The same 340 kW fire (characteristic diameter about 0.62 m) on grids of 0.2 m, 0.1 m and 0.05 m cells | The same 340 kW fire (characteristic diameter about 0.62 m) on grids of 0.2 m, 0.1 m and 0.05 m cells. | ||
Original illustration for [[Mesh resolution]], level 4 Expert. | Original illustration for [[Mesh resolution]], level 4 Expert. | ||
* Alt text: Three grids over the same fire: the fire spans about 3 cells of 0.2 m, 6 cells of 0.1 m and 12 cells of 0.05 m. | * Alt text: Three grids over the same fire: the fire spans about 3 cells of 0.2 m, 6 cells of 0.1 m and 12 cells of 0.05 m. | ||
== Licensing == | == Licensing == | ||
New drawing by Fire Safety Academy. © Fire Safety Academy. | New drawing by Fire Safety Academy. © Fire Safety Academy. | ||
Latest revision as of 09:14, 13 November 2026
Summary
The same 340 kW fire (characteristic diameter about 0.62 m) on grids of 0.2 m, 0.1 m and 0.05 m cells.
Original illustration for Mesh resolution, level 4 Expert.
- Alt text: Three grids over the same fire: the fire spans about 3 cells of 0.2 m, 6 cells of 0.1 m and 12 cells of 0.05 m.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:36, 2 November 2026 | 900 × 600 (13 KB) | Jan (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
You cannot overwrite this file.
File usage
The following page uses this file: