective is to be achieved in at least 90 percent of incidents.[1]

NFPA 1720 applies to volunteer departments and relates response times to population density.[1] Granito (2008) explains that it recognises the difference between crews in the station and volunteers who are likely elsewhere. It therefore sets minimum crew numbers and maximum response times that depend on population density per square mile. Granito describes both standards as created in 2001 and discusses their 2004 editions.[25]

Accreditation bodies add their own values. Krakeel (2008) reports that the Commission on Fire Accreditation International (CFAI) required a 60-second turnout in urban and suburban communities. For urban and suburban communities, the Commission on Accreditation of Ambulance Services (CAAS) allowed 8 minutes 59 seconds for an advanced life support ambulance to reach life-threatening emergencies, counted from notification of the unit.[4] Compliance with 8:59 in 90 percent of such calls was widely used in ambulance contracts.[5] For Medicare payment, the Centers for Medicare Services defined an emergency response as one in which resources are mobilised and responding within 5 minutes of notification.[4]

As an illustration, adding the NFPA 1221 dispatch objective (60 s), the NFPA 1710 turnout (60 s) and the 4-minute first-engine objective gives 6 minutes from receipt of the alarm to arrival. With the 8-minute first-alarm objective the sum is 10 minutes. These sums match an example standards of cover statement quoted by Johnson and Price (2008). It gives 4 minutes of travel or 6 minutes of total reflex time for the first-due unit, and 8 or 10 minutes for the effective response force.[21]

Two stacked bars: 60 s dispatch, 60 s turnout and 240 s travel make 6 min; with 480 s travel 10 min
Illustrative sum of NFPA objectives as described in 2008: dispatch 60 s, turnout 60 s and travel 240 s or 480 s give 6 and 10 minutes from alarm to arrival.

Granito (2008) gives similar rules of thumb. A full first alarm from staffed stations should be on scene within about 10 minutes of the alarm, about 8 minutes of running time. A volunteer station without duty crew may need 6 minutes or longer before a crewed vehicle leaves, so a 6-minute run takes about 12 minutes from call to scene.[26]

Reported values often lack such definitions. For the New York City Fire Department, Keough and Grill (2005) report an average response time of less than 5 minutes in 2001, without defining its end points.[27] Johnson and Price (2008) stress that each community must decide its own response and travel times. Shorter times need more stations, and rural regions normally have longer times than urban areas.[28] A standards of cover process turns such choices into written objectives for each risk class.[21]

Measuring and reporting performance

Time objectives in the standards are expressed as a fraction of incidents, not as an average. NFPA 1710 requires a performance objective of not less than 90 percent for each time objective.[1] As an illustration of calculating compliance, the fraction meeting an objective is the number of incidents whose time is at or below the objective, divided by the total number in the period:

f=N(t≤Tobj)N≥0.90

Cline (2008) lists among useful measures the actual and average response times, the percentage of responses under a given number of minutes, and dispatch, turnout and travel time separately.[29] Krakeel (2008) notes that analysing such functional intervals shows whether a change is needed and which agency is responsible for making it.[4] Recorded dispatch and turnout times are also the usual basis for the planning values used in station location studies.[21]

An example performance report for July to December 2007 in Cline (2008) shows why the fraction matters. The operational goal is a response time of 4 minutes or less, 90 percent of the time. In the reporting period the average response time is 3 minutes 52 seconds, below the goal, yet only 69 percent of responses arrive within 4 minutes.[30] In this worked example, 31 percent of responses take longer than 4 minutes, so compliance is 21 percentage points below the goal although the average is under 4 minutes. The report names detours on 20 percent of the major traffic corridors in one part of the community as an explanatory factor. It also plans a dispatch display in multi-company stations to shorten turnout.[30]

Left: average 3 min 52 s below a 4 min objective line. Right: 69 percent compliance bar below a 90 percent goal line
Example performance report: the average response time (3 min 52 s) meets the 4-minute objective, but only 69 percent of responses do, against a 90 percent goal.

Data for such reports come from CAD records or manual logs and can be analysed by time of day and day of the week.[21] Krakeel (2008) warns that in many EMS systems the contributions of the various agencies to the overall response time are not separated or analysed. Without coordination and review, the call processing, turnout, travel and handover times have little value for judging whether the system performs as expected.[31] NFPA 450 time stamps are intended to make the values of different agencies comparable.[4]

Response time in fire engineering and risk analysis

In performance-based building design, fire service arrival is one input among several. The International Fire Engineering Guidelines (2005) treat fire service intervention as a separate sub-system, which estimates notification, dispatch, arrival, investigation, set-up, search and rescue, and fire attack times.[32] The guidelines state that the evacuation analysis should not rely on fire service intervention.[6] They also note that the times may change over the life of a building with changes in station location, budgets and traffic.[10] A fire service arriving after the growth stage, beyond flashover, may have no effect on the design fire.[33]

In Australia the main tool is the Fire Brigade Intervention Model (FBIM), developed by the Australasian Fire Authorities Council (AFAC). It uses up to 16 flow charts, including the times to dispatch resources, to leave the station and to reach the fire scene kerbside.[34] The Fire Safety Verification Method Standard 2022 requires the FBIM for its fire brigade intervention scenario, which applies only to buildings within 50 km of road travel from a fire station.[35] The ABCB's 2020 handbook says that, in some cases without monitored detection, one may conservatively assume brigade arrival after flashover.[36] The New Zealand commentary on Verification Method C/VM2 (2013) states that fire service intervention is not normally used in design decisions.[37] Van Rossum (2027) notes that a stationary zone-model calculation may take the start of brigade intervention as its assessment moment.[38]

Fire risk assessments for US nuclear power plants use plant fire brigade response times explicitly. NUREG/CR-6850 (2005) models the probability that a fire is not yet suppressed at time t as exp⁡(−λt), with a suppression rate λ fitted to fire event data. It takes the time available for manual suppression as the time to target damage minus the brigade response time minus the detection time.[39] Supplement 1 (2010) dropped the separate subtraction, because the fire duration data already include the brigade response, and called the earlier treatment conservative.[40] Where a scenario's brigade response is expected to differ by more than 5 minutes from the typical one, the supplement permits a scenario-specific adjustment to the time in its nonsuppression model:[7]

Pns=exp⁡(−λtCs),Cs=1−Tfb,s−Tfb,tTfb,s+Tfb,t

Symbol Description Unit
Pns Probability that the fire is not suppressed in the available time –
λ Mean suppression rate for the fire type 1/min
t Time to target damage minus time to detection min
Cs Scenario-specific adjustment factor –
Tfb,s, Tfb,t Mean scenario-specific and typical brigade response times min

The authors state that the factor is empirical, not derived from first principles. It gives a 5-minute difference more weight when typical responses take 10 to 15 minutes than when they take 30 to 35.[41] As an illustration, take the revised suppression rate for electrical fires, 0.102 per minute, an available time of 15 minutes and a typical response of 10 minutes.[42] A typical response gives Cs=1 and a non-suppression probability of exp(−0.102 × 15) = 0.22. A 20-minute response, for example to a hard-to-reach room, gives Cs=0.67 and 0.36, while a 4-minute response gives Cs=1.43 and 0.11. The supplement also found that many plant fires are suppressed before the brigade arrives in full.[43]

Three falling curves of non-suppression probability against available time for fast, typical and slow brigade response
Illustrative non-suppression probability for electrical fires (λ = 0.102 per minute) with a typical 10-minute brigade response (Cs = 1), a 4-minute response (Cs = 1.43) and a 20-minute response (Cs = 0.67).

Reducing response time and its limits

Johnson and Price (2008) call reducing response time the most effective way to improve outcomes in both fire and medical emergencies. Measuring each step against its objective provides the basis for judging the cost of reducing it.[28] Global positioning system (GPS) tracking lets dispatchers see unit positions and dispatch according to availability, and GIS routing can show the quickest path on a screen in the vehicle.[44] Faster travel is limited by safety: Granito (2008) states that time cannot become the all-important factor at the expense of safety. Some departments run to certain calls without warning devices, obeying all traffic laws.[15]

Granito (2008) states that suppression capability can never be expected to compensate totally for missing built-in protection.[45] Comly (2008) notes that lengthy response times may dictate greater built-in fire protection.[23] The values in this article are those described in the 2008 handbook and its sources. They reflect a period in which US fire department workload more than doubled between 1980 and 2004, and medical calls came to make up three-fifths of all calls.[46]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Johnson and Price (2008), p. 12-220.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 Johnson and Price (2008), p. 12-218.
  3. ↑ 3.0 3.1 3.2 Johnson and Price (2008), p. 12-217.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 Krakeel (2008), p. 13-157.
  5. ↑ 5.0 5.1 Krakeel (2008), p. 13-155.
  6. ↑ 6.0 6.1 National Research Council of Canada et al. (2005), p. 1.9-1.
  7. ↑ 7.0 7.1 Hyslop et al. (2010), p. 14-4.
  8. ↑ Denlinger (2008), p. 12-73.
  9. ↑ 9.0 9.1 9.2 Custer and Sheppard (2008), p. 3-38.
  10. ↑ 10.0 10.1 National Research Council of Canada et al. (2005), p. 1.9-2.
  11. ↑ Krakeel (2008), pp. 13-157–13-158.
  12. ↑ Krakeel (2008), p. 13-158.
  13. ↑ 13.0 13.1 Van Rossum (2027), §4.11.
  14. ↑ Van Rossum (2027), §9.3 (Results from zone models).
  15. ↑ 15.0 15.1 Granito (2008), p. 12-14.
  16. ↑ Johnson and Price (2008), pp. 12-218–12-219.
  17. ↑ Johnson and Price (2008), p. 12-231.
  18. ↑ Johnson and Price (2008), pp. 12-217–12-218.
  19. ↑ Bryan (2002), pp. 3-325–3-326.
  20. ↑ Acomb and LeBoeuf (2008), p. 12-236.
  21. ↑ 21.0 21.1 21.2 21.3 21.4 Johnson and Price (2008), p. 12-222.
  22. ↑ Denlinger (2008), p. 12-75.
  23. ↑ 23.0 23.1 Comly (2008), pp. 11-42–11-43.
  24. ↑ Johnson and Price (2008), p. 12-221.
  25. ↑ Granito (2008), p. 12-5.
  26. ↑ Granito (2008), p. 12-8.
  27. ↑ Keough and Grill (2005), p. 13.
  28. ↑ 28.0 28.1 Johnson and Price (2008), p. 12-219.
  29. ↑ Cline (2008), p. 12-37.
  30. ↑ 30.0 30.1 Cline (2008), p. 12-36.
  31. ↑ Krakeel (2008), pp. 13-153–13-154.
  32. ↑ National Research Council of Canada et al. (2005), pp. 1.9-1–1.9-2.
  33. ↑ National Research Council of Canada et al. (2005), p. 1.9-7.
  34. ↑ National Research Council of Canada et al. (2005), pp. 2.9-2–2.9-5.
  35. ↑ Australian Building Codes Board (2022), p. 15.
  36. ↑ Australian Building Codes Board (2020b), p. 92.
  37. ↑ Ministry of Business, Innovation and Employment (2013), p. 73.
  38. ↑ Van Rossum (2027), §9.3 (How a zone model works).
  39. ↑ Nowlen et al. (2005b), pp. P-8–P-9.
  40. ↑ Hyslop et al. (2010), pp. 14-2, 14-5–14-6.
  41. ↑ Hyslop et al. (2010), p. 14-7.
  42. ↑ Hyslop et al. (2010), p. 14-11.
  43. ↑ Hyslop et al. (2010), p. 14-8.
  44. ↑ Johnson and Price (2008), pp. 12-228–12-229.
  45. ↑ Granito (2008), p. 12-7.
  46. ↑ Hall and Cote (2008), p. 3-27.

References

  • Acomb, D. J., & LeBoeuf, R. M. (2008). Fire rescue stations and fire service training centers. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-233–12-251). National Fire Protection Association.
  • Australian Building Codes Board. (2020b). Handbook: Fire Safety Verification Method (Print version 1.1).
  • Australian Building Codes Board. (2022). Fire Safety Verification Method Standard 2022.
  • Bryan, J. L. (2002). Behavioral response to fire and smoke. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 3-315–3-341). National Fire Protection Association; Society of Fire Protection Engineers.
  • Cline, D. (2008). Organizational benchmarking and performance evaluation. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-23–12-40). National Fire Protection Association.
  • Comly, A. M., Jr. (2008). Building and site planning for fire safety. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 11-39–11-45). National Fire Protection Association.
  • Custer, R. L. P., & Sheppard, D. T. (2008). Fire loss investigation. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-31–3-41). National Fire Protection Association.
  • Denlinger, R. F. (2008). Managing fire-rescue departments. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-51–12-78). National Fire Protection Association.
  • Granito, J. A. (2008). Planning for public fire-rescue protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-3–12-22). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Hyslop, J. S., Kratchman, J., Siu, N., Afshar, C., Najafi, B., Joglar, F., Li, Y., Henneke, D., & Warner, M. (2010). Fire probabilistic risk assessment methods enhancements: Supplement 1 to NUREG/CR-6850 and EPRI 1011989 (NUREG/CR-6850, Supplement 1; EPRI 1019259). Electric Power Research Institute; U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research.
  • Johnson, R., & Price, M. (2008). GIS for fire station locations and response protocols. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-215–12-231). National Fire Protection Association.
  • Keough, R. J., & Grill, R. A. (2005). Fire alarm systems (NIST NCSTAR 1-4C). National Institute of Standards and Technology.
  • Krakeel, J. J. (2008). Emergency medical services and the fire department. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-145–13-161). National Fire Protection Association.
  • Ministry of Business, Innovation and Employment. (2013). Commentary for Building Code clauses C1–C6 and Verification Method C/VM2.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Nowlen, S. P., Najafi, B., Wyant, F. J., Forester, J., Kazarians, M., Kolaczkowski, A., Joglar, F., Funk, D., Hannaman, G., & Anoba, R. (2005b). EPRI/NRC-RES fire PRA methodology for nuclear power facilities: Vol. 2. Detailed methodology (NUREG/CR-6850; EPRI 1011989). Electric Power Research Institute; U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research.