Hand calculation of evacuation time for 300 people and four stairs: the 1.6 m stairs govern, giving 5 + 63 + 10 = 78 s. Based on Van Rossum (2027), §7.5.
Hand calculation of evacuation time for 300 people and four stairs: the 1.6 m stairs govern, giving 5 + 63 + 10 = 78 s.


Original vector illustration for [[Exit capacity]], level 2 Intermediate.
Original vector illustration for [[Exit capacity]], level 2 Intermediate.


* Source basis: Van Rossum (2027), §7.5 (worked example; redraw, do not copy)
* Alt text: Plan of a hall with 300 people and four stairs, 75 people each; a timeline adds 5 s walking, 63 s flow time and 10 s walking to 78 s.
* Alt text: Plan of a hall with 300 people and four stairs, 75 people each; a timeline adds 5 s walking, 63 s flow time and 10 s walking to 78 s.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 08:55, 13 November 2026

Summary

Hand calculation of evacuation time for 300 people and four stairs: the 1.6 m stairs govern, giving 5 + 63 + 10 = 78 s.

Original vector illustration for Exit capacity, level 2 Intermediate.

  • Alt text: Plan of a hall with 300 people and four stairs, 75 people each; a timeline adds 5 s walking, 63 s flow time and 10 s walking to 78 s.