Ship fire division classes: A-class keeps integrity for 60 minutes and B-class for 30 minutes; the number is the time the average temperature rise on the cold side stays within 140 °C. Based on Eberly (2008), pp. 21-171–21-172.
Ship fire division classes: A-class keeps integrity for 60 minutes and B-class for 30 minutes; the number is the time the average temperature rise on the cold side stays within 140 °C.


Original illustration for [[Ship fire]].
Original illustration for [[Ship fire]].

Latest revision as of 09:25, 13 November 2026

Summary

Ship fire division classes: A-class keeps integrity for 60 minutes and B-class for 30 minutes; the number is the time the average temperature rise on the cold side stays within 140 °C.

Original illustration for Ship fire.

  • Alt text: Diagram of ship fire divisions A-0, A-15, A-30, A-60, B-0 and B-15 with integrity and insulation times and relative insulation thickness