Skip to content

File:Fse-progressive-collapse-v3.svg: Difference between revisions

From Fire Safety Academy Wiki
Jan (talk | contribs)
Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
 
Mark (talk | contribs)
m Remove source references from file description
 
Line 1: Line 1:
== Summary ==
== Summary ==
Collapse initiation in WTC 7. Left: on Floor 13 the heated east floor beams expand and push the girder between Columns 79 and 44 off its support. Right: falling floors leave Column 79 unbraced over nine storeys and it buckles. Based on National Institute of Standards and Technology (2008), pp. 6, 22 and 53–54.
Collapse initiation in WTC 7. Left: on Floor 13 the heated east floor beams expand and push the girder between Columns 79 and 44 off its support. Right: falling floors leave Column 79 unbraced over nine storeys and it buckles.


Original illustration for [[Progressive collapse]], level 4 Expert.
Original illustration for [[Progressive collapse]], level 4 Expert.


* Source basis: National Institute of Standards and Technology (2008), p. 6 (Figure 1–5, typical floor with column numbering: redraw, do not copy), p. 22 (girder between Columns 79 and 44 pushed west on Floor 13, cascade to Floor 5, eastward buckling), p. 53 (about 15 m spans, thermal elongation, simple shear connections), p. 54 (one-sided framing, no shear studs on the girder, Column 79 without lateral support for nine floors)
* Alt text: Plan of a WTC 7 floor corner where expanding beams push a girder off Column 79, and an elevation of Column 79 buckling after the floors fell.
* Alt text: Plan of a WTC 7 floor corner where expanding beams push a girder off Column 79, and an elevation of Column 79 buckling after the floors fell.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:20, 13 November 2026

Summary

Collapse initiation in WTC 7. Left: on Floor 13 the heated east floor beams expand and push the girder between Columns 79 and 44 off its support. Right: falling floors leave Column 79 unbraced over nine storeys and it buckles.

Original illustration for Progressive collapse, level 4 Expert.

  • Alt text: Plan of a WTC 7 floor corner where expanding beams push a girder off Column 79, and an elevation of Column 79 buckling after the floors fell.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.