Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
m Remove source references from file description |
||
| Line 1: | Line 1: | ||
== Summary == | == Summary == | ||
F-N curves per fire for the worked example: reference system A, proposed system B, and system A with twice the fire starts and twice the people exposed | F-N curves per fire for the worked example: reference system A, proposed system B, and system A with twice the fire starts and twice the people exposed. | ||
Original illustration for [[Societal risk]], level 4 Expert. | Original illustration for [[Societal risk]], level 4 Expert. | ||
* Alt text: Log-log F-N chart with three step curves: A at 0.1 up to 2 people, B at 0.3 up to 2 people, A doubled at 0.2 up to 4 people. | * Alt text: Log-log F-N chart with three step curves: A at 0.1 up to 2 people, B at 0.3 up to 2 people, A doubled at 0.2 up to 4 people. | ||
== Licensing == | == Licensing == | ||
New drawing by Fire Safety Academy. © Fire Safety Academy. | New drawing by Fire Safety Academy. © Fire Safety Academy. | ||
Latest revision as of 09:27, 13 November 2026
Summary
F-N curves per fire for the worked example: reference system A, proposed system B, and system A with twice the fire starts and twice the people exposed.
Original illustration for Societal risk, level 4 Expert.
- Alt text: Log-log F-N chart with three step curves: A at 0.1 up to 2 people, B at 0.3 up to 2 people, A doubled at 0.2 up to 4 people.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:43, 2 November 2026 | 900 × 600 (10 KB) | Jan (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.