Skip to content

File:Fse-restrained-thermal-expansion-v4.svg: Difference between revisions

From Fire Safety Academy Wiki
Jan (talk | contribs)
Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
 
Mark (talk | contribs)
m Remove source references from file description
 
Line 1: Line 1:
== Summary ==
== Summary ==
Beam temperature at each failure event in NIST's finite element model of the north-east floor framing of WTC 7, compared with the ASTM E119 average steel temperatures of 538 °C (columns) and 593 °C (floor beams). Based on McAllister et al. (2008), p. 353, and National Institute of Standards and Technology (2008), p. 21.
Beam temperature at each failure event in NIST's finite element model of the north-east floor framing of WTC 7, compared with the ASTM E119 average steel temperatures of 538 °C (columns) and 593 °C (floor beams).


Original illustration for [[Restrained thermal expansion]], level 4 Expert.
Original illustration for [[Restrained thermal expansion]], level 4 Expert.


* Source basis: McAllister et al. (2008), p. 353 (Table 8–2), pp. 350 and 352 (model description: north-east corner, beams to 600 °C, girder to 500 °C, slab not heated); National Institute of Standards and Technology (2008), p. 21 (ASTM E119 criteria)
* Alt text: Dot plot of eight failure events in a heated floor model, starting at 103 °C, with reference lines at 538 °C and 593 °C.
* Alt text: Dot plot of eight failure events in a heated floor model, starting at 103 °C, with reference lines at 538 °C and 593 °C.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:23, 13 November 2026

Summary

Beam temperature at each failure event in NIST's finite element model of the north-east floor framing of WTC 7, compared with the ASTM E119 average steel temperatures of 538 °C (columns) and 593 °C (floor beams).

Original illustration for Restrained thermal expansion, level 4 Expert.

  • Alt text: Dot plot of eight failure events in a heated floor model, starting at 103 °C, with reference lines at 538 °C and 593 °C.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current17:26, 2 November 2026Thumbnail for version as of 17:26, 2 November 2026900 × 600 (10 KB)Jan (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata